Test Report issued under the responsibility of: TEST REPORT IEC 61347-2-13 Part 2: Particular requirements: Section Thirteen – d.c. or a.c. supplied electronic controlgear for LED modules Report Number. ............................. : 11038964 003 Date of issue .................................. : 18 Nov., 2016 Total number of pages .................... 7 Applicant’s name ........................... : MEAN WELL Enterprises Co Ltd. Address .......................................... : No.28, Wuquan 3rd Rd., Wugu Dist., New Taipei City 248, Taiwan Test specification: Standard ......................................... : IEC 61347-2-13:2006 (First Edition) used in conjunction with IEC 61347-1:2007 (Second Edition) + A1:2010 + A2:2012 Test procedure ............................... : CB Scheme Non-standard test method...........: N/A Test Report Form No. .................... : IEC61347_2_13D Test Report Form(s) Originator .... : Intertek Semko AB Master TRF ..................................... : 2013-10 Copyright © 2013 Worldwide System for Conformity Testing and Certification of Electrotechnical Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. Test item description .................... : Independent Controlgear Trade Mark ..................................... : Manufacturer .................................. : Same as applicant. Model/Type reference.................... : HLG-240x-yz (x= H or blank, y= 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= A, B, AB or blank) Ratings............................................ : I/P: AC 100-240V, 50/60Hz, 4.0A O/P: See page 7 for details ta = 50° C, tc= 90° C IP65 for models HLG-240x-yz (x= H or blank, y = 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= A or AB); IP67 for models HLG-240x-yz (x= H or blank, y = 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= B or blank) IP68 for models HLG-240x-yz (x= H or blank, y = 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= B or blank) Page 3 of 7 Report No. 11038964 003 TRF No. IEC61347_2_13D List of Attachments (including a total number of pages in each attachment): - N/A Summary of testing: See below for details. Tests performed (name of test and test clause): N/A Testing location: N/A Summary of compliance with National Differences: List of countries addressed: EU Group Differences, AT, SE, DK Explanation of used codes: AT = Austria, DK = Denmark, SE = Sweden. The product fulfils the requirements of EN 61347-2-13:2006 which used in conjunction with EN 61347- 1:2008+A1:2011+A2:2013. Page 4 of 7 Report No. 11038964 003 TRF No. IEC61347_2_13D Copy of marking plate N/A Page 5 of 7 Report No. 11038964 003 TRF No. IEC61347_2_13D Test item particulars .............................................. : Classification of installation and use ........................ : Class I Independent SELV Controlgear Supply Connection ................................................... : Lead wires/Cable .................................................................................. : .................................................................................. : Possible test case verdicts: - test case does not apply to the test object ............. : N/A - test object does meet the requirement ................... : P (Pass) - test object does not meet the requirement ............. : F (Fail) Testing ..................................................................... : Date of receipt of test item ........................................ : N/A Date (s) of performance of tests ............................... : N/A General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator. Clause numbers between brackets refer to clauses in IEC 61347-1 Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02: The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided .............................................................. : Yes Not applicable When differences exist; they shall be identified in the General product information section. Name and address of factory (ies) ....................... : 1) MEAN WELL Enterprises Co., Ltd. No. 28, Wuquan 3rd Rd., Wugu Dist., New Taipei City 248, Taiwan 2) SuZhou MEAN WELL Technology Co., Ltd. No. 77, Jian-min Road, Dong-qiao, Pan-yang Ind. Park, Huang-dai Town, Xiang-cheng District, Suzhou, Jiangsu 215152, P. R. China 3) MEAN WELL (GUANGZHOU) ELECTRONICS CO., LTD HUADU BRANCH. No.11 Jingu South Road, Huadong Town, Huadu District, Guangzhou 510890, P. R. China Page 6 of 7 Report No. 11038964 003 TRF No. IEC61347_2_13D General product information: See report 11038964 001-002 for details. Description of change(s): 1. Add new factory as follows. - MEAN WELL (GUANGZHOU) ELECTRONICS CO., LTD HUADU BRANCH No.11 Jingu South Road, Huadong Town, Huadu District, Guangzhou 510890, P. R. China 2. Delete factory, see below. - Mean Well (GUANGZHOU) Electroncis Co Ltd 2 nd Floor, No. A Building, Yuean Ind. Park, Dongpu Town, TianHe Dist., Guangzhou, P.R. China For the above described change(s) the following was considered to be necessary: Change Testing Comments 1. • N/A - Detail refer to “Name and address of factory” was marked in bold type. 2. • N/A No safety impact. Definition of variable(s): Variable: Range of variable: Content: x H or blank H: Additional input rating for US (for reference only in this report). Blank: No additional input ratings. y 12, 15, 20, 24, 30, 36, 42, 48, 54 Stand for different output ratings. z A, B, AB or blank Stand for different input/output connection type. z= A: AC wire and output has one set output cord, two openings with plastic objects on the top enclosure and IP65 provided. z= B: AC wire and output has two set output cords (one is for adjust current load), no opening on the enclosure and IP67 or IP68 provided. z= AB: AC wire and output has two set output cords (one is for adjust current load), with plastic objects on the top enclosure and IP65 provided. z= blank: AC wire and output has one set output cord, no opening on the enclosure and IP67 or IP68 provided. History of amendments and modifications: Ref. No. 11038964 001, dated 28 Nov., 2014 (original test report) Ref. No. 11038964 002, dated 10 Dec., 2015 (modification) Ref. No. 11038964 003, dated 18 Nov., 2016 (amendment) Page 7 of 7 Report No. 11038964 003 TRF No. IEC61347_2_13D Input and Output ratings: Model No. Input rating Output rating HLG-240-12, HLG-240-12A, HLG-240-12B 100-240V ac, 4.0A, 50/60Hz +12Vdc, 16A HLG-240H-12, HLG-240H-12A, HLG-240H-12B, HLG-240H-12AB 100- 240Vac, 4.0A, 50/60Hz +12Vdc, 16A HLG-240-15, HLG-240-15A, HLG-240-15B 100- 240Vac, 4.0A, 50/60Hz +15Vdc, 15A HLG-240H-15, HLG-240H-15A, HLG-240H-15B, HLG-240H-15AB 100- 240Vac, 4.0A, 50/60Hz +15Vdc, 15A HLG-240-20, HLG-240-20A,HLG-240-20B 100- 240Vac, 4.0A, 50/60Hz +20Vdc, 12A HLG-240H-20, HLG-240H-20A, HLG-240H-20B, HLG-240H-20AB 100- 240Vac, 4.0A, 50/60Hz +20Vdc, 12A HLG-240-24, HLG-240-24A, HLG-240-24B 100- 240Vac, 4.0A, 50/60Hz +24Vdc, 10A HLG-240H-24, HLG-240H-24A, HLG-240H-24B, HLG-240H-24AB 100- 240Vac, 4.0A, 50/60Hz +24Vdc, 10A HLG-240-30, HLG-240-30A, HLG-240-30B 100- 240Vac, 4.0A, 50/60Hz +30Vdc, 8A HLG-240H-30, HLG-240H-30A, HLG-240H-30B, HLG-240H-30AB 100- 240Vac, 4.0A, 50/60Hz +30Vdc, 8A HLG-240-36, HLG-240-36A, HLG-240-36B 100- 240V, 4.0A, 50/60Hz +36Vdc, 6.7A HLG-240H-36, HLG-240H-36A, HLG-240H-36B, HLG-240H-36AB 100- 240V, 4.0A, 50/60Hz +36Vdc, 6.7A HLG-240-42, HLG-240-42A, HLG-240-42B 100- 240Vac, 4.0A, 50/60Hz +42Vdc, 5.72A HLG-240H-42, HLG-240H-42A, HLG-240H-42B, HLG-240H-42AB 100-240Vac, 4.0A, 50/60 Hz +42Vdc, 5.72A HLG-240-48, HLG-240-48A, HLG-240-48B 100- 240Vac, 4.0A, 50/60Hz +48Vdc, 5A HLG-240H-48, HLG-240H-48A, HLG-240H-48B, HLG-240H-48AB 100- 240Vac, 4.0A, 50/60Hz +48Vdc, 5A HLG-240-54, HLG-240-54A, HLG-240-54B 100- 240Vac, 4.0A, 50/60Hz +54Vdc, 4.45A HLG-240H-54, HLG-240H-54A, HLG-240H-54B, HLG-240H-54AB 100-240Vac, 4.0A, 50/60Hz +54Vdc, 4.45A Test Report issued under the responsibility of: TEST REPORT IEC 61347-2-13 Part 2: Particular requirements: Section Thirteen – d.c. or a.c. supplied electronic controlgear for LED modules Report Number. ............................. : 11038964 002 Date of issue .................................. : 10 Dec., 2015 Total number of pages .................... 26 Applicant’s name ........................... : Mean Well Enterprises Co Ltd. Address .......................................... : No.28, Wuquan 3rd Rd., Wugu Dist., New Taipei City 248, Taiwan Test specification: Standard ......................................... : IEC 61347-2-13:2006 (First Edition) used in conjunction with IEC 61347-1:2007 (Second Edition) + A1:2010 + A2:2012 Test procedure ............................... : CB Scheme Non-standard test method...........: N/A Test Report Form No. .................... : IEC61347_2_13D Test Report Form(s) Originator .... : Intertek Semko AB Master TRF ..................................... : 2013-10 Copyright © 2013 Worldwide System for Conformity Testing and Certification of Electrotechnical Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. Test item description .................... : Independent Controlgear Trade Mark ..................................... : Manufacturer .................................. : Same as applicant. Model/Type reference.................... : HLG-240x-yz (x= H or blank, y= 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= A, B, AB or blank) Ratings............................................ : I/P: AC 100-240V, 50/60Hz, 4.0A O/P: see page 14 for details ta = 50° C, tc= 90° C IP65 for models HLG-240x-yz (x= H or blank, y = 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= A or AB); IP67 for models HLG-240x-yz (x= H or blank, y = 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= B or blank) IP68 for models HLG-240x-yz (x= H or blank, y = 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= B or blank) Page 3 of 26 Report No.: 11038964 002 TRF No. IEC61347_2_13D List of Attachments (including a total number of pages in each attachment): - N/A Summary of testing: See below for details. Tests performed (name of test and test clause): • The main part of independent controlgear except for lead wires bare parts was investigated and test results found in compliance with IP68 test (for models HLG- 240x-yz (x= H or blank, y= 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= B or blank)) of standard IEC 60529:2001 requirement which test by TÜV Rheinland, the details models with IP68 see copy of marking plate. Testing location: All tests as described in Test Case and Measurement Sections were performed at the laboratory described on previous page. Summary of compliance with National Differences: List of countries addressed: EU Group Differences, AT, SE, DK Explanation of used codes: AT = Austria, DK = Denmark, SE = Sweden. The product fulfils the requirements of EN 61347-2-13:2006 which used in conjunction with EN 61347- 1:2008+A1:2011+A2:2013. Copy of marking plate Page 4 of 26 Report No.: 11038964 002 TRF No. IEC61347_2_13D Copy of marking plate Page 5 of 26 Report No.: 11038964 002 TRF No. IEC61347_2_13D Copy of marking plate Page 6 of 26 Report No.: 11038964 002 TRF No. IEC61347_2_13D Copy of marking plate Page 7 of 26 Report No.: 11038964 002 TRF No. IEC61347_2_13D Copy of marking plate Page 8 of 26 Report No.: 11038964 002 TRF No. IEC61347_2_13D Copy of marking plate Page 9 of 26 Report No.: 11038964 002 TRF No. IEC61347_2_13D Copy of marking plate