1 | GRUNDFOS ALLDOS | DISINFECTION GRUNDFOS ALLDOS DISINFECTION ALLDOS DISINFECTION SYSTEMS with Chlorine Gas Content Page Applications 4-5 Geco 103-100 compact dosing unit 1 6 4 6 Vacuum regulator and dosing unit in one device for direct mounting on a chlorine gas cylinder • Complete with injector, vacuum line and spare sealings • C 111/C 113 dosing system 3 5 2 2 4 6 7 Continuous chlorine gas dosing without interrupting the process for manual or automatic control • 2 vacuum regulators for mounting on chlorine gas cylinders • Dosing unit for separate wall mounting • The fi rst cylinder being empty, the U 189 device changes immediately over to the next vacuum regulator at the full chlorine cylinder • C 117/GS 146 dosing system 8 Continuous gas dosing without interrupting the process for manual or automatic control • 2 vacuum regulators for mounting on gas drums, liquid traps avoid the penetration of lique fi ed gas • Separate installation of several dos- ing units • If the fi rst drum is empty, the device changes immediately over to the next vacuum regulator at the full gas drum • The safety valve avoids excess pres- sure in the vacuum lines leaving the dosing system • 1 103-100 9 Display unit for empty signal 2 111-102/111-202 10 Gas sensor 3 113-110 11 Gas warning unit Gasdetect 4 Injector 545 12 Flowmeter with current signal output 5 Vacuum change-over unit U 189 13 Compact measuring system Conex Compact 6 Chlorine gas absorption cylinder 524 7 Vacuum regulator with liquid trap 8 Dosing unit with manual rate valve 8a Dosing unit with electric servomotor 8b Dosing untit with electric servomotor and current input 8b 8a 8 5 9 11 10 6 12 7 7 13 4 3 | GRUNDFOS ALLDOS | DISINFECTION 1 Chlorine drum 5 Nitrogen fl ushing device 14 Chlorine gas sensor (Alldos safety system Gasdetect) 1a Chlorine drum balance 6 Chlorine evaporator 2 Control for the pneumatic chlorine drum quick-action stop valves 7 Pressure reducing valve and fi lter 15 Optical and acoustic alarm device 8 GS 141-148 vacuum regulator 16 Suction nozzle to the chlorine gas neutralization sytem 3 Chlorine drum lifting device 9 GS 141-145 gas dosing system 3a Lifting beam 10 High-capacity injector 17 Central control panel with computer interface 3b Spring balance for cranes 11 Motive water booster pump 3c Chain hoist 12 Flowmeter with 4-20 mA output 18 Sprinkling system 4 Automatic change-over device 13 Injection unit GS 140 Series High capacity disinfection system These innovative disinfection sytems dis- pose of modern sensors and microproc- essor electronics for the measurement of the chlorine concentration and the control of the dosing fl ow. A multitude of sensors offer in connection with PLC extensive possibilities of monitoring and early detection of faults in automated systems, and thus provide the utmost process safety. Structure Vacuum regulator with gas inlet valve and safety valve for installation in a gas tank room Dosing unit with fl owmeter, linear ad- justment valve and differential pressure controller for installation on the fl oor or at the wall Modern optional equipment for control, regulation, full-automatic operation and control Injectors especially developed for the new dosing system with utmost ef- fi ciency • • • • 9-10 Accessories Change-over devices Chlorine header line Pressure reducing valve Injection Units Chlorine gas absorption cylinder Injectors Combined liquid chlorine trap Chlorine gas fi lter Drum support • • • • • • • • • 11-15 16 18 16 2 3b 3c 4 5 1 1a 14 17 11 10 12 13 16 15 17 9 8 7 6 16 18 16 2 3b 3c 4 5 1 1a 14 17 11 10 12 13 16 15 17 9 8 7 6 16 18 16 2 3b 3c 4 5 1 1a 14 17 11 10 12 13 16 15 17 9 8 7 6 16 18 16 2 3b 3c 4 5 1 1a 14 17 11 10 12 13 16 15 17 9 8 7 6 16 18 16 2 3b 3c 4 5 1 1a 14 17 11 10 12 13 16 15 17 9 8 7 6 16 18 16 2 3b 3c 4 5 1 1a 14 17 11 10 12 13 16 15 17 9 8 7 6 Chlorine gas disinfection systems are used for drinking water treatment. 5 | GRUNDFOS ALLDOS | DISINFECTION Applications Drinking water The most important application area for gas disinfection systems is in the drinking water sector, including the disinfection of raw water as well as the fi nal disinfection after treatment process. Pool water disinfection Every swimmer adds 1.000.000 to 1.000.000.000 microorganisms to the water. The water itself contains microorganisms, as well. Chlorine gas is the effective and eco- nomic means for the disinfection of swimming pool water. Chlorine gas disinfection systems can be used for various purposes: Process water disinfection Chlorine gas can also be used for disinfection of process water to ensure that micro- bial contamination transmission from water is minimized. Cooling water treatment By disinfecting the cooling water you remove microorganisms that can affect the system. Waste water disinfection Waste water disinfection includes disinfection of industrial waste water and munici- pal waste water. It protects the public from potential exposure to pathogenic microor- ganisms that would otherwise be present in wastewater. GECO 103-100 compact dosing unit Technical data Medium Chlorine gas Capacity range 5 - 100 g/h, 10 - 250 g/h, 25 - 500 g/h, 50 - 1000 g/h, 100 - 2000 g/h, 150 - 3000 g/h, 400 - 4000 g/h Adjustment ratio 1 : 20 Accuracy +/- 4 % Measuring device According to the fl oater principle, measuring tube 70 mm Empty indication Optical signal for lack of chlorine, automatic Materials Enclosure PVC Inlet valve Silver/PTFE, special alloy Springs Hastelloy C coated Diaphragm FEP Rate valve PVC O-rings Viton B Yoke Cast, nickel plated Connections Pressure gas USA yoke, option: union nut Vacuum safety line PE hose 8/11 Injector water connections ¾” hose / ¾” NPT up to 1000 g/h 1” hose / 1” NPT up to 2000 g/h 1 ¼” hose / 1 ¼” NPT up to 4000 g/h P max (water) Motive water pressure at the injector: 16 bar Backpressure at the injector outlet: 5 bar Weight 1,3 up to 2 kg Geco 103-100 variants Capacity Injector connection 5 - 100 g/h ¾ ” hose / ¾” NPT 10 - 250 g/h 25 - 500 g/h 50 - 100 g/h 100 - 2000 g/h 1” hose / 1” NPT 150 - 3000 g/h 1 ¼” hose / 1 ¼” NPT 400 - 4000 g/h 131.7 82.4 92 31.4 ca. 197 101 71.1 14 40.3 126 146 63 max. 168 Measurements in mm Optional connections Union nut 1” Union nut G 5/8 Union nut G ¾” Optional accessories Manometer 0-16 bar, NG 63 Residual pressure control 2 bar Liquid trap, heating 230 V, cable with Euro plug • • • • • • 7 | GRUNDFOS ALLDOS | DISINFECTION C 111/C 113 dosing system This systems consists of Vacuum regulator C 111-202 Single dosing regulator C 113-310 or 390 Vacuum regulator C 111-202 Connection Capacity union nut 1” max. 4 kg/h With inlet valve and safety overpressure valve Prepared for manometer Optical empty indication 25 m of vacuum line (PE hose 8/11) with connections With gaskets for cylinder connection Optional connections Union nut G 5/8 Union nut G 3/4 Union nut 1,03” - 14 Union nut 1 ¼” USA yoke Optional accessories Manometer 0-16 bar, NG 63 with or without Min contact output Residual pressure control 2 bar Liquid trap, heating 230 V, cable with Euro plug Liquid trap, heating 115 V, cable with USA plug Vacuum regulator for serial installation Testing agents for tightness check • • • • • • • • • • • • • • • • • • 203.8 235.8 339.4 213.8 187.8 60.6 63 146 31.4 C 111-202 with manometer C 111-202 with liquid trap 90 75 25 40 6 190 165 400 165 6 105 130 Measurements in mm Single dosing regulator C 113-310/390 Capacity 2-40 g/h 5 - 100 g/h 10 - 250 g/h 25 - 500 g/h 50 - 1000 g/h 100 - 2000 g/h 150 - 3000 g/h 400 - 4000 g/h For operation with vacuum regulator 111-202 With compensation regulator and measuring device 10 m of vacuum line (PE hose 8/11) Fixing material included Dosing regulator C 113-390 with electric servomotor Synchronous motor with limit switches, IP 55 enclosure Actuating time (0-100%): 109 s at 50 Hz, 87 s at 60 Hz Power consumption: 3 VA Standard: mains voltage of servomotor 230 V (50/60 Hz) Option: mains voltage 115 V - please indicate separately Option : different measuring range (please see tabel below) with servomotor with 4-20 mA input for proption control, manual/automatic switch, trimmer for zero point/limit value, keys for manual control open/close • • • • • • • • • • • C 113-310 C 113-310 C117/GS 146 dosing system Vacuum regulator GS 146-010 Connection Capacity union nut 1” max. 10 kg/h With inlet valve and safety overpressure valve Overpressure connection for PE hose 8/11 Optional connection Union nut 1” Union nut G 5/8 Union nut G ¾ Union nut 1,03”-14 Union nut 1 ¼ USA yoke Optional accessories Plate for wall mounting, incl. fi xing material Manometer 0-16 bar, NG 63 Manometer 0-16 bar, NG 63, with Min contact output Liquid trap, heating 230 V, cable with Euro plug Liquid trap, heating 115 V, cable with USA plug Different vacuum connection for the dosing unit - optional Connection for PE hose 10/14 Connection for PE hose 12/16 Connection for PVC pipe 12/16 Connection for PVC pipe 15/20 • • • • • • • • • • • • • • • • • • This systems consists of Vacuum regulator GS 146-010 Single dosing regulator C 117-110 or 190 Dosing regulator C 117-110 Capacity 0,5 - 10 g/h 25 - 500 g/h 50 - 1000 g/h 100 - 2000 g/h 200 - 4000 g/h 300 - 6000 g/h 400 - 8000 g/h For the operation with vacuum regulator 146-.. Mounted on a plate for wall mounting With manual rate valve and measuring device Vacuum connection for PE hose or PVC pipe • • • • • • Dosing regulator C 117-190 Capacity 0,5 - 10 g/h Synchronous motor with limit switches, enclosure IP 55 Actuating time (0-100%): 108 s at 50 Hz, 87 s at 60 Hz Power consumption: 3 VA Standard: mains voltage servomotor 230 V (50/60 Hz) Options: mains voltage 115 V please indicate separately Option: different measuring range with servomotor 4-20 mA input for proportional control, manual/automatic switch, trimmer for zero point/limit value, keys for manual open/close • • • • • • 105 Ø 6 130 375 400 12.5 Dosing regulator C 117-110 575 600 Ø 6 145 170 Dosing regulator 117-190 with servomotor 2 Cl 20 C 0.932 bar abs ALLDOS from vacuum regulator du rÈgulateur de dÈpression vom Vakuumregler vers hydro-ejecteur zum Injektor to injector ̄9 360 400 Ø 6 610 650 A B 59 75 177 PE 10/14 160 200 86 173 Ø 9 177 143 Ø172 236 GS 146-010 Dosing regulator C 117-390 Measurements in mm 9 | GRUNDFOS ALLDOS | DISINFECTION GS 140 Series Vacuum regulator GS 146 and 148 Technical data for line installation, with integrated safety valve, with grooved fl ange 1” DN 25 (G1”), without liquid trap Chlorine gas Ammonia Sulphur dioxide Flow rate Vacuum connec- tion Order No. Flow rate Vacuum connec- tion Order No. Flow rate Vacuum connec- tion Type No. max. 40 kg/h PVC pipe 20/25 147-040 max. 20 kg/h PVC pipe 20/25 147-020N max. 38 kg/h PVC pipe 20/25 147-038S max. 70 kg/h PVC pipe 40/50 148-070 max. 35 kg/h PVC pipe 40/50 148-035N max. 65 kg/h PVC pipe 40/50 148-065S max. 120 kg/h PVC pipe 40/50 148-120 max. 60 kg/h PVC pipe 40/50 148-060N max. 115 kg/h PVC pipe 40/50 148-115S max. 200 kg/h PVC pipe 40/50 148-200 max. 100 kg/h PVC pipe 40/50 148-100N max. 190 kg/h PVC pipe 40/50 148-190 S Manometer for Cl 2 , 0-16 bar, NG 63, optionally with MIN contact (N.O./N.C.) without manometer, optionally prepared for pressure sensor Testing agents bottle with ammonia for tightness check (Cl 2 , SO 2 ) sulphur strips for tightness check (NH 3 ) System types Vacuum dosing system with rate valve Gas fl owmeter according to fl oater principle Vacuum meter NG 100 mm Manual adjustment of the dosing fl ow Differential pressure regulator Floor mounting unit, covered • • • • • • • • • • 209 52 Ø 175 128 170.5 105.5 DN 25 20/25 206 125 40/50 Ø 50 245 245 6.6 170 170 DN 25 6/8 GS 147 GS 148 GS 141-145 for wall mounting GS 141-145 with foot for fl oor mounting This systems consists of Vacuum regulator GS 146, 147 or 148 Dosing regulator GS 141, 143 or 145 Additional accessories • • • Measurements in mm 610 390 450 50 DN 40=730 1810 1000 DN 20=760 1000 Dosing regulator GS 141/143/145 Chlorine gas (Cl 2 ) Dosing capacity Vacuum connections Type No. 10 - 200 g/h PE hose 10/14 141 - 010 25 - 500 g/h 50 - 1000 g/h 100 - 2000 g/h 200 - 4000 g/h 400 - 8000 g/h 0,5 - 10 kg/h 1 - 20 kg/h PVC pipe 20/25 143 - 040 2 - 40 kg/h 3,5 - 70 kg/h PVC pipe 40/50 145 - 200 6 - 120 kg/h 10 - 200 kg/h Gas dosing system GS 141-145 Optional servomotor synchronous motor 3VA, IP 55, actuating time 0-100%: 90s at 50 Hz, 75 s at 60 Hz, installed on the rate valve 230 V (50/60 Hz), input/output 4-20 mA 115 V (50/60 Hz), input/output 4-20 mA Vacuum meter for injector vacuum NG 100 with 2 limit contact outputs Dosing system without vacuum meter Pressure sensors For injector vacuum For operating vacuum 2 pressure sensors (for injector and operating vacuum), signal evaluation via external PLC, required control voltage 24 V Enclosure versions Floor mounting unit with hood, open foot wall mounting unit with hood Optional vacuum connections (only GS 141) for PE hose 8/11, PE hose 12/16, PE hose ½”, PVC pipe 12/16, PVC pipe 15/20 • • • • • • • • • Chlorine gas disinfection systems ensure constant quality of your swimming pool water. 11 | GRUNDFOS ALLDOS | DISINFECTION 240.5 73 89 100 186 149.2 54 95.25 220.5 67 Ø 6.5 262 D2 D1 H D1 L Accessories Vacuum change-over device U 189 For combining 2 vacuum regulators with dosing regulators, vacuum connection PE hose 8/11 up to 4 kg/h, 10/14 up to 10 kg/h. Option Additionally with 2 Reed contacts for remote transmission of the empty signal, max. 50 V/1 A/50 W Accessories empty signal Description Order No. Display unit for empty signal, 115 V 332-2012 Display unit for empty signal, 230 V 332-2015 Wall mounting enclosure for display unit 300-210 • Vacuum change-over device U 189-010 Change-over device U 185-1 275 75 383.5 160 867 124 1170 475 110 475 110 493 396 340 Technical data Nominal pressure 16 bar Testing pressure 23 bar Connection inlet groove fl ange DN 25 (G1”)/PN 16, to DIN 2527/2512 Connection outlet tongue fl ange DN 25 (G1”)/PN 16, to DIN 2527/2512 Material valve body and fl anges: steel valve balls: stainless steel gaskets: PTFE, glass- fi ber reinforced lines: seamless drawn steel tube to DIN 2448 Protection IP 65 Actuating time 0- 100% 11 sec. at 50 Hz 9 sec. at 60 Hz Outputs 3 potential-free outputs; max. charge: 250 V AC, 10 A / 250 V DC, 1 A Power consumption 0,1 kW Weight 185-1: approx. 20 kg 185-2: approx. 30 kg Admiss. ambient temperature 0 to + 40 ̊ C (Cl 2 + NH 2 ) + 10 to + 40 ̊ C (SO 2 ) Change-over device U 186-120 40 145 173 86 43 68 217 Technical data Connection PVC tube 32/40 Maximum fl ow up to 120 kg/h for Cl 2 up to 60 kg/h for NH 3 up to 115 kg/h for SO 2 Servomotor protection: IP 65 actuating time 0 - 100%: 4 seconds adm. ambient temperature: 0 to +40 ̊ C adm. storage temperature: -10 to +50 ̊ C weight: 2 kg Control panel protection: IP 54 weight: 8,5 kg Connections PVC tube 32/40 PVC tube 40/50, extensions PVC tube 20/25, reductions Mains voltage control panel 115 V or 230 V (50/60 Hz) Fastening material for wall mounting Labelling of the control panel German, English, French or Spanish • • • • • • Vacuum change-over device U 185-1 Vacuum change-over device U 185-2 Measurements in mm Chlorine header line 542 Lacquered steel header line acc. to DIN 2441, fl exible copper lines and connection valves Connection threads 1” (standard “cylinder”) G 3/4” G 5/8” 1,03”-14 M 26x3 1 ¼” (standard “drums”) for closed yoke (USA, 1,03”-14) for open yoke (France, M 26x3) 15/16”-8RH For cylinders No. of cylin- ders Part No. 111 without liquid trap 111 with liquid trap 2 542-622 542-632 3 542-623 542-633 4 542-624 542-634 5 542-625 542-635 6 542-626 542-636 For drums 500 1000 1000 500 500 1000 500 3000 2000 G 1": L=160 G ": L=130 ½ L No. of drums Collector pipe G ½” Collector pipe G 1” Cl 2 NH 3 + SO 2 Cl 2 1 542-1 542-701 - 2 542-2 542-702 542-32 3 542-3 542-703 542-33 4 542-4 542-704 542-34 5 542-5 542-705 542-35 6 542-6 542-706 542-36 7 542-7 542-707 542-37 8 542-8 542-708 542-38 • • • • • • • • • 350 350 1” C B Header line 542 for cylinders H 162 H ~35 D L 2 L 1 T 2 T 1 Measurements in mm Pressure reducing valve 544 Technical data Nomin. pressure 16 bar Backpressure adjustable at 2-3 bar (Cl 2 ); at 3-4 bar (NH 3 ) Max. fl ow/ Medium Nominal diameter Connec- tions Servo- motor Order No. 40 kg/h Cl 2 DN 15 G ½” - 544-101 20 kg/h NH 3 DN 15 G ½” - 544-1017 200 kg/h Cl 2 DN 25 G 1” - 544-102 100 kg/h NH 3 DN 25 G 1” - 544-1027 40 kg/h Cl 2 DN 15 G ½” x 544-210 20 kg/h NH 3 DN 15 G ½” x 544-2107 200 kg/h Cl 2 DN 25 G 1” x 544-220 100 kg/h NH 3 DN 25 G 1 “ x 544-2207 Header line 542 for drums Accessories for pressure reducing valves Description Order No. Manometer 0 to 16 bar, G ¼” (for Cl 2 ) 541-010 Manometer 0 to 16 bar, G ¼” (for NH 3 ) 541-0107 Wall mounting bracket, steel 539-011 Connection set for copper pipe 6/8 (G ½” Cl 2 ) 529-11 Connection set for st. steel pipe 6/8 (G ½” NH 3 ) 529-1017 Pair of threaded fl anges (connection fl ange), groove and tongue, DN 15 529-112 Pair of threaded fl anges (counter fl ange), groove and tongue, DN 15 529-12 Pair of threaded fl anges (connection fl ange), groove and tongue, DN 25 529-113 Pair of threaded fl anges (counter fl ange), groove and tongue, DN 25 529-14 Pressure reducing valves 544 13 | GRUNDFOS ALLDOS | DISINFECTION L l D R Injection unit 522-242/-252 Injection units 522-242/-252 Material / Shut-off valve Connection chlorine solu- tion line Installation connection Order No. PVC / ball valve PVC pipe 20/25 G 1” 522-232 PVC pipe 25/32 G 1 ¼” 522-242 PVC pip 32/40 G 2 522-252 steel / diaphragm valve fl ange DN 25 G 1 ½” 522-302 fl ange DN 32 G 1 ½” 522-312 fl ange DN 50 fl ange DN 80 522-264 fl ange DN 65 fl ange DN 100 522-274 fl ange DN 80 fl ange DN 125 522-254 fl ange DN 100 fl ange DN 150 522-294 fl ange DN 125 fl ange DN 200 522-284 A d D Injector 3/4” 545-1000-2 / 545-2000-2 / 545-4000-2 Injector 1” 545-1000-3 / 545-2000-3 / 545-4000-3 Injectors for C 111/C 113 With non-return diaphragm FEP diaphragm PTFE piston PFFE coated spring Water connections for PVC pipe 20/25 Vacuum connection for PE hose 8/11 Technical data / Order data Max. capacity (g/h) Water fl ow (l/h) Adm. press. (bar) Back- press. (bar) Order No. Cl 2 500 300-700 2-16 0-7 545-0500-1 1000 550-1350 2-16 0-7 545-1000-1 2000 850-2220 2-16 0-7 545-2000-1 4000 1200-3300 2-16 0-7 545-4000-1 • • • • • • Measurements in mm Chlorine gas absorption cylinder 524-311 PVC, connection for PE tube 8/11, 5l content, fi lled with 4 kg absorb- ent, absorption capacity 450 g Cl 2 , including fi xing accessories The re fi lling granulate has the order no. 353-225. Technical data / Order data Max. capacity (g/h) Water quantity (l/h) Adm. pressure (bar) Backpressure (bar) Part Number Measurements d D A Water connections ¾” hose / ¾” NPT, vacuum connection 8/11 500 550-1350 2-16 0-7 545-1000-2 ¾” hose ¾” NPT 400 1000 850-2200 2-16 0-7 545-2000-2 Water connections 1” hose / 1” NPT, vacuum connection 8/11 500 550-1350 2-16 0-7 545-1000-3 1” hose 1” NPT 430 1000 850-2200 2-16 0-7 545-2000-3 2000 1350-3300 2,5-16 0-7 545-4000-3 Water connections 1 ¼” hose / 1 ¼” NPT, vacuum connection 8/11 3000 2500-4300 4-15 0,5-6,5 545-3030 1 ¼” hose 1 ¼” NPT 400 4000 3400-4700 4-8 0,5-3 545-4030 4000 3600-4300 9-15 3-6,5 545-3030 6000 4600-6000 9-15 3-6,5 545-4030 6000 3400-4500 4-8 0,5-3 545-6030 8000 4700-6000 9-15 3-6,5 545-6030 8000 4200-5800 4-8 0,5-3 545-8030 10.000 6000-8000 9-15 3-6,5 545-8030 10.000 5200-7200 4-8 0,5-3 545-10030 Injectors for GS Systems Technical data / Order data for Cl 2 max. operating pressure: 6 bar injectors for NH 3 and SO 2 on request Dosing capacity Cl 2 Counter pressure bar Length L (mm) Height H (mm) Connection motive water D1 Vacuum connec- tion D2 Connection chlo- rine solution D1 Order No. 10 kg/h 0,5-3 400 155 PVC pipe 25/32 PE hose 10/14 PVC pipe 25/32 545-0518 10 kg/h 0,5-3 400 155 hose NPT 1 ¼” PE hose ½“ hose NPT 1 ¼” 545-1519 10 kg/h 3-7 400 155 PVC pipe 25/32 PE hose 10/14 PVC pipe 25/32 545-3518 10 kg/h 3-7 400 155 hose NPT 1 ¼” PE hose ½” hose NPT 1 ¼” 545-4519 20 kg/h 0,5-3 480 190 PVC pipe 32/40 PVC pipe 20/25 PVC pipe 32/40 545-0615 20 kg/h 3-7 480 190 PVC pipe 32/40 PVC pipe 20/25 PVC pipe 32/40 545-3615 40 kg/h 0,5-3 710 310 PVC pipe 50/63 PVC pipe 20/25 PVC pipe 50/63 545-0715 40 kg/h 3-7 710 310 PVC pipe 50/63 PVC pipe 20/25 PVC pipe 50/63 545-3715 70 kg/h 0,5-3 650 325 PVC pipe 65/75 PVC pipe 40/50 PVC pipe 65/75 545-2816 70 kg/h 3-7 650 325 PVC pipe 65/75 PVC pipe 40/50 PVC pipe 65/75 545-5816 120 kg/h 0,5-3 720 325 PVC pipe 80/90 PVC pipe 40/50 PVC pipe 80/90 545-2916 120 kg/h 3-7 720 325 PVC pipe 80/90 PVC pipe 40/50 PVC pipe 80/90 545-5916 200 kg/h 0,5-3 825 370 PVC pipe 90/110 PVC pipe 40/50 PVC pipe 90/110 545-2016 200 kg/h 3-7 825 370 PVC pipe 90/110 PVC pipe 40/50 PVC pipe 90/110 545-5016 Injectors for C 117/GS 146 Variant: different vacuum connection Connection for PE hose 10/14 Connection for PE hose 12/16 Connection for PVC pipe 12/16 Connection for PVC pipe 15/20 • • • • Injector 1 ¼” 545-3030 / 545-4030 A d D DN 20 275 237 15 | GRUNDFOS ALLDOS | DISINFECTION Combined liquid chlorine trap and chlorine gas fi lter LiquFilt 524 steel vessel fi lled with chlorine- proof rock-wool heater strip Separates the liquid chlorine parts from the chlorine gas fl ow and cleans the gas from impurities • 290 490 ~ 190 130 Drum support Technical data Max. fl ow 200 kg/h Cl 2 (gaseous) Nominal pressure 16 bar Test pressure 23 bar Material high-grade seamless steel, Rockwool gasket material asbestos-free Input groove fl ange DN 25 (G 1”), DIN 2527/2512 Output tongue fl ange DN 25 (G 1”), DIN 2527/2512 Weight 22 kg Order data Description Type No. LiquFilt trap and fi lter, heater strip 115 V (50/60 Hz) 524-205 Order data Drum support set of two units for storate of one drum Type No. material: mounting plate: steel, laquered rollers, axles: steel, nickel-plated 505-632 drum size: min. 0.7 m, max. 1.06 m load: max. 2000 kg weight: 2 x 23 kg accessories: fastening screws, heavy-load dowels Chlorine cylinder balance Type No. 1 cylinder Type No. 2 cylinders without empty indication 505-624 505-625 with Reed contact for empty indica- tion 505-624-2 505-625-2 without output signal 4-20 mA 505-624-4 505-625-4 650 110 600 400 min. 110 10 108 M16 Ø 96 Ø 24 Drum support 505-632 Neutralisation Plant Being responsible is our foundation. We know that we have a responsibilty towards the people who are Grundfos, towards the innovation soul of Grundfos as well as towards the sur- rounding world. Whatever we do, we make sure that we have a firm and sustainable basis for doing it. Thinking ahead makes the innovations possible. We encourage a certain Grundfos way of thinking which is founded upon the belief that everyone must contribute by using his or her judgement and foresight. We are look- ing for commitment and ideas in everything we do in order to make the best solutions. We think - and we act. Innovation is the essence. It is the innovations that make Grundfos unique. We stand out because of our ability to con- stantly create new solutions to the ever-changing demands of the pump business. We meet every challenge and we are never afraid of taking the initiative - remainin gtrue to our ideals calls for renewal. Innovation is the soul of Grundfos. Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence www.grundfos.com