VRV IV+ Sets the Standard... Again VRV IV+ heat pump and water cooled systems High Ambient Why choose Daikin Our promise is to ensure that your customers can depend on Daikin for the ultimate in comfort, so that they are free to focus on their own working and home lives. We promise to dedicate ourselves to technological excellence, a design focus and the highest quality standards so that your customers can trust and rely on the comfort we deliver. Our promise to the planet is absolute. Our products are at the forefront of low energy consumption and we continuously innovate to reduce the environmental impact of HVACR solutions further. We lead where others follow. We will continue our global leadership in HVACR solutions as our specialist expertise in all market sectors combined with 90 years’ experience enable us to deliver added value in long-lasting relationships based on trust, respect and credibility. 1 Table of contents VRV History 3 VRV IV+ Standards & Technologies 5 Variable Refrigerant Temperature 6 VRV Configurator Software 8 Unique VRV IV+ Technologies 9 VRV Benefits 11 Product Overview 13 Outdoor Units 15 Indoor Units 19 Ventilation and Air Handling Control 33 Control Systems 35 Supporting Tools 57 2 Over 30 years of VRV History 1987 1998 2004 2008 Introduction of the original VRV air Launch of the inverter series Expansion to light commercial sector with Launch of heat pump conditioning system to Europe, with R-407C VRVII-S optimised for heating invented by Daikin in 1982 › - › (VRV II-C) › › › Extended operation › systems 1987 1991 1994 1987 1998 1991 2003 1994 19982004 20032005 2006-2007 2005 2004 2003 Introduction of VRVII-S- the first R-410A VRF system 2005 1991 Available in cooling, heat pump and Extension of VRVII-S inverter range with Introduction of heat recovery VRV heat recovery › water cooled VRV-WIII › Simultaneous cooling and 1994 refrigerant circuit › Available in heat pump and heating Awarded ISO-9001 certification heat recovery 3 2009 2011 2015 Extension of VRV III range Launch of total solution concept Launch of VRV IV S-series with water cooled VRV-WIII › Integration of hot water production and › Most compact unit in the market › Geothermal version available biddle air curtains into VRV system › Widest range in the market › › Connectable to Daikin Emura and Nexura › 400,000 outdoor units sold › 2.2 million indoor units sold 06-2007 2009 2008 2010 2009 2011 2010 2012 2011 2015 2012 2015 2019 2006-2007 Launch of the extensively re-engineered VRV III 2010 2012-2014 2015 2019 › Available in cooling, Launch of replacement VRV Setting new standards with the Launch of VRV IV i-series Launch of VRV IV+ › 7th generation of inverter heat pump and heat (VRV III-Q) launch of VRV IV › The invisible VRV compressor with back recovery › Upgrade to replace older VRV units › 28% improved seasonal efficiency › Unique product concept pressure control › Automatic charging and › Continuous heating on heat VRV IV High Ambient › Improved seasonal testing pumps efficiency (15% on › Up to 64 units to be › Available in heat pump, heat average) connected to 1 system recovery, water-cooled and replacement series 4 VRV IV+ 3 revolutionary standards > Variable Refrigerant Temperature VRV IV+ standards > Refrigerant-cooled PCB > VRV configurator & technologies + unique VRV IV+ Our new VRV IV+ systems set pioneering core technologies standards in all-round climate comfort > Newly-developed inverter compressor with performance. Total design simplicity, back pressure control offering rapid installation, full flexibility > 4-side heat exchanger > Improved SEER and EER as well as absolute efficiency and > Predictive control comfort. Find out about all these > Outer rotor DC fan motor revolutionary changes at www.daikinmea.com 5 Variable refrigerant temperature Customise your VRV for best seasonal efficiency and comfort The colder it gets the lower the cooling need of the Cooling requirement in cooling mode Capacity & Load building Design point Thanks to its revolutionary variable refrigerant Adjust capacity by temperature technology (VRT), VRV IV+ continuously Te control to meet the load (avoid over adjusts both the inverter compressor speed and the capacity System capacity and ON/OFF operation) refrigerant temperature, providing the necessary capacity to meet the building load with the highest seasonal efficiency at all times! The lower the capacity need, the higher the refrigerant Refrigerant temperature temperature can be › Seasonal efficiency increased by 28% (compared to conventional VRF) › Fistt weather compensating control on the Variable Te market › Customer comfort is assured thanks to higher outblow temperatures (preventing cold Fixed Te draughts) The higher the refrigerant the higher the efficiency How does it work? Seasonal efficiency temperature, Efficiency up Efficiency with Variable Refrigerant Temperature VRF standard Capacity is controlled only with the variance of the inverter compressor Daikin VRV IV+ 20° 25° 30° 35° Outdoor temperature Variable Refrigerant Temperature control for energy saving in partial load condition. The capacity is controlled by the inverter compressor AND variation of the evaporating (Te) and condens- ing (Tc) temperature of the refrigerant in order to achieve the highest seasonal efficiency. 6 8 Different modes to Check on maximise efficiency and comfort https://www.youtube.com/ DaikinEurope For maximum energy efficiency and customer satisfaction, the outdoor unit needs to adapt the evaporating/condensing temperature at the optimum point for the application. How to set the different modes? pa 6 Set up the main operation mode Define how the system reacts te nt s of the system to changing loads Step 1 Step 2 Automatic* Where a quick increase of load is expected such as conference rooms. Evaporating AND condensing temperature automatically Powerful Quick reaction speed to changing load has priority, with temporarily colder selected according to ambient temperature outblow as a result. Quick reaction speed Top efficiency Quick Same as above but slower response than the powerful mode. This mode would be suitable for most office applications The perfect balance: Achieves top efficiency throughout the year, Mild * and it is the factory set mode. reacts quickly on the hottest days The perfect balance: Slower reaction speed with top efficiency High sensible Gives customer choice for fixing coil temperature which avoids cold draughts. Target Te can be selected between 7°Cto 11°C Powerful A quick reaction speed to changing load has priority, with temporarily colder outblow as a result. Quick Same as above but slower response. Quick reaction speed Top efficiency The air off temperature remains fairly constant. Mild Suitable for low ceiling rooms. Year round top efficiency Coil temperature would not change due to fluctuating load. Eco Suitable for computer or low ceiling rooms. Basic No submodes This is how most other VRF systems work and can be used Current VRF standard for all general type of applications. * Factory setting 7 VRV configurator software Software for simplified commissioning, configuration and customisation Check on › Graphical interface › Manage systems over multiple sites in exactly https://www.youtube.com/ the same way DaikinEurope › Retrieve initial settings Configurator software for simplified commissioning The VRV configurator is an advanced software solution that allows for easy system configuration Simplified and commissioning: commissioning › less time is required on the roof configuring the outdoor unit › multiple systems at different sites can be managed Retrieve initial system in exactly the same way, thus offering simplified settings commissioning for key accounts User friendly interface instead of › initial settings on the outdoor unit can be easily push buttons retrieved. 7-segment display for quick and accurate error diagnosis Outdoor unit display for quick on-site settings and easy read out of errors together with the indication of service parameters for checking basic functions. › Easy-to-read error report › Clear menu indicating quick and easy on-site settings › Indication of basic service parameters to quickly check basic functions: high pressure, low pressure, frequency and operation time history of compressors, temperature of discharge/suction pipe. 3 digit 7-segment display › No need to unmount the big front panel of the unit thanks to the service access 8 Unique VRV IV+ core technologies 37 NEW Scroll compressor Check on patents https://www.youtube.com/ Back pressure control UNIQUE DaikinEurope › Pressure port increases pressure below the scroll in low load operation, preventing refrigerant leak from the high to low pressure side › Increased partial load efficiency The back pressure control port sends high pressure refrigerant Refrigerant leak at low load with conventional compressor to the back of the scroll, preventing refrigerant leakage Refrigerant-cooled PCB › Reliable cooling because it is not influenced by ambient air temperature › Smaller switchbox for smoother air flow through the heat exchanger increasing heat exchange efficiency by 5% patents 4-sided, 3-row condenser coil › Condenser coil surface up t rger › (up t ), leading t re efficiency patents 9 UNIQUE Waste compressor operation Target Predictive Control Function (PCF) General VRF: Double time against VRV IV t › Reaches the target capacity/refrigerant temperature (VRV IV+) t (general VRF) faster VRV IV+ with PCF › Reaches the target without overshooting, so there is General VRF with PI control no waste, leading to improved efficiency Target capacity/refrigerant temperature › Three capacity settings give more precise control VRV IV: PCF for user comfort Compressor works with predictive data for the control The large number of Daikin systems already in operation › result: quick convergence to the target temperature Half time and which are monitored by our Intelligent Network and reduction of waste operation of the compressor against software put us in the unique position of being able to general analyse this data and develop the predictive compressor General VRF: Pi control VRF Compressor works with feedback only for the control control function. › result: waste operation and longer time before reaching target set point DC fan motor UNIQUE Outer rotor DC motor for higher e ciency Conventional motor with inner rotor Daikin outer rotor › Larger rotor diameter results in greater force for the same magnetic field, leading to better efficiency › Better control, resulting in more fan steps to match the actual capacity Sine wave DC inverter F Optimizing the sine wave curve results in smoother F motor rotation and improved motor efficiency. Rotor Stator Stator Rotor DC fan motor The use of a DC fan motor offers substantial improvements in operating efficiency compared to conventional AC motors, especially during low speed rotation. Standard heat exchanger e-Pass heat exchanger E-Pass Heat Exchanger Optimising the heat exchanger’s path layout prevents In °C In °C heat being transferred from the overheated gas °C °C section to the sub-cooled liquid section which is a more efficient way to use the heat exchanger. °C °C °C °C °C °C °C °C I-demand function Power consumption Pre-defined limit Limit maximum power consumption. The newly introduced current sensor minimizes the difference between the actual power consumption and the pre-defined power consumption. Time 10 ECPEN15-206A.indd 4 24/03/15 11:47 Benefits of a VRV IV+ installation Consultants Outdoor units can be single units or combined in multiple units as a module for larger capacity applications Daikin's VRV IV+ technology maximises flexibility and leads the way in customisation to match individual building requirements in comfort and energy, with reduced running costs. Technical design support Ecological design meets and exceeds legal requirements Maximum flexibility to meet customer requirements Advanced software tools assist with system design Complies with ESMA UAE, MEW-Kuwait, SASO-KSA, and QCC Abu Dhabi regulations Building owners VRV IV+ VRV IV+ is the ultimate in customised comfort and intelligent control tailored to your individual needs and to maximise energy efficiency. Annual cost savings up to % (compared to conventional VRF). Up to 40% energy consumption saving over conventional AC system Single point of contact for the design and maintenance of your climate system Integrated system, combining air conditioning, ventilation, etc. Allows maximum energy efficiency Multiple systems can be managed in exactly the same way for the key accounts Dedicated after-sales service to ensure fast on-site support Installers Water cooled VRV Daikin VRV IV+ sets the standard with state-of-the- art technology and time-saving commissioning and servicing. Simplified and time-saving commissioning with VRV configurator Wide range of outdoor units (up to 48HP) One supplier = one point of contact Maximum flexibility to meet customer requirements Customised training to maximise expertise VRV IV S-series 11 Anti-Corrosion Treatment An anti-corrosion heat exchanger cutaway view Hydrophilic film Special anti-corrosion treatment of the heat exchanger Aluminium provides 5 to 6 times greater resistance against acid Corrosion-resistant rain and salt corrosion. Acrylic resin Heat exchanger The provision of rust proof steel sheet on the underside of the unit gives additional protection. Degree of corrosion Performed tests: 8 7 › VDA Wechseltest 6 5 › 4 3 › 2 1 › 0 Bare aluminium 1 2 3 4 5 Cycle DAIKIN P.E. › Degree of corrosion 10 Kesternich test (SO2) 9 8 › 7 6 5 › 4 3 2 1 0 1 2 3 4 5 6 10 20 30 40 50 60 70 Cycle The total solution One system - multiple applications for hotels, offices, retail shops and home. Typically, many buildings today rely on several separate systems for heating, cooling & air curtain As a result energy is wasted. To provide a much more efficient alternative, VRV technology has been developed into a total solution managing up to 70% of a building's energy consumption, giving large potential to cost saving. 22 › Heating and cooling for year round comfort › Controls for maximum operating efficiency Heating Cooling Controls Ventilation › Ventilation Fresh Air for high quality environments 12 ECPEN15-206A.indd 8 24/03/15 11:48 Outdoor units RXYTQ-U NEW + + › › Covers all thermal needs of a building via a single point of contact: accurate VRV IV-S RXYSQ-T series temperature control, ventilation, air handling units › Connect VRV indoor units › Incorporates VRV IV standards & technologies such as Variable Refrigerant temperature RWEYQ-T + - Connect wide range of VRV indoor units 2 analogue input signals allowing external control 6 RXYTQ-U (50/60Hz) RXYSQ-T (50Hz-8/10/12HP 50/60Hz-6HP) RWEYQ-T + (50Hz) 13 ECPEN15-206A.indd 9 24/03/15 11:48 NEW Black and designer NEW panels Widest choice ever in decoration panel designs and colours with new black panel FXFQ-BVEB FXZQ-A2VEB Thin, lightweight design installs easily in narrow ceiling spaces › ceiling › Flexibility to suit every room layout mounted › Reduced energy consumption thanks to DC fan motor cassette › › FXCQ-AVEB Multi zoning option FXDQ-A3VEB Multi zoning option FXSQ-A2VEB FXMQ-P7VEB9 FXMQ140PVE FXMQ-MAVE FXHQ-AVEB FXUQ-AVEB FXLQ-P2VEB FXNQ-A2VEB 14 Outdoor Units RXYTQ-U7YF VRV IV+ heat pump Model RXYTQ8U7YF RXYTQ10U7YF RXYTQ12U7YF RXYTQ14U7YF RXYTQ16U7YF (1) Cooling T1 35°C Capacity Ton 6.4 8.0 9.5 11.4 12.8 (Nominal) Capacity kW 22.4 28.0 33.5 40.0 45.0 Capacity Btu/h 76,432 95,540 114,307 136,486 153,546 EER (Btu/h) / W 13.3 13.3 12.0 11.2 11.2 PI kW 5.75 7.18 9.52 12.14 13.72 Cooling T3(2) 46°C Capacity Btu/h 68,925 85,986 97,246 109,189 119,766 Capacity kW 20.2 25.2 28.5 32.0 35.1 EER Btu/h 10.2 10.1 9.9 9.6 9.4 PI kW 6.75 8.51 9.8 11.33 12.79 PI out kW 6.57 8.29 8.64 10.17 11.63 (3) Heating (nominal) Capacity kW 22.4 28.0 33.5 40.0 45.0 Capacity Btu/h 76432 95540 114307 136486 153546 COP kW/kW 3.99 3.89 3.64 3.63 3.48 PI kW 5.62 7.2 9.19 11.01 12.92 Sound level (nominal) Sound pressure dBA 57 59 61 61 64 Dimensions HxWxD mm 1685x930x765 1685 x 1240 x 765 VRV IV+ Net Weight kg 198 234 234 283 283 Operation range cooling Outdoor -5〜55°CDB Indoor 14〜25°CWB Operation range heating Outdoor -20〜15.5°CWB Indoor 15〜27°CDB Refrigerant Type R-410A Pipe connection Liquid Ø 9.52 mm Ø 9.52 mm Ø 12.7 mm Gas Ø 19.1 mm Ø 22.2 mm Ø 28.6 mm Total Piping Length System Actual m 1000 Max connectable indoor units 64 Wiring length Total Wiring Length: 2000m Compressors 1 1 1 2 2 Power supply 3 Phase/ 380-415V/50Hz 3 Phase/ 400V/60Hz EER Comparison at T3, (Btu/h)/W EER Comparison at T1, (Btu/h)/W 13.3 13.3 12 13.5 10.2 10.1 9.9 9.6 9.4 13.0 10 8.3 8.3 7.8 7.8 7.8 12.5 8 12.0 12.0 6 11.5 11.2 11.2 11.2 11.2 11.2 11.2 11.2 4 11.0 2 10.5 0 10.0 8 HP 10 HP 12 HP 14 HP 16 HP 8 HP 10 HP 12 HP 14 HP 16 HP ESMA DAIKIN AD QCC DAIKIN (1) indoor temperature: 26,7°CD B, 19,4°CWB, outdoor temperature: 35°CDB, AHRI 1230:2010, power input indoor units (duct type) included. (As per AHRI) (2) indoor temperature: 29,0°CDB, 19,0°CWB, outdoor temperature: 46°CDB, ISO15042:2011, power input indoor units (duct type) included. (As per ESMA) (3) Heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. 15 Great design flexibility Flexible piping design Total piping length 1000m Longest length actual (Equivalent) 165m (190m) Longest length aft anch 90m1 Lev erence between indoor and outdoor units 90m1 Lev erence between indoor units 30m *Refer to technical data book for more information and restrictions. Free combination of outdoor units 40m (90m1) Level difference between indoor and 30m Level difference between indoor units Outdoor units can be used as single units or multiple units combined as a 165m Actual piping length module for larger capacity applications. This allows for maximum optimization outdoor units for smaller footprints or highest efficiency. 90m maximum Indoor installation The VRV optimised fan blade shape increases output and reduces pressure loss. Together with the high ESP setting (up to 78.4 Pa), it makes VRV outdoor units ideal for indoor installation using ducts. Recommended cable size Model RXYTQ8U7YF RXYTQ10U7YF RXYTQ12U7YF RXYTQ14U7YF RXYTQ16U7YF Power cable Sq mm 4 4 4 6 6 Control cable size 0.75 to 1.25 sq.mm PVC sheathed, non-shielded, 2-core Circuit breaker size A 20.0 25.0 32.0 32.0 40.0 Note: These are the minimum required values. Refer to local regulations for further information. 16 RXYSQ-TMY VRV IV S-series heat pump Space saving solution without compromising on ciency Space saving trunk design for ible installation Covers all thermal needs of a building via a single point of contact: accurate temperature control, ventilation, air handling units. Wide range of indoor units: Incorporates VRV IV standards & technologies: Variable Refrigerant Temperature and full inverter compressors for example during periods with high power demand Contains all standard VRV features RXYSQ-TMY VRV IV-S heat pump Model RXYSQ- 6TMYFK 8TMY1B 10TMY1B 12TMY1B Capacity HP 6 8 10 12 Capacity kW 15.3 22.4 28 33.5 Cooling T1(1) 35ºC Nominal Capacity Btu/h 52,000 76,400 95,500 114,300 EER (Btu/h) / W 11.42 11.3 11.2 11.2 PI kW 4.55 6.78 8.54 10.2 Capacity kW 12.89 17 20 24 Capacity Btu/h 44,000 58,000 68,200 81,850 Cooling T3(2) 46ºC EER (Btu/h) / W 8.36 10 9.72 9.52 PI kW 5.26 5.8 7.02 8.6 Capacity kW 12.3 22.4 28.0 33.5 Capacity Btu/h 42,000 76,400 95,500 114,300 Heating (nominal)(3) COP kW/kW 4.31 4.31 4.24 4.09 PI kW 2.87 5.2 6.6 8.19 Sound Level (nominal) Sound Pressure dBA 51 55 55 57 Dimensions HxWxD 1615 x 940 x 460 1,430 x 940 x 320 1,615 x 940 x 460 Weight Unit Kg 175 144 178 180 Operation Range Outdoor -5~55CDB Cooling Indoor 14~25 CWB Operation Range Outdoor -20~15.5CWB Heating Indoor 15~27 CDB Refrigerant Type R-410A Liquid 9.52 9.52 9.52 12.7 Pipe Connections Gas 22.2 22.2 22.2 25.4 Total Piping Length System Actual m 300 Max. Connectable Indoor Units 12 21 26 26 380-415V/50Hz Power Supply 400V/60Hz 3 Phase 380-415V / 50 Hz (1) Indoor temperature: 26.7 ºCDB, 19.4 ºCWB, Outdoor temperature: 35 ºCDB, AHRI 1230:2010, power input indoor units (duct type) included. As per AHRI/SASO (2) Indoor temperature: 29 ºCDB, 19 ºCWB, outdoor temperature: 46°CDB, (3) Heating capacities are based on indoor temperature: 20 ºCDB, outdoor ISO15042:2011, power input indoor units (duct type) included. As per ESMA. temperature: 7 ºCDB, 6 ºCWB, equivalent 17 RWEYQ-T9 VRV IV water cooled series - 50Hz Ideal for high rise buildings, using water as heat source Geothermal series reduce CO emmisions thanks to the use of geothermal energy as a renewable energy source No need for an external heating or cooling source when used in geothermal mode Covers all thermal needs of a building via a single point of contact: accurate temperature control, ventilation, air handling units, Biddle air curtains and hot water RWEYQ Wide range of indoor units Compact & lightweight design can be stacked for maximum space saving Stacked configuration Incorporates VRV IV standards & technologies: Variable Refrigerant Temperature and full inverter compressors Water piping Refrigerant piping Ceiling height stage between outdoor units thanks to the storage of energy in the water circuit Available in heat pump and heat recovery version 14HP 3.3m height Contains all standard VRV features 14HP Main Benefits Minimal technical room space required 14HP Indoor installation makes units invisible from the outside Outdoor unit RWEYQ Capacity range HP Cooling capacity Nom. kW Heating capacity Nom. kW Cooling kW Heating kW EER at nom. capacity kW/kW COP at nom. capacity kW/kW Maximum number of connectable indoor units Indoor index Min. connection Nom. Max. Dimensions Unit HeightxWidthxDepth mm Weight Unit kg Sound pressure level Cooling Nom. dBA Operation range Inlet water Cooling Min.~Max. °CDB temperature Heating Min.~Max. °CWB Temperature around casing Max. °CDB Humidity around casing Cooling~Heating % Refrigerant Type/GWP Charge Piping connections Liquid OD mm Gas OD mm HP/LP gas OD mm Drain Size Water Inlet/Outlet Total piping length System Actual m Power supply Phase/Frequency/Voltage Hz/V Maximum fuse amps (MFA) A 18 The most comfortable cassette just got better New round flow cassette ››Bigger flaps and new sensor logic further improves equal air distribution in the room ››Widest ever choice in panels for cassette units, with up to 8 different panels Black auto cleaning panel Black designer panel Full white standard panel White designer panel ››Comes with the known benefits: 360° air flow discharge and intelligent sensors* presence floor sensor sensor ››Auto cleaning panels available in black and white Auto cleaning filter Dust can simply be removed using a vacuum cleaner without opening the unit. * Available as an option 19 FXFQ-BVEB Round flow cassette 360° air discharge for optimum efficiency and comfort › Automatic filter cleaning results in higher efficiency & comfort and lower maintenance costs. 2 filters available: standard filter and finer mesh filter (for fine dust applications e.g. clothing shops) › Two optional intelligent sensors improve energy efficiency and comfort NEW › Widest choice ever in decoration panels: Designer, standard and FXFQ-B autocleaning panels in white (RAL9010) and black (RAL9005) NEW › Bigger flaps improve equal air distribution › Individual flap control: flexibility to suit every room layout without changing the location of the unit! › Lowest installation height in the market: 214mm rfor class 20-63 › Optional fresh air intake › Branch duct discharge allows to optimize air distribution in irregular shaped rooms or to supply air to small adjacent rooms BRC1H 81W BRC7FA532F* Main unit Branch discharge Main discharge ŰŰ Standard drain pump with 675mm lift increases flexibility and installation speed White panel White design panel Black panel Black design panel 675 mm Indoor unit FXFQ 20B 25B 32B 40B 50B 63B 80B 100B 125B Cooling capacity Total capacity Nom. kW 2.20 2.80 3.60 4.50 5.60 7.10 9.00 11.20 14.00 Heating capacity Total capacity Nom. kW 2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0 Power input - 50Hz Cooling Nom. kW 0.04 0.05 0.06 0.09 0.12 0.19 Heating Nom. kW 0.04 0.05 0.06 0.09 0.11 0.18 Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840 288x840x840 Weight Unit kg 19 20 21 24 26 Casing Material Galvanised steel plate Decoration panel Model Standard panels: BYCQ140E - white with grey louvers / BYCQ140EW - full white / BYCQ140EB - black Auto cleaning panels BYCQ140EGF - white / BYCQ140EGFB - black Designer panels: BYCQ140EP - white / BYCQ140EPB - black Dimensions HeightxWidthxDepth mm Standard panels: 50x950x950 / Auto cleaning panels: 130x950x950 / Designer panels: 50x950x950 Weight kg Standard panels: 5.4 / Auto cleaning panels: 10.3 / Designer panels: 5.4 Fan Air flow rate - Cooling Low/High m³/min 8.8/12.5 9.5/13.6 10.5/15.0 10.5/16.5 12.4/22.8 12.4/26.5 19.9/33.0 50Hz Heating Low/High m³/min 8.8/12.5 9.5/13.6 10.5/15.0 10.5/16.5 12.4/22.8 12.4/26.5 19.9/33.0 Air filter Type Resin net Sound pressure level Cooling Low/Nom./High dBA 28.0/29.0/31.0 29.0/31.0/33.0 30.0/33.0/35.0 30.0/34.0/38.0 30.0/37.0/43.0 36.0/41.0/45.0 Heating Low/Nom./High dBA 28.0/29.0/31.0 29.0/31.0/33.0 30.0/33.0/35.0 30.0/34.0/38.0 30.0/37.0/43.0 36.0/41.0/45.0 Refrigerant Type/GWP R-410A/2,087.5 Piping connections Liquid OD mm 6.35 9.52 Gas OD mm 12.70 15.90 Drain VP25 (O.D. 32 / I.D. 25) Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220 Current - 50Hz Maximum fuse amps (MFA) A 16 Control systems Infrared remote control BRC7FA532F* Wired remote control BRC1H81W/S / BRC1D52* *Not applicable for UAE 20 FXZQ-A2VEB Fully flat cassette Unique design in the market that integrates fully flat into the ceiling › Fully flat integration in standard architectural ceiling tiles, leaving only 8mm › Remarkable blend of iconic design and engineering excellence with an elegant finish in white or a combination of silver and white FXZQ-A › Two optional intelligent sensors improve energy efficiency and comfort › 15 class unit especially developed for small or well-insulated rooms, such as hotel bedrooms, small offices, etc. › Individual flap control: flexibility to suit every room layout without changing the location of the unit! BRC1H81W BRC7F530W-S* ŰŰ Optional fresh air intake ŰŰ Standard drain pump with 630mm lift increases flexibility and installation speed 500 mm Indoor unit FXZQ 15A 20A 25A 32A 40A 50A Cooling capacity Total capacity Nom. kW 1.70 2.20 2.80 3.60 4.50 5.60 Heating capacity Total capacity Nom. kW 1.90 2.50 3.20 4.00 5.00 6.30 Power input - 50Hz Cooling Nom. kW 0.043 0.045 0.059 0.092 Heating Nom. kW 0.036 0.038 0.053 0.086 Dimensions Unit HeightxWidthxDepth mm 260x575x575 Weight Unit kg 15.5 16.5 18.5 Casing Material Galvanised steel plate Decoration panel Model BYFQ60C2W1W Colour White (N9.5) Dimensions HeightxWidthxDepth mm 46x620x620 Weight kg 2.8 Decoration panel 2 Model BYFQ60C2W1S Colour SILVER Dimensions HeightxWidthxDepth mm 46x620x620 Weight kg 2.8 Decoration panel 3 Model BYFQ60B2W1 Colour White (RAL9010) Dimensions HeightxWidthxDepth mm 55x700x700 Weight kg 2.7 Decoration panel 4 Model BYFQ60B3W1 Colour WHITE (RAL9010) Dimensions HeightxWidthxDepth mm 55x700x700 Weight kg 2.7 Fan Air flow rate - Cooling Low/High m³/min 6.5/8.5 6.5/8.7 6.5/9.0 7.0/10.0 8.0/11.5 10.0/14.5 50Hz Heating Low/High m³/min 6.5/8.5 6.5/8.7 6.5/9.0 7.0/10.0 8.0/11.5 10.0/14.5 Air filter Type Resin net Sound pressure level Cooling Low/Nom./High dBA 25.5/28.0/31.5 25.5/29.5/32.0 25.5/30.0/33.0 26.0/30.0/33.5 28.0/32.0/37.0 33.0/40.0/43.0 Heating Low/Nom./High dBA 25.5/28.0/31.5 25.5/29.5/32.0 25.5/30.0/33.0 26.0/30.0/33.5 28.0/32.0/37.0 33.0/40.0/43.0 Refrigerant Type/GWP R-410A/2,087.5 Piping connections Liquid OD mm 6.35 Gas OD mm 12.7 Drain VP20 (I.D. 20/O.D. 26) Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220 Current - 50Hz Maximum fuse amps (MFA) A 16 Control systems Infrared remote control BRC7EB530W (standard panel) */ BRC7F530W (white panel) */ BRC7F530S (grey panel)* Wired remote control BRC1H81W/S / BRC1D52* *Not applicable for UAE 21 FXCQ-AVEB 2-way blow ceiling mounted cassette Thin, lightweight design installs easily in narrow corridors › Depth of all units is 620mm, ideal for narrow spaces › Individual flap control: flexibility to suit every room layout without changing the location of the unit! FXCQ20-40A ŰŰ Stylish unit blends easily with any interior. The flaps close entirely when the unit is not operating and there are no air intake grilles visible BRC1H 81W BRC7F5C52* ŰŰ Fresh air intake integrated in the same system thus reducing installation cost as no additional ventilation device is required Fresh air intake opening in casing ŰŰ Branch duct discharge allows to optimize air distribution in irregular shaped rooms or to supply air to small adjacent rooms * Brings in up to 10% of fresh air into the room Main unit ŰŰ Optimum comfort guaranteed with automatic air flow adjustment Branch discharge Main discharge to the required load ŰŰ Standard drain pump with 580mm lift increases flexibility and ŰŰ Maintenance operations can be performed by removing the front installation speed panel 580 mm Indoor unit FXCQ 20A 25A 32A 40A 50A 63A 80A 125A Cooling capacity Total capacity Nom. kW 2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0 Heating capacity Total capacity Nom. kW 2.5 3.2 4.0 5.0 6.3 8.0 10.0 16.0 Power input - 50Hz Cooling Nom. kW 0.031 0.039 0.041 0.059 0.063 0.090 0.149 Heating Nom. kW 0.028 0.035 0.037 0.056 0.060 0.086 0.146 Dimensions Unit HeightxWidthxDepth mm 305x775x620 305x990x620 305x1,445x620 Weight Unit kg 19 22 25 33 38 Casing Material Galvanised steel plate Decoration panel Model BYBCQ40HW1 BYBCQ63HW1 BYBCQ125HW1 Colour Fresh white (6.5Y 9.5/0.5) Dimensions HeightxWidthxDepth mm 55x1,070x700 55x1,285x700 55x1,740x700 Weight kg 10 11 13 Fan Air flow rate - 50Hz Cooling Low/High m³/min 7.5/10.5 8/11.5 8.5/12 10.5/15 11.5/16 18.5/26 22.5/32 Air filter Type Resin net with mold resistance Sound pressure level Cooling Low/Nom./High dBA 28.0/30.0/32.0 29.0/31.0/34.0 30.0/32.0/34.0 31.0/33.0/36.0 31.0/35.0/37.0 32.0/37.0/39.0 33.0/38.0/42.0 38.0/42.0/46.0 Heating Low/Nom./High dBA 28.0/30.0/32.0 29.0/31.0/34.0 30.0/32.0/34.0 31.0/33.0/36.0 31.0/35.0/37.0 32.0/37.0/39.0 33.0/38.0/42.0 38.0/42.0/46.0 Refrigerant Type/GWP R-410A/2,087.5 Piping connections Liquid OD mm 6.35 9.52 Gas OD mm 12.7 15.9 Drain VP25 (O.D. 32 / I.D. 25) Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 Current - 50Hz Maximum fuse amps (MFA) A 16 Control systems Infrared remote control BRC7C52* Wired remote control BRC1H819W/S / BRC1D52* *Not applicable for UAE 22 Auto cleaning filter for concealed ceiling units The unique automatic cleaning filter achieves higher efficiency and comfort with lower maintenance costs airflow direction Reduce running costs ›› Automatic filter cleaning ensures low maintenance costs because the filter is always clean Efficiency profile change for duct indoor unit during operation UNIQUE Up to 20% Patents 100% Energy saved pending Gradual loss of thanks to efficiency due automatic filter to dirty filter cleaning 0% start 6 months 12 months Minimal time required for filter cleaning ›› The dust box can be emptied with a vacuum cleaner for fast and easy cleaning ›› No more dirty ceilings How does it work? Improved indoor air quality ›› Optimum airflow eliminates draft and insulates sound 1 Scheduled automatic filter Superb reliability cleaning 2 Dust collects in a dust box that’s ›› Prevents clogged filters for seamless operation integrated into the unit Unique technology 3 The dust can easily be removed with a vacuum cleaner ›› Unique and innovative filter technology inspired by the Daikin auto cleaning cassette Combination table www.youtube.com/DaikinEurope VRV Specifications BAE20A62 BAE20A82 BAE20A102 Heigth (mm) 210 Width (mm) 830 1,030 1,230 Depth (mm) 188 23 Multi zoning kit for concealed ceiling units The multi-zoning system is a room-by-room controller. It is fitted with motorised dampers, which immediately adapt using Daikin ducted solutions. This system supports control of up to 8 zones via a centralised thermostat located in the main room and individual thermostats for each of the zones. Benefits How does it work? Increased comfort 20°C ›› Increases comfort levels by allowing more individual zone control 19°C -- Up to 8 individual zones can be served thanks to separate modulating dampers Zoning box: -- Individual thermostat for room-by-room or zone-by-zone fully pre-assembled control plenum with 21°C dampers Easy to install ›› Automatic air flow adjustment according to the demand Individual zone thermostats ›› Easy to install, integrates with the Daikin indoor units and system controls Blueface - Airzone Airzone Zone Airzone Zone ›› Time saving as plenum comes fully pre-assembled with dampers, Main Thermostat Thermostat Thermostat and control boards ›› Color graphic interface ›› Graphic interface with ›› Thermostat with buttons ›› Reduces the amount of refrigerant required in the installation for controlling zones low-energy e-ink screen for controlling the ›› Wired communication for controlling zones temperature ›› Radio communication ›› Radio communication Plug and play plenum Concealed ceiling unit Motorized dampers Electronic control panel AZCE6BLUEFACECB AZCE6THINKRB AZCE6LITERB Compatibility FXSQ-A Number of Dimensions motorised dampers Reference H x W x D (mm) • • • • • • • • • • • • • • Standard Ceiling • • Void • • • • • • • • • • • • • • Compact Ceiling • • • • Void • • • • • • • 24 FXDQ-A3VEB Slim concealed ceiling unit rear suction Slim design for flexible installation › Compact dimensions, can easily be mounted in a ceiling void of only 240mm outblow SERIES A (15, 20, 25, 32) bottom suction 200 mm FXDQ15-32A3 700 mm 50 mm ŰŰ Medium external static pressure up to 44Pa facilitates unit use with flexible ducts of varying lengths ŰŰ Discretely concealed in the wall: only the suction and discharge grilles are visible ŰŰ 15 class unit especially developed for small or well-insulated rooms, such as hotel bedrooms, small offices, etc. BRC1H 81W BRC4C65* ŰŰ Auto cleaning filter option ensures maximum efficiency, comfort and reliability by regular filter cleaning ŰŰ Multi zoning kit allows multiple individually-controlled climate zones to be served by one indoor unit ŰŰ Flexible installation, as the air suction direction can be altered from rear to bottom suction ŰŰ Standard drain pump with 750mm lift increases flexibility and installation speed 750 mm Auto cleaning filter option Indoor unit FXDQ 15A3 20A3 25A3 32A3 40A3 50A3 63A3 Cooling capacity Total capacity Nom. kW 1.70 2.20 2.80 3.60 4.50 5.60 7.10 Heating capacity Total capacity Nom. kW 1.90 2.50 3.20 4.00 5.00 6.30 8.00 Power input - 50Hz Cooling Nom. kW 0.071 0.078 0.099 0.110 Heating Nom. kW 0.068 0.075 0.096 0.107 Required ceiling void > mm 240 Dimensions Unit HeightxWidthxDepth mm 200x750x620 200x950x620 200x1,150x620 Weight Unit kg 22.0 26.0 29.0 Casing Material Galvanised steel Fan Air flow rate - 50Hz Cooling Low/High m³/min 6.4/7.5 6.4/8.0 8.5/10.5 10.0/12.5 13.0/16.5 External static Nom./High Pa 10/30.0 15/44.0 pressure - 50Hz Air filter Type Removable / washable Sound pressure level Cooling Low/Nom./High dBA 27.0/31.0/32.0 27.0/31.0/33.0 28.0/32.0/34.0 29.0/33.0/35.0 30.0/34.0/36.0 Refrigerant Type/GWP R-410A/2,087.5 Piping connections Liquid OD mm 6.35 9.52 Gas OD mm 12.7 15.9 Drain VP20 (I.D. 20/O.D. 26) Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220 Current - 50Hz Maximum fuse amps (MFA) A 16 Control systems Infrared remote control BRC4C65 */ BRC4C66* Wired remote control BRC1H81W/S / *BRC1D52* *Not applicable for UAE 25 FXSQ-A2VEB Concealed ceiling unit with medium ESP Slimmest yet most powerful medium static pressure unit outblow on the market rear › Slimmest unit in class, only 245mm (300mm built-in height) and suction therefore narrow ceiling voids are no longer a challenge bottom suction FXSQ-A 245 mm ŰŰ Quiet operation: down to 25dBA sound pressure level ŰŰ Medium external static pressure up to 150Pa facilitates using flexible ducts of varying lengths ŰŰ Possibility to change ESP via wired remote control allows optimisation of the supply air volume BRC1H81W BRC4C65* ŰŰ Discretely concealed in the wall: only the suction and discharge grilles are visible ŰŰ 15 class unit especially developed for small or well-insulated ŰŰ Standard built-in drain pump with 625mm lift increases flexibility rooms, such as hotel bedrooms, small offices, etc. and installation speed ŰŰ Multi zoning kit allows multiple individually-controlled climate zones to be served by one indoor unit 625 mm ŰŰ Optional fresh air intake ŰŰ Flexible installation: air suction direction can be altered from rear to bottom suction and choice between free use or connection to optional suction grilles ////////////////////////////////////////// ////////////////////////////////////////// ////////////////////////////////////////// For free use into a false For connecting onto a For direct connection to ceiling suction canvas Daikin panel (not supplied by Daikin) (via EKBYBSD kit) External static pr essure (Pa) Automatic Airflow Adjustment function Automatically selects the most appropriate fan curve to achieve the units’ nominal air flow within ±10% Fan characteristic curves Why? After installation the real ducting will frequently differ from the initially calculated air flow resistance the real air flow may be much lower or higher than nominal , leading to a lack of capacity or uncomfortable air temperature Duct resistance curves matic adjustment ) Automatic Airflow Adjustment function will adapt the unit’s fan speed to any ducting automatically (10 or more fan curves are available on every model), making installation much faster ± /min) Indoor unit FXSQ 15A 20A 25A 32A 40A 50A 63A 80A 100A 125A 140A Cooling capacity Total capacity Nom. kW 1.70 2.20 2.80 3.60 4.50 5.60 7.10 9.00 11.20 14.00 16.00 Heating capacity Total capacity Nom. kW 1.90 2.50 3.20 4.00 5.00 6.30 8.00 10.0 12.5 16.0 18.0 Power input - 50Hz Cooling Nom. kW 0.090 0.096 0.151 0.154 0.188 0.213 0.290 0.331 0.386 Heating Nom. kW 0.086 0.092 0.147 0.150 0.183 0.209 0.285 0.326 0.382 Dimensions Unit HeightxWidthxDepth mm 245x550x800 245x700x800 245x1,000x800 245x1,400x800 245x1,550x800 Weight Unit kg 23.5 24.0 28.5 29.0 35.5 36.5 46.0 47.0 51.0 Casing Material Galvanised steel plate Fan Cooling Low/High m³/min 6.5/8.7 6.5/9.0 7.0/9.5 11.0/15.0 11.0/15.2 15.0/21.0 16.0/23.0 23.0/32.0 26.0/36.0 28.0/39.0 50Hz Heating Low/High m³/min 6.5/8.7 6.5/9.0 7.0/9.5 11.0/15.0 11.0/15.2 15.0/21.0 16.0/23.0 23.0/32.0 26.0/36.0 28.0/39.0 External static Nom./High Pa 30/150 40/150 50/150 pressure - 50Hz Type Resin net Sound pressure level Cooling Low/Nom./High dBA 25.0/28.0/29.5 25.0/28.0/30.0 26.0/29.0/31.0 29.0/32.0/35.0 27.0/30.0/33.0 29.0/32.0/35.0 31.0/34.0/36.0 33.0/36.0/39.0 34.0/38.0/41.5 Heating Low/Nom./High dBA 26.0/29.0/31.5 26.0/29.0/32.0 27.0/30.0/33.0 29.0/34.0/37.0 28.0/32.0/35.0 30.0/34.0/37.0 31.0/34.0/37.0 33.0/37.0/40.0 34.0/38.5/42.0 Refrigerant Type/GWP R-410A/2,087.5 Piping connections Liquid OD mm 6.35 9.52 Gas OD mm 12.7 15.9 Drain VP20 (I.D. 20/O.D. 26), drain height 625 mm Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220 Current - 50Hz Maximum fuse amps (MFA) A 16 Control systems Infrared remote control BRC4C65* Wired remote control BRC1H81W/S/ BRC1D52* *Not applicable for UAE 26 FXMQ-P7VEB9 / FXMQ-MAVE Concealed ceiling unit with high ESP Ideal for large sized spaces FXMQ-P7: ESP up to 200 Pa outblow rear ŰŰ Possibility to change ESP via wired remote control allows suction optimisation of the supply air volume bottom ŰŰ High external static pressure up to 200Pa facilitates extensive duct FXMQ50-80P7 suction and grille network ŰŰ Discretely concealed in the wall: only the suction and discharge grilles are visible ŰŰ Fresh air intake integrated in the same system thus reducing installation cost as no additional ventilation device is required Fresh air intake opening in casing Fresh air intake position BRC1H81W BRC4C65* ŰŰ Standard built-in drain pump with 625mm lift increases flexibility and installation speed 625 mm * Brings in up to 10% of fresh air into the room ŰŰ Flexible installation, as the air suction direction can be altered from rear to bottom suction FXMQ-MA: ESP up to 270 Pa › High external static pressure up to 270Pa facilitates extensive duct and grille network › Discretely concealed in the wall: only the suction and discharge grilles are visible › Large capacity unit: up to 31.5 kW heating capacity External static pr essure (Pa) Automatic Airflow Adjustment function Automatically selects the most appropriate fan curve to achieve the units’ nominal air flow within ±10% Fan characteristic curves Why? After installation the real ducting will frequently differ from the initially calculated air flow resistance the real air flow may be much lower or higher than nominal , leading to a lack of capacity or uncomfortable air temperature Duct resistance curves matic adjustment ) Automatic Airflow Adjustment function will adapt the unit’s fan speed to any ducting automatically (10 or more fan curves are a vailable on every model), making installation much faster ± /min) Indoor unit FXMQ Cooling capacity Total capacity Nom kW 22.4 28 Heating capacity Total capacity Nom kW 25 31.5 Cooling Nom. kW 1.294 1.465 Heating Nom. kW 1.294 1.465 Required ceiling void > mm - Dimensions Unit HeightxWidthxDepth mm Weight Unit kg 137 Casing Material Galvanised steel plate Decoration panel Model - Colour - Dimensions HeightxWidthxDepth mm -x-x- Weight kg - Fan Air Flow Rate- Cooling Low/High m³/min Heating Low/High m³/min -/- External static Nom./High Pa Air filter Type Resin net - Sound pressure Cooling Low/High dBA level Heating Low/High dBA -/- Refrigerant Type/GWP Piping connections Liquid OD mm Gas OD mm Drain Power supply Phase/Frequency/Voltage Hz/V Maximum fuse amps (MFA) A Control systems Infrared remote control Wired remote control *Not applicable for UAE 27 FXAQ-PV / PVER Wall mounted unit For rooms with no false ceilings or free floor space › Flat, stylish front panel blends easily within any interior décor and is easier to clean › Can easily be installed in both new and refurbishment projects › The air is comfortably spread up- and downwards thanks to 5 different discharge angles that can be programmed via the remote control FXAQ-PV › Maintenance operations can be performed easily from the front of the unit BRC1H81W BRC7EA618* Indoor unit FXAQ 20PV 25PV 32PV 40PVER 50PVER 63PVER Cooling capacity Total capacity Nom. kW 2.2 2.8 3.6 4.5 5.6 7.1 Heating capacity Total capacity Nom. kW 2.5 3.2 4.0 5.0 6.3 8.0 Power input - 50Hz Cooling Nom. kW 0.02 0.03 0.02 0.03 0.05 Heating Nom. kW 0.03 0.04 0.02 0.04 0.06 Dimensions Unit HeightxWidthxDepth mm 290x795x238 290x1,050x238 Weight Unit kg 11 14 Fan Cooling Low/High m³/min 4,517.5 5/8 5.5/8.5 9/12 12/15 14/19 50Hz Type Washable resin net Sound pressure level Cooling Low/High dBA 31/35 31/36 31/38 34/39 37/42 41/47 Heating Low/High dBA 31/35 31/36 31/38 34/39 37/42 41/47 Refrigerant Type/GWP R-410A/2,087.5 Piping connections Liquid OD mm 6.35 9.52 Gas OD mm 12.7 15.9 Drain VP13 (I.D. 15/O.D. 18) Power supply Phase/Frequency/Voltage Hz/V 1~/50/60Hz/220-240/220V Current - 50Hz Maximum fuse amps (MFA) A 15 Control systems Infrared remote control BRC7EA618* / BRC7EA619* Wired remote control BRC1H81W/S / BRC1D52* *Not applicable for UAE 28 FXHQ-AVEB Ceiling suspended unit For wide rooms with no false ceilings nor free floor space › Ideal for comfortable air flow in wide rooms thanks to Coanda effect: up to 100° discharge angle FXHQ63A ŰŰ Even rooms with ceilings up to 3.8m can be heated up or cooled down very easily without capacity loss BRC1H 81W BRC7G53* ŰŰ Can easily be installed in both new and refurbishment projects ŰŰ Can easily be mounted in corners and narrow spaces, as it only needs 30mm lateral service space //////////////////////////////////////////// ////////////////////// ////////////////////// //////////////////////////////////// Air outlet 30 or more ≥300 (Service Air inlet space) 30 or more //////////////////////////// (Service space) Obstruction ŰŰ Fresh air intake integrated in the same system thus reducing installation cost as no additional ventilation device is required Fresh air intake opening in casing * Brings in up to 10% of fresh air into the room ŰŰ Reduced energy consumption thanks to specially developed DC fan motor and drain pump ŰŰ Stylish unit blends easily with any interior. The flaps close entirely when the unit is not operating and there are no air intake grilles visible Indoor unit FXHQ 32A 63A 100A Cooling capacity Total capacity Nom. kW 3.6 7.1 11.2 Heating capacity Total capacity Nom. kW 4.0 8.0 12.5 Power input - 50Hz Cooling Nom. kW 0.107 0.111 0.237 Heating Nom. kW 0.107 0.111 0.237 Dimensions Unit HeightxWidthxDepth mm 235x960x690 235x1,270x690 235x1,590x690 Weight Unit kg 24 33 39 Casing Material Resin Fan Air flow rate - Cooling Low/High m³/min 10.0/14.0 14.0/20.0 19.0/29.5 50Hz Heating Low/High m³/min 10.0/14.0 14.0/20.0 19.0/29.5 Air filter Type Resin net with mold resistance Sound pressure level Cooling Low/Nom./High dBA 31.0/34.0/36.0 34.0/35.0/37.0 34.0/37.0/44.0 Heating Low/Nom./High dBA 31.0/34.0/36.0 34.0/35.0/37.0 34.0/37.0/44.0 Refrigerant Type/GWP R-410A/2,087.5 Piping connections Liquid OD mm 6.35 9.52 Gas OD mm 12.7 15.9 Drain VP20 (I.D. 20/O.D. 26) Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 Current - 50Hz Maximum fuse amps (MFA) A 16 Control systems Infrared remote control BRC7G53* Wired remote control BRC1H81W/S/ BRC1D52* *Not applicable for UAE 29 FXUQ-AVEB 4-way blow ceiling suspended unit Unique Daikin unit for high rooms with no false ceilings or free floor space › Even rooms with ceilings up to 3.5m can be heated up or cooled down very easily without capacity loss › Can easily be installed in both new and refurbishment FXUQ-A projects › Individual flap control: flexibility to suit every room layout without changing the location of the unit! UNIQUE BRC1H81W BRC7C58 ŰŰ Stylish unit blends easily with any interior. The flaps close entirely when the unit is not operating and there are no air intake grilles visible ŰŰ Optimum comfort guaranteed with automatic air flow adjustment to the required load ŰŰ 5 different discharge angles between 0 and 60°can be programmed via the remote control ŰŰ Standard drain pump with 500mm lift increases flexibility and installation speed VP20 ≤500 ////////////////////////////////////////////// Indoor unit FXUQ 71A 100A Cooling capacity Total capacity Nom. kW 8.0 11.2 Heating capacity Total capacity Nom. kW 9.0 12.5 Power input - 50Hz Cooling Nom. kW 0.090 0.200 Heating Nom. kW 0.073 0.179 Dimensions Unit HeightxWidthxDepth mm 198x950x950 Weight Unit kg 26 27 Casing Material Resin Fan Air flow rate - Cooling Low/High m³/min 16.0/22.5 21.0/31.0 50Hz Heating Low/High m³/min 16.0/22.5 21.0/31.0 Air filter Type Resin net with mold resistance Sound pressure level Cooling Low/Nom./High dBA 36.0/38.0/40.0 40.0/44.0/47.0 Heating Low/Nom./High dBA 36.0/38.0/40.0 40.0/44.0/47.0 Refrigerant Type/GWP R-410A/2,087.5 Piping connections Liquid OD mm 9.52 Gas OD mm 15.9 Drain I.D. 20/O.D. 26 Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220-230 Current - 50Hz Maximum fuse amps (MFA) A 16 Control systems Infrared remote control BRC7C58* Wired remote control BRC1H81W/S / BRC1D52* *Not applicable for UAE 30 FXNQ-A2VEB Concealed floor standing unit Designed to be concealed in walls › Discretely concealed in the wall: only the suction and discharge grilles are visible › Requires very little installation space as the depth is only 200mm2 FXNQ-A BRC1H81W BRC4C65* ŰŰ Its low height (620 mm) enables the unit to fit perfectly beneath a window ŰŰ High ESP allows flexible installation Indoor unit FXNQ 20A 25A 32A 40A 50A 63A Cooling capacity Total capacity Nom. kW 2.20 2.80 3.60 4.50 5.60 7.10 Heating capacity Total capacity Nom. kW 2.50 3.20 4.00 5.00 6.30 8.00 Power input - 50Hz Cooling Nom. kW 0.071 0.078 0.099 0.110 Heating Nom. kW 0.068 0.075 0.096 0.107 Dimensions Unit HeightxWidthxDepth mm 620 / 720x790x200 620 / 720x990x200 620 / 720x1,190x200 Weight Unit kg 23.5 27.5 32.0 Casing Material Galvanised steel plate Fan Air flow rate - Cooling Low/High m³/min 6.4/8.0 8.5/10.5 10.0/12.5 13.0/16.5 50Hz Heating Low/High m³/min 6.4/8.0 8.5/10.5 10.0/12.5 13.0/16.5 External static Nom./High Pa 10/41.0 10/42.0 15/52.0 15/59.0 15/55.0 pressure - 50Hz Air filter Type Resin net Sound pressure level Cooling Low/Nom./High dBA 27.0/28.5/30.0 28.0/30.0/32.0 29.0/31.0/33.0 32.0/33.0/35.0 Heating Low/Nom./High dBA 27.0/28.5/30.0 28.0/30.0/32.0 29.0/31.0/33.0 32.0/33.0/35.0 Refrigerant Type/GWP R-410A/2,087.5 Piping connections Liquid OD mm 6.35 9.52 Gas OD mm 12.7 15.9 Drain VP20 (I.D. 20/O.D. 26) Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220 Current - 50Hz Maximum fuse amps (MFA) A 16 Control systems Infrared remote control BRC4C65* Wired remote control BRC1D52* / BRC1H81W/S *Not applicable for UAE 31 FXLQ-P2VEB Floor standing unit For perimeter zone air conditioning › Unit can be installed as free standing model by use of optional back plate › Its low height enables the unit to fit perfectly beneath a window › Stylish modern casing finished in pure white (RAL9010) and iron grey (RAL7011) blends easily with any interior › Requires very little installation space FXLQ20,25P /////////////////////////////////////////////////////////// /////////////////////////////////////////////////////////// ////////////////// BRC1H 81W BRC4C65* //////////////////////////////// //////////////////////////////// Floor standing Wall mounted ŰŰ Wall mounted installation facilitates cleaning beneath the unit where dust tends to accumulate ŰŰ Wired remote control can easily be integrated in the unit Indoor unit FXLQ 20P 25P 32P 40P 50P 63P Cooling capacity Total capacity Nom. kW 2.2 2.8 3.6 4.5 5.6 7.1 Heating capacity Total capacity Nom. kW 2.5 3.2 4.0 5.0 6.3 8.0 Power input - 50Hz Cooling Nom. kW 0.05 0.09 0.11 Heating Nom. kW 0.05 0.09 0.11 Dimensions Unit HeightxWidthxDepth mm 600x1,000x232 600x1,140x232 600x1,420x232 Weight Unit kg 27 32 38 Fan Air flow rate Cooling Low/High m³/min 6.0/7 6.0/8 8.5/11 11.0/14 12.0/16 - 50Hz Air filter Type Resin net Sound pressure level Cooling Low/High dBA 32/35 33/38 34/39 35/40 Heating Low/High dBA 32/35 33/38 34/39 35/40 Refrigerant Type/GWP R-410A/2,087.5 Piping connections Liquid OD mm 6.35 9.52 Gas OD mm 12.7 15.9 Drain O.D. 21 (Vinyl chloride) Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220 Current - 50Hz Maximum fuse amps (MFA) A 15 Control systems Infrared remote control BRC4C65* Wired remote control BRC1H519W/ BRC1D52* *Not applicable for UAE 32 ECPEN15-206A.indd 11 24/03/15 11:48 Ventilation range Why use VRV condensing units for connection to air handling units? Outside air = 46°C High ciency Fresh air supplied at 21°C. The temperature For most of the time, the AHU will be in cooling mode. By combining a difference with the outdoor air is pre- heat wheel with the AHU, energy bills can be reduced by cooled by the heat wheel. recovering the cool air exhausted to the atmosphere. When heating is required in winter conditions, we can simply package it with Daikin heat pumps which are renowned for their high efficiency. Fresh air can be heated in cases when the air is too cold to be supplied untreated. Fast response to changing loads resulting in high comfort levels Daikin VRV units respond rapidly to fluctuations in supply air temprerature, resulting in steady indoor temperature and high comfort levels for the end user. The ultimate package is Easy Design the VRV range combined with an AHU that is designed to provide and Installation the perfect indoor conditions for the year round cooling demand in the Middle East, while reducing running cost. The system is easy to design and install since no additional water systems such as boilers, chillers, buffer, tanks and gas connections etc. are required. This also reduces both the Daikin Fresh air package total system investment and running cost. VRV IV+ condensing unit (single or multi) gas liquid Factory fitted and welded fresh air package Expansion valve Electronic interface (EKEXV) (EKEQ) Capacity: Up to 269 kW (Nominal Capacity) - by 4x24 HP OU. Expansion Value Sizes: 50 - 63 - 80 - 100 - 125 - 140 - 200 - 250 - 400 -500 Product Range /hr ) Type Product name 32,000 Components of indoor air quality Ventilation VAM-FC Heat recovery Ventilation Heat recovery Air handling DX total fresh Air processing units air package Filtration 33 ECPEN15-206A.indd 12 24/03/15 11:48 In order to maximize installation flexibility, 4 types of control systems are offered Control w: Off the shelf control of air temperature (discharge Control y: Control of refrigerant (Te/Tc) temperature via Daikin temperature, suction temperature, room temperature) via any control (no DDC controller needed) with 3rd party thermostat DDC controller using a proportional 0~10V algorithm for capacity (Daikin control for field settings and error indication) control Control z: Control of air temperature (suction temperature, room Control x: Precise control of air temperature (discharge temperature) via Daikin control (no DDC controller needed) temperature, suction temperature, room temperature) requiring a pre-programmed DDC controller (for special applications) using a proportional 0~10V algorithm for capacity control Possibility W (Td/Tr control): Possibility X (Td/Tr control): Air temperature control via DDC controller Precise air temperature control via DDC controller Room temperature is controlled as a function of the air handling Room temperature is controlled as a function of the air handling unit suction or discharge air (customer selection). The DDC unit suction or discharge air (customer selection). The DDC controller is translating the temperature difference between set controller is translating the temperature difference between set point and air suction temperature (or air discharge temperature or point and air suction temperature (or air discharge temperature room temperature) into a proportional 0-10V signal or room temperature) into a reference voltage (0-10V) which is which is transferred to the Daikin control box (EKEQFCBA). transferred to the Daikin control box (EKEQFCBA). This reference This voltage controls the compressor frequency. voltage will be used as the main input value for the compressor frequency control. Ts Ts Te Td Te Td Daikin AHU Daikin AHU control box: control box: DDC EKEQFCBA DDC Tr Room EKEQMCB* Tr Room Possibility Y (Te/Tc control): Possibility Z (Ts/Tr control): By fixed evaporating /condensing temperature Control your AHU just like a VRV indoor unit with 100% fresh air A fixed target evaporating temperature of between 3°C and (BRC1D52** or BRC1H81W/S - optional) 12°C can be set by the customer. In this case, room temperature is Set point can be fixed via standard Daikin infrared remote control. only indirectly controlled. The cooling load is determined from Remote ON/OFF can be achieved the actual evaporating temperature (i.e. load to the heat by an optional adapter KRP4A51. exchanger). A Daikin infrared remote control (BRC1D52** or No external DDC controller should be connected. The cooling load is BRC1H81W/S - optional) can be connected for error indication. determined from the air suction temperature and set point on the Daikin controller. ON / OFF KRP4A51 Daikin Ts AHU Ts Te control box: Te Td Td EKEQFCBA Daikin AHU Tr Room control box: EKEQMCB Tr Room BRC1D52** BRC1H81W/S BRC1D52** BRC1H81W/S Ts = Air suction temperature Tr = Room temperature AHU = Air Handling Unit Td = Air discharge temperature Te = Evaporating temperature DDC = Digital Display Controller Option kit Features DDC controller is required Possibility w temperature control using air suction or air discharge temperature EKEQFCBA DDC and Microtech controller is required Possibility x Precise Temperature control using air suction or air discharge temperature Possibility y Using fixed evaporating temperature, no set point can be set using remote control EKFQMCBA* Using Daikin infrared remote control ** or BRC1H81W/S Possibility z Temperature control using air suction temperature * EKEQMCB (for ’multi’ application) **Not applicable for UAE 34 Control Systems 36 New premium Individual control systems design wired 40 remote control Centralised remote control / Unified ON/OFF control / Schedule timer 42 43 Table t with Daikin Cloud Service 44 47 Standard protocol interfaces 48 50 51 51 EKPCCAB3 52 Daikin Cloud Service for commercial DX systems 53 Other devises 55 56 35 Control Solutions Summary rious control solution adapted to the requirements of even the most demanding commercial application. › Basic control solutions for those customers with few requirements › Advanced control solutions for those customers that expect and limited budget Daikin to deliver a mini BMS solution, including advance › Integrating control solutions for those customers that would like to integrate Daikin units into their existing BMS system Shop Unit control Unit control Integrating control Advanced control Tablet BRP069* BRC519W/ Online RTD-20 RTD-Net KLIC-DI EKMBDXA DCC601A51 DCM601A51 S/K(7) controller Smart phone 1 remote 1 gateway 1 gateway for 1 gateway for 1 gateway for 1 unit for 1 iTM for 64 control for up controller for for 1 indoor 1 indoor unit 1 indoor unit max. 64 indoor 32 indoor indoor unit(s) to 50 indoor 1 indoor unit unit (group) (group) unit(s) (groups) unit(s) (5) (groups) (1) units (group) & 10 outdoors Automatic control of A/C Limit control possibilities for shop staff Create zones within the shop Interlock with eg. Alarm, PIR sensor (limited) Integrate Daikin units into existing BMS via Modbus Integrate Daikin units into existing BMS via KNX Integrate Daikin units into existing BMS via HTTP Monitor energy consumption (4) (2) Advanced energy management (2) Allows free cooling Integrate Daikin products cross pillars into Daikin BMS Integrate third party products into Daikin BMS Online control (2) (3) Manage multiple sites (2) (3) (1) 7 iTM plus adapters (DCM601A52) can be added to have 512 indoor groups and 80 outdoor (systems) (2) Via Daikin cloud service (3) Through own IT set-up (not Daikin cloud server) (4) Not available on all indoors (5) Up to 10 DCC601A51 can be combined as a single site on Daikin Cloud Service Hotel Unit control Integrating control Advanced control BRC1H81W/S RTD-HO KLIC-DI DCM601A51 1 remote controller 1 gateway for 1 1 gateway for 1 1 iTM for 64 indoor for 1 indoor unit indoor unit (group) indoor unit unit(s) (groups) (1) (group) Hotel guest can control & monitor basic functionalities from his room (3) Limit control possibilities for hotel guests Interlock with window contact (2) Interlock with key-card (2) Integrate Daikin units into existing BMS via Modbus Integrate Daikin units into existing BMS via KNX Integrate Daikin units into existing BMS via HTTP Monitor energy consumption Advanced energy management Integrate Daikin products cross pillars into Daikin BMS Integrate third party products into Daikin BMS Online control (1) : 7 iTM plus adapters (DCM601A52) can be added to have 512 indoor groups and 80 outdoor (systems) (2) Via BRP7A51 adapter (3) requires KNX compatible controller 36 Office Unit control Integrating control Advanced control Tablet DMS502A51 / BRC1H81W/S EKMBDXA DMS504B51 DCC601A51 DCM601A51 DAM412B51 1 gateway for max. 1 gateway for 1 remote controller 1 gateway for 64 indoor unit(s) 128 indoor unit(s) 1 unit for 32 indoor 1 iTM for 64 indoor for 1 indoor unit 64 indoor unit(s) (groups) & 10 (groups), 20 out- unit(s) (groups) (5) unit(s) (groups) (1) (group) (groups) outdoors doors (2) Automatic control of A/C Centralised control for management Integrate Daikin units into existing BMS via Modbus Integrate Daikin units into existing BMS via HTTP Integrate Daikin units into existing BMS via LonTalk Integrate Daikin units into existing BMS via BACnet Energy consumption read out Monitor energy consumption (4) Advanced energy management (4) Integrate Daikin cross pillar products into Daikin BMS Integrate third party products into Daikin BMS Online control (4) Manage multiple sites (4) (5) (1) 7 iTM plus adapters (DCM601A52) can be added to have 512 indoor groups and 80 outdoor (systems) (2) extension needed to go to 256 indoor unit(s) (groups), 40 outdoors (3) ON/OFF only (4) Via Daikin cloud service (5) Through own IT set-up (not Daikin cloud sever) (5) Up to 10 DCC601A51 can be combined as a single site on Daikin Cloud Service Home Automation Unit Integrating Advanced control control control Tablet BRC1H81 RTD-Net KLIC-DI DCC601A51 W/S 1 remote 1 gateway for 1 gateway for 1 unit for controller for 1 indoor unit 1 indoor unit 32 indoor 1 indoor unit (group) unit(s) (3) (group) Automatic control of A/C Limit control possibilities for children Create zones within the home Interlock with eg. Alarm, PIR sensor (limited) Integrate Daikin units into existing BMS via Modbus Integrate Daikin units into existing BMS via KNX Monitor energy consumption (1) (2) (1) Not available for all indoors (2) via Daikin cloud service (3) Up to 10 DCC601A51 can be combined as a single site on Daikin Cloud Service 37 Experience a new way of air conditioning control and commissioning Silver BRC1H81S White BRC1H81W User-friendly wired remote controller with premium design A complete redesigned controller focused on enhancing user experience • Sleek and elegant design • Intuitive touch button control • 2 colors to match any interior design • Compact, only 85x85mm • Advanced settings and commissioning via smartphone 38 Madoka Assistant Simplifies the advanced settings such as schedule or set point limitation Visual interface simplifies advanced settings such as schedule setting, energy saving activation, setting restrictions, etc. Easy and quick commissioning, saves time and cost for installers Featuring Bluetooth® low energy technology Easy setting of schedules Advanced user settings Installer settings Field settings 39
Enter the password to open this PDF file:
-
-
-
-
-
-
-
-
-
-
-
-