Test Report issued under the responsibility of: TEST REPORT IEC 61347-2-13 Part 2: Particular requirements: Section Thirteen – d.c. or a.c. supplied electronic controlgear for LED modules Report Number. ............................. : 11038964 003 Date of issue .................................. : 18 Nov., 2016 Total number of pages .................... 7 Applicant’s name ........................... : MEAN WELL Enterprises Co Ltd. Address .......................................... : No.28, Wuquan 3rd Rd., Wugu Dist., New Taipei City 248, Taiwan Test specification: Standard ......................................... : IEC 61347-2-13:2006 (First Edition) used in conjunction with IEC 61347-1:2007 (Second Edition) + A1:2010 + A2:2012 Test procedure ............................... : CB Scheme Non-standard test method………..: N/A Test Report Form No. .................... : IEC61347_2_13D Test Report Form(s) Originator .... : Intertek Semko AB Master TRF ..................................... : 2013-10 Copyright © 2013 Worldwide System for Conformity Testing and Certification of Electrotechnical Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. Test item description .................... : Independent Controlgear Trade Mark ..................................... : Manufacturer .................................. : Same as applicant. Model/Type reference.................... : HLG-240x-yz (x= H or blank, y= 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= A, B, AB or blank) Ratings............................................ : I/P: AC 100-240V, 50/60Hz, 4.0A O/P: See page 7 for details ta = 50°C, tc= 90°C IP65 for models HLG-240x-yz (x= H or blank, y = 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= A or AB); IP67 for models HLG-240x-yz (x= H or blank, y = 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= B or blank) IP68 for models HLG-240x-yz (x= H or blank, y = 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= B or blank) Page 3 of 7 Report No. 11038964 003 List of Attachments (including a total number of pages in each attachment): - N/A Summary of testing: See below for details. Tests performed (name of test and test clause): Testing location: N/A N/A Summary of compliance with National Differences: List of countries addressed: EU Group Differences, AT, SE, DK Explanation of used codes: AT = Austria, DK = Denmark, SE = Sweden. The product fulfils the requirements of EN 61347-2-13:2006 which used in conjunction with EN 61347- 1:2008+A1:2011+A2:2013. TRF No. IEC61347_2_13D Page 4 of 7 Report No. 11038964 003 Copy of marking plate N/A TRF No. IEC61347_2_13D Page 5 of 7 Report No. 11038964 003 Test item particulars .............................................. : Classification of installation and use ........................ : Class I Independent SELV Controlgear Supply Connection ................................................... : Lead wires/Cable .................................................................................. : .................................................................................. : Possible test case verdicts: - test case does not apply to the test object ............. : N/A - test object does meet the requirement ................... : P (Pass) - test object does not meet the requirement ............. : F (Fail) Testing ..................................................................... : Date of receipt of test item ........................................ : N/A Date (s) of performance of tests ............................... : N/A General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator. Clause numbers between brackets refer to clauses in IEC 61347-1 Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02: The application for obtaining a CB Test Certificate Yes includes more than one factory location and a Not applicable declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided .............................................................. : When differences exist; they shall be identified in the General product information section. Name and address of factory (ies) ....................... : 1) MEAN WELL Enterprises Co., Ltd. No. 28, Wuquan 3rd Rd., Wugu Dist., New Taipei City 248, Taiwan 2) SuZhou MEAN WELL Technology Co., Ltd. No. 77, Jian-min Road, Dong-qiao, Pan-yang Ind. Park, Huang-dai Town, Xiang-cheng District, Suzhou, Jiangsu 215152, P. R. China 3) MEAN WELL (GUANGZHOU) ELECTRONICS CO., LTD HUADU BRANCH. No.11 Jingu South Road, Huadong Town, Huadu District, Guangzhou 510890, P. R. China TRF No. IEC61347_2_13D Page 6 of 7 Report No. 11038964 003 General product information: See report 11038964 001-002 for details. Description of change(s): 1. Add new factory as follows. - MEAN WELL (GUANGZHOU) ELECTRONICS CO., LTD HUADU BRANCH No.11 Jingu South Road, Huadong Town, Huadu District, Guangzhou 510890, P. R. China 2. Delete factory, see below. - Mean Well (GUANGZHOU) Electroncis Co Ltd nd 2 Floor, No. A Building, Yuean Ind. Park, Dongpu Town, TianHe Dist., Guangzhou, P.R. China For the above described change(s) the following was considered to be necessary: Change Testing Comments 1. • N/A - Detail refer to “Name and address of factory” was marked in bold type. 2. • N/A No safety impact. Definition of variable(s): Variable: Range of variable: Content: x H or blank H: Additional input rating for US (for reference only in this report). Blank: No additional input ratings. y 12, 15, 20, 24, 30, 36, 42, 48, Stand for different output ratings. 54 z A, B, AB or blank Stand for different input/output connection type. z= A: AC wire and output has one set output cord, two openings with plastic objects on the top enclosure and IP65 provided. z= B: AC wire and output has two set output cords (one is for adjust current load), no opening on the enclosure and IP67 or IP68 provided. z= AB: AC wire and output has two set output cords (one is for adjust current load), with plastic objects on the top enclosure and IP65 provided. z= blank: AC wire and output has one set output cord, no opening on the enclosure and IP67 or IP68 provided. History of amendments and modifications: Ref. No. 11038964 001, dated 28 Nov., 2014 (original test report) Ref. No. 11038964 002, dated 10 Dec., 2015 (modification) Ref. No. 11038964 003, dated 18 Nov., 2016 (amendment) TRF No. IEC61347_2_13D Page 7 of 7 Report No. 11038964 003 Input and Output ratings: Model No. Input rating Output rating HLG-240-12, HLG-240-12A, HLG-240-12B 100-240Vac, 4.0A, 50/60Hz +12Vdc, 16A HLG-240H-12, HLG-240H-12A, HLG-240H-12B, 100-240Vac, 4.0A, 50/60Hz +12Vdc, 16A HLG-240H-12AB HLG-240-15, HLG-240-15A, HLG-240-15B 100-240Vac, 4.0A, 50/60Hz +15Vdc, 15A HLG-240H-15, HLG-240H-15A, HLG-240H-15B, 100-240Vac, 4.0A, 50/60Hz +15Vdc, 15A HLG-240H-15AB HLG-240-20, HLG-240-20A,HLG-240-20B 100-240Vac, 4.0A, 50/60Hz +20Vdc, 12A HLG-240H-20, HLG-240H-20A, HLG-240H-20B, 100-240Vac, 4.0A, 50/60Hz +20Vdc, 12A HLG-240H-20AB HLG-240-24, HLG-240-24A, HLG-240-24B 100-240Vac, 4.0A, 50/60Hz +24Vdc, 10A HLG-240H-24, HLG-240H-24A, HLG-240H-24B, 100-240Vac, 4.0A, 50/60Hz +24Vdc, 10A HLG-240H-24AB HLG-240-30, HLG-240-30A, HLG-240-30B 100-240Vac, 4.0A, 50/60Hz +30Vdc, 8A HLG-240H-30, HLG-240H-30A, HLG-240H-30B, 100-240Vac, 4.0A, 50/60Hz +30Vdc, 8A HLG-240H-30AB HLG-240-36, HLG-240-36A, HLG-240-36B 100-240V, 4.0A, 50/60Hz +36Vdc, 6.7A HLG-240H-36, HLG-240H-36A, HLG-240H-36B, 100-240V, 4.0A, 50/60Hz +36Vdc, 6.7A HLG-240H-36AB HLG-240-42, HLG-240-42A, HLG-240-42B 100-240Vac, 4.0A, 50/60Hz +42Vdc, 5.72A HLG-240H-42, HLG-240H-42A, HLG-240H-42B, 100-240Vac, 4.0A, 50/60Hz +42Vdc, 5.72A HLG-240H-42AB HLG-240-48, HLG-240-48A, HLG-240-48B 100-240Vac, 4.0A, 50/60Hz +48Vdc, 5A HLG-240H-48, HLG-240H-48A, HLG-240H-48B, 100-240Vac, 4.0A, 50/60Hz +48Vdc, 5A HLG-240H-48AB HLG-240-54, HLG-240-54A, HLG-240-54B 100-240Vac, 4.0A, 50/60Hz +54Vdc, 4.45A HLG-240H-54, HLG-240H-54A, HLG-240H-54B, 100-240Vac, 4.0A, 50/60Hz +54Vdc, 4.45A HLG-240H-54AB TRF No. IEC61347_2_13D Test Report issued under the responsibility of: TEST REPORT IEC 61347-2-13 Part 2: Particular requirements: Section Thirteen – d.c. or a.c. supplied electronic controlgear for LED modules Report Number. ............................. : 11038964 002 Date of issue .................................. : 10 Dec., 2015 Total number of pages .................... 26 Applicant’s name ........................... : Mean Well Enterprises Co Ltd. Address .......................................... : No.28, Wuquan 3rd Rd., Wugu Dist., New Taipei City 248, Taiwan Test specification: Standard ......................................... : IEC 61347-2-13:2006 (First Edition) used in conjunction with IEC 61347-1:2007 (Second Edition) + A1:2010 + A2:2012 Test procedure ............................... : CB Scheme Non-standard test method………..: N/A Test Report Form No. .................... : IEC61347_2_13D Test Report Form(s) Originator .... : Intertek Semko AB Master TRF ..................................... : 2013-10 Copyright © 2013 Worldwide System for Conformity Testing and Certification of Electrotechnical Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. Test item description .................... : Independent Controlgear Trade Mark ..................................... : Manufacturer .................................. : Same as applicant. Model/Type reference.................... : HLG-240x-yz (x= H or blank, y= 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= A, B, AB or blank) Ratings............................................ : I/P: AC 100-240V, 50/60Hz, 4.0A O/P: see page 14 for details ta = 50°C, tc= 90°C IP65 for models HLG-240x-yz (x= H or blank, y = 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= A or AB); IP67 for models HLG-240x-yz (x= H or blank, y = 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= B or blank) IP68 for models HLG-240x-yz (x= H or blank, y = 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= B or blank) Page 3 of 26 Report No.: 11038964 002 List of Attachments (including a total number of pages in each attachment): - N/A Summary of testing: See below for details. Tests performed (name of test and test clause): Testing location: • The main part of independent controlgear All tests as described in Test Case and except for lead wires bare parts was Measurement Sections were performed at the investigated and test results found in laboratory described on previous page. compliance with IP68 test (for models HLG- 240x-yz (x= H or blank, y= 12, 15, 20, 24, 30, 36, 42, 48 or 54; z= B or blank)) of standard IEC 60529:2001 requirement which test by TÜV Rheinland, the details models with IP68 see copy of marking plate. Summary of compliance with National Differences: List of countries addressed: EU Group Differences, AT, SE, DK Explanation of used codes: AT = Austria, DK = Denmark, SE = Sweden. The product fulfils the requirements of EN 61347-2-13:2006 which used in conjunction with EN 61347- 1:2008+A1:2011+A2:2013. Copy of marking plate TRF No. IEC61347_2_13D Page 4 of 26 Report No.: 11038964 002 Copy of marking plate TRF No. IEC61347_2_13D Page 5 of 26 Report No.: 11038964 002 Copy of marking plate TRF No. IEC61347_2_13D Page 6 of 26 Report No.: 11038964 002 Copy of marking plate TRF No. IEC61347_2_13D Page 7 of 26 Report No.: 11038964 002 Copy of marking plate TRF No. IEC61347_2_13D Page 8 of 26 Report No.: 11038964 002 Copy of marking plate TRF No. IEC61347_2_13D Page 9 of 26 Report No.: 11038964 002 Copy of marking plate TRF No. IEC61347_2_13D Page 10 of 26 Report No.: 11038964 002 Copy of marking plate TRF No. IEC61347_2_13D Page 11 of 26 Report No.: 11038964 002 Test item particulars .............................................. : Classification of installation and use ........................ : Class I Independent SELV Controlgear Supply Connection ................................................... : Lead wires/Cable .................................................................................. : .................................................................................. : Possible test case verdicts: - test case does not apply to the test object ............. : N/A - test object does meet the requirement ................... : P (Pass) - test object does not meet the requirement ............. : F (Fail) Testing ..................................................................... : Date of receipt of test item ........................................ : Oct. 02., 2015 Date (s) of performance of tests ............................... : Oct. 20, 2015 to Nov. 20, 2015 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator. Clause numbers between brackets refer to clauses in IEC 61347-1 Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02: The application for obtaining a CB Test Certificate Yes includes more than one factory location and a Not applicable declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided .............................................................. : When differences exist; they shall be identified in the General product information section. Name and address of factory (ies) ....................... : 1) Mean Well Enterprises Co., Ltd. No. 28, Wuquan 3rd Rd., Wugu Dist., New Taipei City 248, Taiwan 2) SuZhou Mean Well Technology Co., Ltd. No. 77, Jian-min Road, Dong-qiao, Pan-yang Ind. Park, Huang-dai Town, Xiang-cheng District, Suzhou, Jiangsu 215152, P. R. China 3) Mean Well (GUANGZHOU) Electroncis Co Ltd 2nd Floor, No. A Building, Yuean Ind. Park, Dongpu Town, TianHe Dist., Guangzhou, P.R. China TRF No. IEC61347_2_13D Page 12 of 26 Report No.: 11038964 002 General product information: The controlgears shall be installed inside of the luminaire completely when the input insulation wire/cable with nominal cross-sectional area 0.75mm2 min.. For details see Table ANNEX 1 components. The controlgears were provided for indoor use only when the input insulation cable with nominal cross- sectional area 1.0mm2 min. and marking plate of unit marked IP65, IP67 and IP68. For details see Table ANNEX 1 components. The controlgears maybe intend to outdoor use declaration by manufacturer, while input/output insulation cable with Rubber Cable type which like type H05RN-F, H05RR-F..etc, avoid not correct used. The input insulation wire/cable used Rubber Cable type and nominal cross-sectional area 1.0mm2 min. while marking plate of unit marked IP65, IP67 and IP68 for details see Table ANNEX 1 components. Description of change(s): 1. Delete all marking plate without IP code in report 11038964 001. 2. Add descriptions of general product information. 3. Add new marking plates of models HLG-240H-yz (x=12, 15, 20, 24, 30, 36, 42, 48 or 54; z=A, B or blank) with IP code, which are similar to previously approved models HLG-240H-yz (x=12, 15, 20, 24, 30, 36, 42, 48 or 54; z=A, B or blank) with IP code expect for additional order no. in marking plates. 4. Add new models HLG-240H-yz (x=12, 15, 20, 24, 30, 36, 42, 48 or 54; z=AB) with IP65, which are similar to previously approved models HLG-240H-yz (x=12, 15, 20, 24, 30, 36, 42, 48 or 54; z=B) expect for no opening on top enclosure used. 5. Add new descriptions of “Definition of variable(s)”. 6. Add IP68 test for models HLG-240H-yz (x=12, 15, 20, 24, 30, 36, 42, 48 or 54; z=B or blank). 7. Renew descriptions of input cable/lead wire, output cable/lead wire and dimming cable/lead wire in ANNEX 1: components table. For the above described change(s) the following was considered to be necessary: Change Testing Comments 1. • N/A This changes no impact safety. 2. • N/A For details see above general product information. 3. • N/A See copy of marking plate and appended sub-clause 7.1 (7.1). 4. • N/A See copy of marking plate and appended sub-clause 7.1 (7.1). 5. • N/A See below “Definition of variable(s)” for details. 6. • IPX8 test Because of the equipment were sealed by epoxy-resin which prevented water and dust from ingress. Therefore, the equipment was only performed IPX8 test and passed this test. The IP6X test have been perform in previously approved models HLG-240H-yz (z=A or B). 7. • N/A See details in ANNEX 1: components table. Definition of variable(s): Variable: Range of variable: Content: x H or blank H: Additional input rating for US (for reference only in this report). Blank: No additional input ratings. TRF No. IEC61347_2_13D Page 13 of 26 Report No.: 11038964 002 y 12, 15, 20, 24, 30, 36, 42, 48, Stand for different output ratings. 54 z A, B, AB or blank Stand for different input/output connection type. z= A: AC wire and output has one set output cord, two openings with plastic objects on the top enclosure and IP65 provided. z= B: AC wire and output has two set output cords (one is for adjust current load), no opening on the enclosure and IP67 or IP68 provided. z= AB: AC wire and output has two set output cords (one is for adjust current load), with plastic objects on the top enclosure and IP65 provided. z= blank: AC wire and output has one set output cord, no opening on the enclosure and IP67 or IP68 provided. History of amendments and modifications: Ref. No. 11038964 001, dated 28 Nov., 2014 (original test report) Ref. No. 11038964 002, dated 10 Dec., 2015 (modification) TRF No. IEC61347_2_13D Page 14 of 26 Report No.: 11038964 002 Input and output rating Model No. Input rating Output rating HLG-240-12, HLG-240-12A, HLG-240-12B 100-240Vac, 4.0A, 50/60Hz +12Vdc, 16A HLG-240H-12, HLG-240H-12A, HLG-240H-12B, 100-240Vac, 4.0A, 50/60Hz +12Vdc, 16A HLG-240H-12AB HLG-240-15, HLG-240-15A, HLG-240-15B 100-240Vac, 4.0A, 50/60Hz +15Vdc, 15A HLG-240H-15, HLG-240H-15A, HLG-240H-15B, 100-240Vac, 4.0A, 50/60Hz +15Vdc, 15A HLG-240H-15AB HLG-240-20, HLG-240-20A,HLG-240-20B 100-240Vac, 4.0A, 50/60Hz +20Vdc, 12A HLG-240H-20, HLG-240H-20A, HLG-240H-20B, 100-240Vac, 4.0A, 50/60Hz +20Vdc, 12A HLG-240H-20AB HLG-240-24, HLG-240-24A, HLG-240-24B 100-240Vac, 4.0A, 50/60Hz +24Vdc, 10A HLG-240H-24, HLG-240H-24A, HLG-240H-24B, 100-240Vac, 4.0A, 50/60Hz +24Vdc, 10A HLG-240H-24AB HLG-240-30, HLG-240-30A, HLG-240-30B 100-240Vac, 4.0A, 50/60Hz +30Vdc, 8A HLG-240H-30, HLG-240H-30A, HLG-240H-30B, 100-240Vac, 4.0A, 50/60Hz +30Vdc, 8A HLG-240H-30AB HLG-240-36, HLG-240-36A, HLG-240-36B 100-240V, 4.0A, 50/60Hz +36Vdc, 6.7A HLG-240H-36, HLG-240H-36A, HLG-240H-36B, 100-240V, 4.0A, 50/60Hz +36Vdc, 6.7A HLG-240H-36AB HLG-240-42, HLG-240-42A, HLG-240-42B 100-240Vac, 4.0A, 50/60Hz +42Vdc, 5.72A HLG-240H-42, HLG-240H-42A, HLG-240H-42B, 100-240Vac, 4.0A, 50/60Hz +42Vdc, 5.72A HLG-240H-42AB HLG-240-48, HLG-240-48A, HLG-240-48B 100-240Vac, 4.0A, 50/60Hz +48Vdc, 5A HLG-240H-48, HLG-240H-48A, HLG-240H-48B, 100-240Vac, 4.0A, 50/60Hz +48Vdc, 5A HLG-240H-48AB HLG-240-54, HLG-240-54A, HLG-240-54B 100-240Vac, 4.0A, 50/60Hz +54Vdc, 4.45A HLG-240H-54, HLG-240H-54A, HLG-240H-54B, 100-240Vac, 4.0A, 50/60Hz +54Vdc, 4.45A HLG-240H-54AB TRF No. IEC61347_2_13D Page 15 of 26 Report No.: 11038964 002 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict 7.1 (7.1) Mandatory markings P a) mark of origin See copy of marking plate. P b) model number or type reference See copy of marking plate. P c) symbol for independent controlgear, if Independent Controlgear. P applicable d) correlation between interchangeable parts and No user replaceable / N/A controlgear marked interchangeable parts in the controlgear. e) rated supply voltage (V) See copy of marking plate. P supply frequency (Hz) See copy of marking plate. P supply current (A) See copy of marking plate. P f) earthing symbol IEC 60417-5019 use for P protective earthing, See copy of marking plate. k) wiring diagram See copy of marking plate. P l) value of tc See copy of marking plate. P m) symbol for declared temperature , See copy of marking P plate. Constant voltage type: Yes No - rated output voltage (V) ..................................... : See copy of marking plate. P Constant current type: Yes No - rated output current (A) ...................................... : N/A - rated maximum output voltage (V) .................... : N/A - indication if for LED modules only See installation instruction. P TRF No. IEC61347_2_13D Page 16 of 26 Report No.: 11038964 002 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict ANNEX 1: components P object/part No. code manufacturer/ type/model technical data standard mark(s) of trademark conformity Critical Components Input Lead A/B/ Guangzhou TY 1990 300/500V, Min. DIN 57520 VDE Wire (Single C Tang Yao 18AWG (min. 2 core 0.75 mm ), 3C, conductor) FEP double (internal wire insulation, only used in 180°C inside of final system) 2 Input Cable A/B/ Lucky United H05RR-F, min. 0.75 mm DIN EN 50525- VDE (Only used in C H05RN-F (min. 18AWG), 2-21 inside of final 3C, VW-1, min. system) 300V, min. 100°C 2 A/B/ Lucky United H05RR-F, min. 1.0 mm DIN EN 50525- VDE C H05RN-F, (min. 17AWG), 2-21 H07RN-F 3C, VW-1, min. 300V, min. 100°C 2 (Only used in A/B/ Lucky United H05BB-F, min. 0.75 mm DIN EN 50525- VDE inside of final C H05BN4-F (min. 18AWG), 2-21 system) 3C, VW-1, min. 300V, min. 100°C 2 A/B/ Lucky United H05BB-F, min. 1.0 mm DIN EN 50525- VDE C H05BN4-F (min. 17AWG), 2-21 3C, VW-1, min. 300V, min. 100°C 2 (Only used in A/B/ Guangdong H05RR-F, min. 0.75 mm DIN EN 50525- VDE inside of final C Rifeng H05RN-F (min. 18AWG), 2-21 system) 3C, VW-1, min. 300V, min. 100°C 2 A/B/ Guangdong H05RR-F, min. 1.0 mm DIN EN 50525- VDE C Rifeng H05RN-F (min. 17AWG), 2-21 H07RN-F 3C, VW-1, min. 300V, min. 100°C TRF No. IEC61347_2_13D Page 17 of 26 Report No.: 11038964 002 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict 2 (Only used in A/B/ Dong Guan H05RR-F, min. 0.75 mm DIN EN 50525- VDE inside of final C Recheer H05RN-F (min. 18AWG), 2-21 system) 3C, VW-1, min. 300V, min. 100°C 2 A/B/ Dong Guan H05RR-F, min. 1.0 mm DIN EN 50525- VDE C Recheer H05RN-F, (min. 17AWG), 2-21 H07RN-F 3C, VW-1, min. 300V, min. 100°C 2 (Only used in A/B/ Zheng Yu H05RR-F, min. 0.75 mm DIN EN 50525- VDE inside of final C H05RN-F (min. 18AWG), 2-21 system) 3C, VW-1, min. 300V, min. 100°C 2 A/B/ Zheng Yu H05RR-F, min. 1.0 mm DIN EN 50525- VDE C H05RN-F, (min. 17AWG), 2-21 H07RN-F 3C, VW-1, min. 300V, min. 100°C 2 (Only used in A/B/ TA TUN H05RR-F, min. 0.75 mm DIN EN 50525- VDE inside of final C ELECTRIC H05RN-F (min. 18AWG), 2-21 system) WIRE & 3C, VW-1, min. CABLE CO 300V, min. LTD 100°C 2 A/B/ TA TUN H05RR-F, min. 1.0 mm DIN EN 50525- VDE C ELECTRIC H05RN-F, (min. 17AWG), 2-21 WIRE & H07RN-F 3C, VW-1, min. CABLE CO 300V, min. LTD 100°C 2 (Only used in A/B/ Standard H05RR-F, min. 0.75 mm DIN EN 50525- VDE inside of final C ELECTRIC H05RN-F (min. 18AWG), 2-21 system) WIRE & 3C, VW-1, min. CABLE CO 300V, min. LTD 100°C 2 A/B/ Standard H05RR-F, min. 1.0 mm DIN EN 50525- VDE C ELECTRIC H05RN-F, (min. 17AWG), 2-21 WIRE & H07RN-F 3C, VW-1, min. CABLE CO 300V, min. LTD 100°C 2 (Only used in A/B/ Shanghai H05RR-F, min. 0.75 mm DIN EN 50525- VDE inside of final C Chuangqi H05RN-F (min. 18AWG), 2-21 system) Cable Co., Ltd. 3C, VW-1, min. 300V, min. 100°C TRF No. IEC61347_2_13D Page 18 of 26 Report No.: 11038964 002 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict 2 A/B/ Shanghai H05RR-F, min. 1.0 mm DIN EN 50525- VDE C Chuangqi H05RN-F, (min. 17AWG), 2-21 Cable Co., Ltd. H07RN-F 3C, VW-1, min. 300V, min. 100°C 2 (Only used in A/B/ Zhenjiang H05RR-F, min. 0.75 mm DIN EN 50525- VDE inside of final C Zhongjia H05RN-F (min. 18AWG), 2-21 system) Electric Co., 3C, VW-1, min. Ltd. 300V, min. 100°C 2 A/B/ Zhenjiang H05RR-F, min. 1.0 mm DIN EN 50525- VDE C Zhongjia H05RN-F, (min. 17AWG), 2-21 Electric Co., H07RN-F 3C, VW-1, min. Ltd. 300V, min. 100°C 2 (Only used in A/B/ AWIN WIRE H03VV-F, min. 0.75 mm DIN EN 50525- VDE inside of final C & CABLE CO., H05VV-F (min. 18AWG), 2-11 system) LTD 3C, VW-1, min. 300V, min. 100°C 2 (For indoor A/B/ AWIN WIRE H05VV-F min. 1.0 mm DIN EN 50525- VDE used only) C & CABLE CO., (min. 17AWG), 2-11 LTD 3C, VW-1, min. 300V, min. 100°C 2 (Only used in A/B/ CHUNG H03VV-F, min. 0.75 mm DIN EN 50525- VDE inside of final C KWANG H05VV-F (min. 18AWG), 2-11 system) ELECTRIC 3C, VW-1, min. WIRE & 300V, min. CABLE CO 100°C LTD 2 (For indoor A/B/ CHUNG H05VV-F min. 1.0 mm DIN EN 50525- VDE used only) C KWANG (min. 17AWG), 2-11 ELECTRIC 3C, VW-1, min. WIRE & 300V, min. CABLE CO 100°C LTD 2 (Only used in A/B/ Well Shin H03VV-F, min. 0.75 mm DIN EN 50525- VDE inside of final C Technology H05VV-F (min. 18AWG), 2-11 system) Co., Ltd. 3C, VW-1, min. 300V, min. 100°C 2 (For indoor A/B/ Well Shin H05VV-F min. 1.0 mm DIN EN 50525- VDE used only) C Technology (min. 17AWG), 2-11 Co., Ltd. 3C, VW-1, min. 300V, min. 100°C TRF No. IEC61347_2_13D Page 19 of 26 Report No.: 11038964 002 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict 2 (Only used in A/B/ I-Sheng H03VV-F, min. 0.75 mm DIN EN 50525- VDE inside of final C ELECTRIC H05VV-F (min. 18AWG), 2-11 system) WIRE & 3C, VW-1, min. CABLE CO 300V, min. LTD 100°C 2 (For indoor A/B/ I-Sheng H05VV-F min. 1.0 mm DIN EN 50525- VDE used only) C ELECTRIC (min. 17AWG), 2-11 WIRE & 3C, VW-1, min. CABLE CO 300V, min. LTD 100°C 2 (Only used in A/B/ Unirise Electric H03VV-F, min. 0.75 mm DIN EN 50525- VDE inside of final C Wire & Cable H05VV-F (min. 18AWG), 2-11 system) Co., Ltd. 3C, VW-1, min. 300V, min. 100°C 2 (For indoor A/B/ Unirise Electric H05VV-F min. 1.0 mm DIN EN 50525- VDE used only) C Wire & Cable (min. 17AWG), 2-11 Co., Ltd. 3C, VW-1, min. 300V, min. 100°C 2 (Only used in A/B/ MAINLAD H03VV-F, min. 0.75 mm DIN EN 50525- VDE inside of final C ELECTRIC H05VV-F (min. 18AWG), 2-11 system) WIRE & 3C, VW-1, min. CABLE CO., 300V, min. LTD 100°C 2 (For indoor A/B/ MAINLAD H05VV-F min. 1.0 mm DIN EN 50525- VDE used only) C ELECTRIC (min. 17AWG), 2-11 WIRE & 3C, VW-1, min. CABLE CO., 300V, min. LTD 100°C 2 Output Lead A/B/ Guangzhou TY 1990 min. 1.5 mm DIN VDE 0250 VDE Wire (Single C Tang Yao (min. 14AWG), core 2C, 300/500V, conductor) FEP double (internal wire insulation, only used in 180°C inside of final system) (For HLG-240x-yz, x=H or blank; y=12, 15, 20, 24, 30, 36, 42, 48 or 54; z=A, B, AB or blank) (One provided) TRF No. IEC61347_2_13D Page 20 of 26 Report No.: 11038964 002 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict 2 Output cable A/B/ Lucky United H05RR-F, min. 1.5 mm DIN EN 50525- VDE (For HLG- C H07RN-F (min. 14AWG), 2-21 240x-yz, x=H 2C, VW-1, min. or blank; y=12, 300V, min. 15, 20, 24, 30, 100°C 36, 42, 48 or 54; z=A, B, AB or blank) (One provided) 2 A/B/ Lucky United H05BB-F min. 1.5 mm DIN EN 50525- VDE C (min. 14AWG), 2-21 2C, VW-1, min. 300V, min. 100°C 2 A/B/ Guangdong H05RR-F, min. 1.5 mm DIN EN 50525- VDE C Rifeng H07RN-F (min. 14AWG), 2-21 2C, VW-1, min. 300V, min. 100°C 2 A/B/ Dong Guan H05RR-F, min. 1.5 mm DIN EN 50525- VDE C Recheer H07RN-F (min. 14AWG), 2-21 2C, VW-1, min. 300V, min. 100°C 2 A/B/ Zheng Yu H05RR-F, min. 1.5 mm DIN EN 50525- VDE C H07RN-F (min. 14AWG), 2-21 2C, VW-1, min. 300V, min. 100°C 2 A/B/ TA TUN H05RR-F, min. 1.5 mm DIN EN 50525- VDE C ELECTRIC H07RN-F (min. 14AWG), 2-21 WIRE & 2C, VW-1, min. CABLE CO 300V, min. LTD 100°C 2 A/B/ Standard H05RR-F, min. 1.5 mm DIN EN 50525- VDE C ELECTRIC H07RN-F (min. 14AWG), 2-21 WIRE & 2C, VW-1, min. CABLE CO 300V, min. LTD 100°C 2 A/B/ Shanghai H05RR-F, min. 1.5 mm DIN EN 50525- VDE C Chuangqi H07RN-F (min. 14AWG), 2-21 Cable Co., Ltd. 2C, VW-1, min. 300V, min. 100°C 2 A/B/ Zhenjiang H05RR-F, min. 1.5 mm DIN EN 50525- VDE C Zhongjia H07RN-F (min. 14AWG), 2-21 Electric Co., 2C, VW-1, min. Ltd. 300V, min. 100°C TRF No. IEC61347_2_13D Page 21 of 26 Report No.: 11038964 002 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict 2 (For indoor A/B/ AWIN WIRE H05VV-F, min. 1.5 mm DIN EN 50525- VDE used and used C & CABLE CO., H05VVH2-F (min. 14AWG), 2-11 in inside of LTD 2C, VW-1, min. final system 300V, min. only) 100°C 2 (For indoor A/B/ CHUNG H05VV-F min. 1.5 mm DIN EN 50525- VDE used and used C KWANG (min. 14AWG), 2-11 in inside of ELECTRIC 2C, VW-1, min. final system WIRE & 300V, min. only) CABLE CO 100°C LTD 2 (For indoor A/B/ Well Shin H05VV-F min. 1.5 mm DIN EN 50525- VDE used and used C Technology (min. 14AWG), 2-11 in inside of Co., Ltd. 2C, VW-1, min. final system 300V, min. only) 100°C 2 (For indoor A/B/ I-Sheng H05VV-F min. 1.5 mm DIN EN 50525- VDE used and used C ELECTRIC (min. 14AWG), 2-11 in inside of WIRE & 2C, VW-1, min. final system CABLE CO 300V, min. only) LTD 100°C 2 (For indoor A/B/ Unirise Electric H05VV-F min. 1.5 mm DIN EN 50525- VDE used and used C Wire & Cable (min. 14AWG), 2-11 in inside of Co., Ltd. 2C, VW-1, min. final system 300V, min. only) 100°C 2 (For indoor A/B/ MAINLAD H05VV-F min. 1.5 mm DIN EN 50525- VDE used and used C ELECTRIC (min. 14AWG), 2-11 in inside of WIRE & 2C, VW-1, min. final system CABLE CO., 300V, min. only) LTD 100°C 2 Dimming lead A/B/ Guangzhou TY 1990 min. 0.75 mm DIN VDE 0250 VDE wire C Tang Yao (min. 18AWG), (Single core 2C, 300/500V, conductor) FEP double (internal wire insulation, only used in 180°C inside of final system) (Used for HLG-240x- yB and HLG- 240H-yAB) 2 (Only used in A/B/ Lucky United H05RR-F, min. 0.75 mm DIN EN 50525- VDE inside of final C H05RN-F (min. 18AWG), 2-21 system) 2C, VW-1, min. 300V, min. 100°C TRF No. IEC61347_2_13D Page 22 of 26 Report No.: 11038964 002 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict 2 A/B/ Lucky United H05RR-F, min. 1.0 mm DIN EN 50525- VDE C H05RN-F, (min. 17AWG), 2-21 H07RN-F 2C, VW-1, min. 300V, min. 100°C 2 (Only used in A/B/ Lucky United H05BB-F, min. 0.75 mm DIN EN 50525- VDE inside of final C H05BN4-F (min. 18AWG), 2-21 system) 2C, VW-1, min. 300V, min. 100°C 2 A/B/ Lucky United H05BB-F, min. 1.0 mm DIN EN 50525- VDE C H05BN4-F (min. 17AWG), 2-21 2C, VW-1, min. 300V, min. 100°C 2 (Only used in A/B/ Guangdong H05RR-F, min. 0.75 mm DIN EN 50525- VDE inside of final C Rifeng H05RN-F (min. 18AWG), 2-21 system) 2C, VW-1, min. 300V, min. 100°C 2 A/B/ Guangdong H05RR-F, min. 1.0 mm DIN EN 50525- VDE C Rifeng H05RN-F (min. 17AWG), 2-21 H07RN-F 2C, VW-1, min. 300V, min. 100°C 2 (Only used in A/B/ Dong Guan H05RR-F, min. 0.75 mm DIN EN 50525- VDE inside of final C Recheer H05RN-F (min. 18AWG), 2-21 system) 2C, VW-1, min. 300V, min. 100°C 2 A/B/ Dong Guan H05RR-F, min. 1.0 mm DIN EN 50525- VDE C Recheer H05RN-F (min. 17AWG), 2-21 H07RN-F 2C, VW-1, min. 300V, min. 100°C 2 (Only used in A/B/ Zheng Yu H05RR-F, min. 0.75 mm DIN EN 50525- VDE inside of final C H05RN-F (min. 18AWG), 2-21 system) 2C, VW-1, min. 300V, min. 100°C 2 A/B/ Zheng Yu H05RR-F, min. 1.0 mm DIN EN 50525- VDE C H05RN-F, (min. 17AWG), 2-21 H07RN-F 2C, VW-1, min. 300V, min. 100°C TRF No. IEC61347_2_13D Page 23 of 26 Report No.: 11038964 002 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict 2 (Only used in A/B/ TA TUN H05RR-F, min. 0.75 mm DIN EN 50525- VDE inside of final C ELECTRIC H05RN-F (min. 18AWG), 2-21 system) WIRE & 2C, VW-1, min. CABLE CO 300V, min. LTD 100°C 2 A/B/ TA TUN H05RR-F, min. 1.0 mm DIN EN 50525- VDE C ELECTRIC H05RN-F, (min. 17AWG), 2-21 WIRE & H07RN-F 2C, VW-1, min. CABLE CO 300V, min. LTD 100°C 2 (Only used in A/B/ Standard H05RR-F, min. 0.75 mm DIN EN 50525- VDE inside of final C ELECTRIC H05RN-F (min. 18AWG), 2-21 system) WIRE & 2C, VW-1, min. CABLE CO 300V, min. LTD 100°C 2 A/B/ Standard H05RR-F, min. 1.0 mm DIN EN 50525- VDE C ELECTRIC H05RN-F, (min. 17AWG), 2-21 WIRE & H07RN-F 2C, VW-1, min. CABLE CO 300V, min. LTD 100°C 2 (Only used in A/B/ Shanghai H05RR-F, min. 0.75 mm DIN EN 50525- VDE inside of final C Chuangqi H05RN-F (min. 18AWG), 2-21 system) Cable Co., Ltd. 2C, VW-1, min. 300V, min. 100°C 2 A/B/ Shanghai H05RR-F, min. 1.0 mm DIN EN 50525- VDE C Chuangqi H05RN-F (min. 17AWG), 2-21 Cable Co., Ltd. H07RN-F 2C, VW-1, min. 300V, min. 100°C 2 A/B/ Zhenjiang H05RR-F, min. 0.75 mm DIN EN 50525- VDE C Zhongjia H05RN-F (min. 18AWG), 2-21 Electric Co., 2C, VW-1, min. Ltd. 300V, min. 100°C 2 A/B/ Zhenjiang H05RR-F, min. 1.0 mm DIN EN 50525- VDE C Zhongjia H05RN-F (min. 17AWG), 2-21 Electric Co., H07RN-F 2C, VW-1, min. Ltd. 300V, min. 100°C 2 (Only used in A/B/ AWIN WIRE H03VV-F, min. 0.75 mm DIN EN 50525- VDE inside of final C & CABLE CO., H03VVH2-F, (min. 18AWG), 2-11 system) LTD H05VV-F, 2C, VW-1, min. H05VVH2-F 300V, min. 100°C TRF No. IEC61347_2_13D Page 24 of 26 Report No.: 11038964 002 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict 2 (For indoor A/B/ AWIN WIRE H05VV-F, min. 1.0 mm DIN EN 50525- VDE used and used C & CABLE CO., H05VVH2-F (min. 17AWG), 2-11 in inside of LTD 2C, VW-1, min. final system 300V, min. only) 100°C 2 (Only used in A/B/ CHUNG H03VV-F, min. 0.75 mm DIN EN 50525- VDE inside of final C KWANG H03VVH2-F, (min. 18AWG), 2-11 system) ELECTRIC H05VV-F, 2C, VW-1, min. WIRE & H05VVH2-F 300V, min. CABLE CO 100°C LTD 2 (For indoor A/B/ CHUNG H05VV-F, min. 1.0 mm DIN EN 50525- VDE used and used C KWANG H05VVH2-F (min. 17AWG), 2-11 in inside of ELECTRIC 2C, VW-1, min. final system WIRE & 300V, min. only) CABLE CO 100°C LTD 2 (Only used in A/B/ Well Shin H03VV-F, min. 0.75 mm DIN EN 50525- VDE inside of final C Technology H03VVH2-F, (min. 18AWG), 2-11 system) Co., Ltd. H05VV-F, 2C, VW-1, min. H05VVH2-F 300V, min. 100°C 2 (For indoor A/B/ Well Shin H05VV-F, min. 1.0 mm DIN EN 50525- VDE used and used C Technology H05VVH2-F (min. 17AWG), 2-11 in inside of Co., Ltd. 2C, VW-1, min. final system 300V, min. only) 100°C 2 (Only used in A/B/ I-Sheng H03VV-F, min. 0.75 mm DIN EN 50525- VDE inside of final C ELECTRIC H03VVH2-F, (min. 18AWG), 2-11 system) WIRE & H05VV-F, 2C, VW-1, min. CABLE CO H05VVH2-F 300V, min. LTD 100°C 2 (For indoor A/B/ I-Sheng H05VV-F, min. 1.0 mm DIN EN 50525- VDE used and used C ELECTRIC H05VVH2-F (min. 17AWG), 2-11 in inside of WIRE & 2C, VW-1, min. final system CABLE CO 300V, min. only) LTD 100°C 2 (Only used in A/B/ Unirise Electric H03VV-F, min. 0.75 mm DIN EN 50525- VDE inside of final C Wire & Cable H03VVH2-F, (min. 18AWG), 2-11 system) Co., Ltd. H05VV-F, 2C, VW-1, min. H05VVH2-F 300V, min. 100°C 2 (For indoor A/B/ Unirise Electric H05VV-F, min. 1.0 mm DIN EN 50525- VDE used and used C Wire & Cable H05VVH2-F (min. 17AWG), 2-11 in inside of Co., Ltd. 2C, VW-1, min. final system 300V, min. only) 100°C TRF No. IEC61347_2_13D Page 25 of 26 Report No.: 11038964 002 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict 2 (Only used in A/B/ MAINLAD H03VV-F, min. 0.75 mm DIN EN 50525- VDE inside of final C ELECTRIC H03VVH2-F, (min. 18AWG), 2-11 system) WIRE & H05VV-F, 2C, VW-1, min. CABLE CO., H05VVH2-F 300V, min. LTD 100°C 2 (For indoor A/B/ MAINLAD H05VV-F min. 1.0 mm DIN EN 50525- VDE used and used C ELECTRIC (min. 17AWG), 2-11 in inside of WIRE & 2C, VW-1, min. final system CABLE CO., 300V, min. only) LTD 100°C Functional Components 2 Input Lead A/B/ Interchangeabl Interchangeable min. 0.75 mm UL 62, UL758 UL Wire/cable C e (min. 18AWG), (Flexible 3C, VW-1, min. conductors) 300V, min. (Only used in 100°C inside of final system) 2 Input Lead A/B/ Interchangeabl Interchangeable min. 1.0mm UL 62, UL758 UL Wire/cable C e (min. 17AWG), (Flexible 3C, VW-1, min. conductors) 300V, min. (Only used in 100°C inside of final system) 2 Output Lead A/B/ Interchangeabl Interchangeable min. 1.5 mm UL 758, UL 62 UL Wire C e (min. 14AWG), (For HLG- 2C, VW-1, min. 240x-yz, x=H 300V, min. or blank; y=12, 100°C 15, 20, 24, 30, 36, 42, 48 or 54; z=A, B, AB or blank) (One provided) (Only used in inside of final system) 2 Dimming lead A/B/ Interchangeabl Interchangeable min. 0.75 mm UL 758, UL 62 UL wire (used for C e (min. 18AWG), HLG-240x-yB 2C, VW-1, min. and HLG- 100°C, min 240H-yAB) 300V (Only used in inside of final system) TRF No. IEC61347_2_13D Page 26 of 26 Report No.: 11038964 002 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict 2 Dimming lead A/B/ Interchangeabl Interchangeable min. 1.0 mm UL 758, UL 62 UL wire (used for C e (min. 17AWG), HLG-240x-yB 2C, VW-1, min. and HLG- 100°C, min 240H-yAB) 300V (Only used in inside of final system) The codes above have the following meaning: A - The component is replaceable with another one, also certified, with equivalent characteristics B - The component is replaceable if authorised by the test house C - Integrated component tested together with the appliance D - Alternative component TRF No. IEC61347_2_13D
Enter the password to open this PDF file:
-
-
-
-
-
-
-
-
-
-
-
-