SDS REPORT Report No.: UTLR25083838-2 Page 1 of 19 Report Date: Aug.19,2025 ———————————————————————————————————————————————————————————— Except for full text reproduction, part of the report should not be copied without the written approval of this laboratory. Our report includes all of the tests requested by client and the results thereof based upon the information that you provided to us.The results in this report are not indicative of the quality or characteristics of the lot from which a test sample was taken unless specifically and expressly noted. Dongguan Universal Testing Technology Co., Ltd 3rd Floor, HuiHai Building, No.631 Yinlang South Road, Dalang Town, Dongguan City, Guangdong province, China. Post Code: 523785 Website :http://www.utl-lab.cn Tel : +86 400-0683-789 E-mail : utl@utl-lab.cn Hotline : +86 13602386325 Applicant : SHANTOU CITY CHENGHAI DISTRICT XINGJIA TOYS INDUSTRIAL CO.,LTD Address : NO.31-1 ZHENXING MIDDLE ROAD,XINLIAO VILLAGE,LIANXIA TOWN,CHENGHAI DISTRICT,SHANTOU CITY,GUANGDONG PROVINCE,CHINA Sample Information : Below sample and sample information are provided by client Sample Name : WATER PAINTS Trade Name : Wwzzey Sample Code : XJ558 、 XJ559 、 XJ560 、 XJ800 、 XJ801 、 XJ802 、 XJ803 、 XJ804 、 XJ805 、 XJ806 、 XJ807 、 XJ808 、 XJ809 、 XJ810 、 XJ811 、 XJ812 、 XJ813 、 XJ814 、 XJ815 、 XJ816 、 XJ817 、 XJ818 、 XJ819 、 XJ820 、 XJ821 、 XJ822 、 XJ823 、 XJ824 、 XJ825 、 XJ826 、 XJ827 、 XJ828 、 XJ829 、 XJ830 、 XJ831 、 XJ832 、 XJ833 、 XJ834 、 XJ835 、 XJ836 、 XJ837 、 XJ838 、 XJ839 、 XJ840 、 XJ841 、 XJ842 、 XJ843 、 XJ844 、 XJ845 、 XJ846 、 XJ847 、 XJ848 、 XJ849 、 XJ850 、 XJ851 、 XJ852 、 XJ853 、 XJ854 、 XJ855 、 XJ856 、 XJ857 、 XJ858 、 XJ859 、 XJ860 、 XJ861 、 XJ862 、 XJ863 、 XJ864 、 XJ865 、 XJ866 、 XJ867 、 XJ868 、 XJ869 、 XJ870 、 XJ871 、 XJ872 、 XJ873 、 XJ874 、 XJ875 、 XJ876 、 XJ877 Prepared Date : Aug.14,2025 to Aug.19,2025 RESULT SUMMARY: TEST REQUESTED CONCLUSION(S) Safety Data Sheet(SDS) See next pages Authorized Signatory Title: Lab Manager For and on behalf of Dongguan Universal Testing Technology Co., Ltd. SDS REPORT Report No.: UTLR25083838-2 Page 2 of 19 Report Date: Aug.19,2025 ———————————————————————————————————————————————————————————— Except for full text reproduction, part of the report should not be copied without the written approval of this laboratory. Our report includes all of the tests requested by client and the results thereof based upon the information that you provided to us.The results in this report are not indicative of the quality or characteristics of the lot from which a test sample was taken unless specifically and expressly noted. Dongguan Universal Testing Technology Co., Ltd 3rd Floor, HuiHai Building, No.631 Yinlang South Road, Dalang Town, Dongguan City, Guangdong province, China. Post Code: 523785 Website :http://www.utl-lab.cn Tel : +86 400-0683-789 E-mail : utl@utl-lab.cn Hotline : +86 13602386325 Section 1 - Chemical Product and Company Identification Sample Name : WATER PAINTS Trade Name : Wwzzey Sample Code : XJ558 、 XJ559 、 XJ560 、 XJ800 、 XJ801 、 XJ802 、 XJ803 、 XJ804 、 XJ805 、 XJ806 、 XJ807 、 XJ808 、 XJ809 、 XJ810 、 XJ811 、 XJ812 、 XJ813 、 XJ814 、 XJ815 、 XJ816 、 XJ817 、 XJ818 、 XJ819 、 XJ820 、 XJ821 、 XJ822 、 XJ823 、 XJ824 、 XJ825 、 XJ826 、 XJ827 、 XJ828 、 XJ829 、 XJ830 、 XJ831 、 XJ832 、 XJ833 、 XJ834 、 XJ835 、 XJ836 、 XJ837 、 XJ838 、 XJ839 、 XJ840 、 XJ841 、 XJ842 、 XJ843 、 XJ844 、 XJ845 、 XJ846 、 XJ847 、 XJ848 、 XJ849 、 XJ850 、 XJ851 、 XJ852 、 XJ853 、 XJ854 、 XJ855 、 XJ856 、 XJ857 、 XJ858 、 XJ859 、 XJ860 、 XJ861 、 XJ862 、 XJ863 、 XJ864 、 XJ865 、 XJ866 、 XJ867 、 XJ868 、 XJ869 、 XJ870 、 XJ871 、 XJ872 、 XJ873 、 XJ874 、 XJ875 、 XJ876 、 XJ877 Section 2 - Hazards Identification 2.1Classification of the substance or mixture In accordance with OSHA Hazard Communication Standard (29 CFR 1910.1200). Skin corrosion/irritation (Category 3), H316 Short-term (acute) aquatic hazard (Category 3), H402 For the full text of the H-Statements mentioned in this Section, see Section 16. Acute toxicity, Oral (Category 4), H302 Serious eye damage/eye irritation (Category 1), H318 Specific target organ toxicity - single exposure (Category 3), respiratory tract irritation, H335 Acute toxicity, Oral (Category 5), H303 Skin corrosion/irritation (Category 2), H315 Long-term (chronic) aquatic hazard (Category 3), H412 2.2Label elements according to OSHA Hazard Communication Standard (29 CFR 1910.1200). Hazard pictograms Signal Word : Danger Warning SDS REPORT Report No.: UTLR25083838-2 Page 3 of 19 Report Date: Aug.19,2025 ———————————————————————————————————————————————————————————— Except for full text reproduction, part of the report should not be copied without the written approval of this laboratory. Our report includes all of the tests requested by client and the results thereof based upon the information that you provided to us.The results in this report are not indicative of the quality or characteristics of the lot from which a test sample was taken unless specifically and expressly noted. Dongguan Universal Testing Technology Co., Ltd 3rd Floor, HuiHai Building, No.631 Yinlang South Road, Dalang Town, Dongguan City, Guangdong province, China. Post Code: 523785 Website :http://www.utl-lab.cn Tel : +86 400-0683-789 E-mail : utl@utl-lab.cn Hotline : +86 13602386325 2.3 Physical and chemical hazards Referring to current information, no physical or chemical hazard. 2.4 Health hazards Hazard Statements: H316 Causes mild skin irritation. H402 Harmful to aquatic life. H302 Harmful if swallowed. H318 Causes serious eye damage. H335 May cause respiratory irritation. H303 May be harmful if swallowed. H315 Causes skin irritation. H318 Causes serious eye damage. H412 Harmful to aquatic life with long lasting effects. Precautionary Statements : Prevention: P273 Avoid release to the environment. Response P261 Avoid breathing mist or vapors. P264 Wash skin thoroughly after handling. P270 Do not eat, drink or smoke when using this product. P271 Use only outdoors or in a well-ventilated area. P280 Wear eye protection/ face protection. Response: P332 + P313 If skin irritation occurs: Get medical advice/ attention. P301 + P312 + P330 IF SWALLOWED: Call a POISON CENTER/ doctor if you feel unwell. Rinse mouth. P304 + P340 + P312 IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/ doctor if you feel unwell. P305 + P351 + P338 + P310 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/ doctor. P302 + P352 IF ON SKIN: Wash with plenty of water. P312 Call a POISON CENTER/ doctor if you feel unwell. P362 + P364 Take off contaminated clothing and wash it before reuse. Storage: P403 + P233 Store in a well-ventilated place. Keep container tightly closed. P405 Store locked up. Disposal P501 Dispose of contents/ container to an approved waste disposal plant SDS REPORT Report No.: UTLR25083838-2 Page 4 of 19 Report Date: Aug.19,2025 ———————————————————————————————————————————————————————————— Except for full text reproduction, part of the report should not be copied without the written approval of this laboratory. Our report includes all of the tests requested by client and the results thereof based upon the information that you provided to us.The results in this report are not indicative of the quality or characteristics of the lot from which a test sample was taken unless specifically and expressly noted. Dongguan Universal Testing Technology Co., Ltd 3rd Floor, HuiHai Building, No.631 Yinlang South Road, Dalang Town, Dongguan City, Guangdong province, China. Post Code: 523785 Website :http://www.utl-lab.cn Tel : +86 400-0683-789 E-mail : utl@utl-lab.cn Hotline : +86 13602386325 Disposal: P501 Dispose of contents/ container to an approved waste disposal plant. 2.5 Environmental hazards H402 Harmful to aquatic life. H412 Harmful to aquatic life with long lasting effects. 2.6 Other hazards None known. Section 3 –Composition/Information on Ingredients Admixture Composition: Chemical Name Molecular Formula CAS No. EC No. Composition ( in% by weight ) Butyl methacrylate, methyl methacrylate, methacrylic acid polymer C17H28O6 28262-63-7 - 30 Water H2O 7732-18-5 231-791-2 58.5 Sodium polyacrylate C3H4O2 9003-04-7 999-999-2 2 2,2,4-Trimethyl-1,3- pentanediol monoisobutyrate C12H24O3 25265-77-4 246-771-9 2 Silicone oil C6H18OSi2 63148-62-9 613-156-5 0.5 2-Phenoxyethanol C8H10O2 122-99-6 204-589-7 0.5 Colorant - - - 2.5 2-Amino-2-methyl-1- propanol C4H11NO 124-68-5 204-709-8 4 SDS REPORT Report No.: UTLR25083838-2 Page 5 of 19 Report Date: Aug.19,2025 ———————————————————————————————————————————————————————————— Except for full text reproduction, part of the report should not be copied without the written approval of this laboratory. Our report includes all of the tests requested by client and the results thereof based upon the information that you provided to us.The results in this report are not indicative of the quality or characteristics of the lot from which a test sample was taken unless specifically and expressly noted. Dongguan Universal Testing Technology Co., Ltd 3rd Floor, HuiHai Building, No.631 Yinlang South Road, Dalang Town, Dongguan City, Guangdong province, China. Post Code: 523785 Website :http://www.utl-lab.cn Tel : +86 400-0683-789 E-mail : utl@utl-lab.cn Hotline : +86 13602386325 Section 4 - First Aid Measures General advice : Consult a physician. Show this safety data to the doctor in attendance. Move out of dangerous area. Skin touch: Remove contaminated clothes and rinse the skin with plenty of water and soap. Cool water should be used. Get medical aid if necessary Eyes touch: Lifting the upper and lower eyelids, flush the eyes with plenty of water for at least 15 minutes. Cool water should be used. Get medical aid if necessary Continue rinsing eyes during transport to hospital. Inhalation: Remove from exposure and move to fresh air immediately. Keep the respiratory tract smooth. Use oxygen if available. Get medical aid. Ingestion: Do not induce vomiting. Never give anything by mouth to an unconscious person. Rinse out mouth. Drink sufficient hot water. Get medical aid. Section 5 - Fire Fighting Measures Danger Fire-Fighting method & media: use extinguish ant such as dry sand, chemical dry powder, alcohol-resistant foam to put out the fire. Special protection equipment for firefighters: Firemen should wear proper protective equipment and positive pressure self-contained breathing apparatus. Special hazards arising from the substance or mixture: carbon oxides Special remarks on Fire Hazards: No further relevant information available. Section 6 –Accidental Release Measures 6.1 Personal precautions, protective equipment and emergency procedures Use personal protective equipment.Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas. For personal protection see section 8. 6.2 Environmental precautions Prevent further leakage or spillage if safe to do so. Do not let product enter drains. 6.3 Methods and materials for containment and cleaning up Contain spillage, and then collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13). Section 7 - Handling and Storage Handling: Avoid contact with eyes. Avoid inhalation of vapour or mist. Take measures to prevent the build up of electrostatic charge.Supply with sufficient partial air exhaust. It is advised that the staff wear respirator, wear work clothes, and wear gloves. Keep away from sources of ignition-No smoking. Use explosion-proof type ventilation system and device. Avoid contacting with oxidizer and strong acid. Equip with relevant types and quantities of extinguishment instruments and device for divulgence handling. Empty the container which may include harmful material. SDS REPORT Report No.: UTLR25083838-2 Page 6 of 19 Report Date: Aug.19,2025 ———————————————————————————————————————————————————————————— Except for full text reproduction, part of the report should not be copied without the written approval of this laboratory. Our report includes all of the tests requested by client and the results thereof based upon the information that you provided to us.The results in this report are not indicative of the quality or characteristics of the lot from which a test sample was taken unless specifically and expressly noted. Dongguan Universal Testing Technology Co., Ltd 3rd Floor, HuiHai Building, No.631 Yinlang South Road, Dalang Town, Dongguan City, Guangdong province, China. Post Code: 523785 Website :http://www.utl-lab.cn Tel : +86 400-0683-789 E-mail : utl@utl-lab.cn Hotline : +86 13602386325 Storage: Keep container tightly closed in a dry and well-ventilated place.Store in cool place. Hygroscopic. Away from fire, heat source,direct sunlight. With the oxidant and acid stored separately, avoid mixing reservoir. Equipped with the appropriate variety and quantity of fire equipment. Storage areas should be equipped with emergency treatment equipment for leakage and suitable housing materials. Section 8 - Exposure Controls, Personal Protection 8.1 Control parameters Ingredients with workplace control parameters Contains no substances with occupational exposure limit values. 8.2 Exposure controls Personal protective equipment Respiratory Protection: Where risk assessment shows air-purifying respirators are appropriate use a fullface particle respirator type N100 (US) or type P3 (EN 143) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU). Recommended Filter type: Filter A (acc. to DIN 3181) for vapours of organic compounds,Filter type ABEK Eyes Protection: Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses Skin protection This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de). Full contact Material: Nitrile rubber Minimum layer thickness: 0.11 mm Break through time: 480 min Material tested:KCL 741 Dermatril® L Splash contact Material: Nitrile rubber Minimum layer thickness: 0.11 mm Break through time: 480 min Material tested:KCL 741 Dermatril® L Full contact Material: Chloroprene SDS REPORT Report No.: UTLR25083838-2 Page 7 of 19 Report Date: Aug.19,2025 ———————————————————————————————————————————————————————————— Except for full text reproduction, part of the report should not be copied without the written approval of this laboratory. Our report includes all of the tests requested by client and the results thereof based upon the information that you provided to us.The results in this report are not indicative of the quality or characteristics of the lot from which a test sample was taken unless specifically and expressly noted. Dongguan Universal Testing Technology Co., Ltd 3rd Floor, HuiHai Building, No.631 Yinlang South Road, Dalang Town, Dongguan City, Guangdong province, China. Post Code: 523785 Website :http://www.utl-lab.cn Tel : +86 400-0683-789 E-mail : utl@utl-lab.cn Hotline : +86 13602386325 Minimum layer thickness: 0.65 mm Break through time: 480 min Material tested:KCL 720 Camapren® This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de). Splash contact Material: Latex gloves Minimum layer thickness: 0.6 mm Break through time: 30 min Material tested:Lapren® (KCL 706 / Aldrich Z677558, Size M) Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. Full contact Material: butyl-rubber Minimum layer thickness: 0.3 mm Break through time: 480 min Material tested:Butoject® (KCL 897 / Aldrich Z677647, Size M) Splash contact Material: Nitrile rubber Minimum layer thickness: 0.4 mm Break through time: 30 min Material tested:Camatril® (KCL 730 / Aldrich Z677442, Size M) data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374 If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the EC approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario. Body Protection: Flame retardant antistatic protective clothing. SDS REPORT Report No.: UTLR25083838-2 Page 8 of 19 Report Date: Aug.19,2025 ———————————————————————————————————————————————————————————— Except for full text reproduction, part of the report should not be copied without the written approval of this laboratory. Our report includes all of the tests requested by client and the results thereof based upon the information that you provided to us.The results in this report are not indicative of the quality or characteristics of the lot from which a test sample was taken unless specifically and expressly noted. Dongguan Universal Testing Technology Co., Ltd 3rd Floor, HuiHai Building, No.631 Yinlang South Road, Dalang Town, Dongguan City, Guangdong province, China. Post Code: 523785 Website :http://www.utl-lab.cn Tel : +86 400-0683-789 E-mail : utl@utl-lab.cn Hotline : +86 13602386325 Environmental exposure controls: Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Control measures must be made in accordance with community environmental protection legislation. Other Protections: No smoking, dining and drinking water in the workplace. Keep good habit of hygiene. Change clothes, wash your hands after work. Section 9 - Physical and Chemical Properties(information were provided by client) Appearance Form:No data available Color:No data available Odor: No data available Odor Threshold: No data available pH: No data available Meltingpoint/freezing point:No data available Initial boiling point and boiling range:No data available Flash point:No data available Evaporation rate:No data available Flammability (solid,gas):No data available Upper/lower flammability or explosive limits:No data available Vapor pressure:No data available Vapor density:No data available Relative density:No data available Water solubility:No data available Partition coefficient(n-octanol/water):No data available Autoignitiontemperature:No data available Decomposition temperature:No data available Viscosity Viscosity, kinematic:No data available Viscosity, dynamic:No data available Explosive properties:No data available Oxidizing properties:No data available Section 10 - Stability and Reactivity 10.1 Reactivity Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical. 10.2 Chemical stability The product is chemically stable under standard ambient conditions (room temperature) . 10.3 Possibility of hazardous reactions Violent reactions possible with: The generally known reaction partners of water. 10.4 Conditions to avoid Strong heating SDS REPORT Report No.: UTLR25083838-2 Page 9 of 19 Report Date: Aug.19,2025 ———————————————————————————————————————————————————————————— Except for full text reproduction, part of the report should not be copied without the written approval of this laboratory. Our report includes all of the tests requested by client and the results thereof based upon the information that you provided to us.The results in this report are not indicative of the quality or characteristics of the lot from which a test sample was taken unless specifically and expressly noted. Dongguan Universal Testing Technology Co., Ltd 3rd Floor, HuiHai Building, No.631 Yinlang South Road, Dalang Town, Dongguan City, Guangdong province, China. Post Code: 523785 Website :http://www.utl-lab.cn Tel : +86 400-0683-789 E-mail : utl@utl-lab.cn Hotline : +86 13602386325 10.5 Incompatible materials Strong oxidizing agents 10.6 Hazardous decomposition products In the event of fire: see section 5 Section 11 - Toxicological Information 11.1 Information on toxicological effects Acute toxicity Water: LD50 Oral - Rat - > 90,000 mg/kg Remarks: (RTECS) Inhalation: No data available Dermal: No data available Sodium polyacrylate: LD50 Oral - Rat - > 40,000 mg/kg Inhalation: No data available Dermal: No data available 2,2,4-Trimethyl-1,3-pentanediol monoisobutyrate: LD50 Oral - Rat - male - 6,500 mg/kg Remarks: (ECHA) Inhalation: No data available LD50 Dermal - Rabbit - male - > 15,200 mg/kg Remarks: (ECHA) 2-Phenoxyethanol: LD50 Oral - Rat - female - 1,840 mg/kg (OECD Test Guideline 401) LC50 Inhalation - Rat - male and female - 6 h - > 1,000 mg/m3 - aerosol (OECD Test Guideline 412) LD50 Dermal - Rat - female - > 2,000 mg/kg (OECD Test Guideline 402) 2-Amino-2-methyl-1-propanol: LD50 Oral - Rat - male - 2,900 mg/kg (OECD Test Guideline 401) Inhalation: No data available LD50 Dermal - Rabbit - male and female - > 2,000 mg/kg (OECD Test Guideline 402) SDS REPORT Report No.: UTLR25083838-2 Page 10 of 19 Report Date: Aug.19,2025 ———————————————————————————————————————————————————————————— Except for full text reproduction, part of the report should not be copied without the written approval of this laboratory. Our report includes all of the tests requested by client and the results thereof based upon the information that you provided to us.The results in this report are not indicative of the quality or characteristics of the lot from which a test sample was taken unless specifically and expressly noted. Dongguan Universal Testing Technology Co., Ltd 3rd Floor, HuiHai Building, No.631 Yinlang South Road, Dalang Town, Dongguan City, Guangdong province, China. Post Code: 523785 Website :http://www.utl-lab.cn Tel : +86 400-0683-789 E-mail : utl@utl-lab.cn Hotline : +86 13602386325 Skin corrosion/irritation 2,2,4-Trimethyl-1,3-pentanediol monoisobutyrate: Skin - Rabbit Result: Mild skin irritation - 4 h (Regulation (EC) No. 440/2008, Annex, B.4) 2-Phenoxyethanol: Skin - Rabbit Result: No skin irritation - 4 h (OECD Test Guideline 404) 2-Amino-2-methyl-1-propanol: Skin - Rabbit Result: Not corrosive (Regulation (EC) No. 440/2008, Annex, B.40) Remarks: (ECHA) Skin - Rabbit Result: Skin irritation Remarks: (ECHA) Serious eye damage/eye irritation 2,2,4-Trimethyl-1,3-pentanediol monoisobutyrate: Eyes - Rabbit Result: No eye irritation (OECD Test Guideline 405) 2-Phenoxyethanol: Eyes - Rabbit Result: Causes serious eye damage. - 15 Days (OECD Test Guideline 405) 2-Amino-2-methyl-1-propanol: Eyes - Rabbit Result: Severe eye irritation Remarks: (ECHA) Respiratory or skin sensitization 2,2,4-Trimethyl-1,3-pentanediol monoisobutyrate: Maximization Test - Guinea pig Result: negative (Regulation (EC) No. 440/2008, Annex, B.6) 2-Phenoxyethanol: Maximization Test - Guinea pig Result: negative (OECD Test Guideline 406) SDS REPORT Report No.: UTLR25083838-2 Page 11 of 19 Report Date: Aug.19,2025 ———————————————————————————————————————————————————————————— Except for full text reproduction, part of the report should not be copied without the written approval of this laboratory. Our report includes all of the tests requested by client and the results thereof based upon the information that you provided to us.The results in this report are not indicative of the quality or characteristics of the lot from which a test sample was taken unless specifically and expressly noted. Dongguan Universal Testing Technology Co., Ltd 3rd Floor, HuiHai Building, No.631 Yinlang South Road, Dalang Town, Dongguan City, Guangdong province, China. Post Code: 523785 Website :http://www.utl-lab.cn Tel : +86 400-0683-789 E-mail : utl@utl-lab.cn Hotline : +86 13602386325 2-Amino-2-methyl-1-propanol: Buehler Test - Guinea pig Result: negative (OECD Test Guideline 406) Germ cell mutagenicity 2,2,4-Trimethyl-1,3-pentanediol monoisobutyrate: Test Type: Ames test Test system: S. typhimurium Metabolic activation: with and without metabolic activation Method: OECD Test Guideline 471 Result: negative Test Type: In vivo micronucleus test Species: Mouse Cell type: Bone marrow Application Route: Oral Method: OECD Test Guideline 474 Result: negative 2-Phenoxyethanol: Test Type: Ames test Test system: Escherichia coli/Salmonella typhimurium Metabolic activation: with and without metabolic activation Method: OECD Test Guideline 471 Result: negative Test Type: In vitro mammalian cell gene mutation test Test system: Chinese hamster lung cells Metabolic activation: with and without metabolic activation Method: OECD Test Guideline 476 Result: Positive results were obtained in some in vitro tests. Test Type: Mutagenicity (mammal cell test): chromosome aberration. Test system: Chinese hamster lung cells Metabolic activation: with and without metabolic activation Method: OECD Test Guideline 473 Result: negative Test Type: Micronucleus test Species: Mouse Cell type: Red blood cells (erythrocytes) Application Route: Intraperitoneal Method: OECD Test Guideline 474 Result: negative SDS REPORT Report No.: UTLR25083838-2 Page 12 of 19 Report Date: Aug.19,2025 ———————————————————————————————————————————————————————————— Except for full text reproduction, part of the report should not be copied without the written approval of this laboratory. Our report includes all of the tests requested by client and the results thereof based upon the information that you provided to us.The results in this report are not indicative of the quality or characteristics of the lot from which a test sample was taken unless specifically and expressly noted. Dongguan Universal Testing Technology Co., Ltd 3rd Floor, HuiHai Building, No.631 Yinlang South Road, Dalang Town, Dongguan City, Guangdong province, China. Post Code: 523785 Website :http://www.utl-lab.cn Tel : +86 400-0683-789 E-mail : utl@utl-lab.cn Hotline : +86 13602386325 Test Type: unscheduled DNA synthesis assay Species: Rat Cell type: Liver cells Application Route: Oral Method: OECD Test Guideline 486 Result: negative Test Type: Chromosome aberration test Species: Rat Cell type: Bone marrow Application Route: Oral Result: negative Remarks: (ECHA) 2-Amino-2-methyl-1-propanol: Test Type: Ames test Test system: Escherichia coli/Salmonella typhimurium Metabolic activation: with and without metabolic activation Method: OECD Test Guideline 471 Result: negative Test Type: In vitro mammalian cell gene mutation test Test system: Mouse lymphoma test Metabolic activation: with and without metabolic activation Method: OECD Test Guideline 476 Result: negative Test Type: Micronucleus test Species: Mouse Cell type: Bone marrow Application Route: Intraperitoneal injection Method: OECD Test Guideline 474 Result: negative Carcinogenicity No data available Reproductive toxicity No data available SDS REPORT Report No.: UTLR25083838-2 Page 13 of 19 Report Date: Aug.19,2025 ———————————————————————————————————————————————————————————— Except for full text reproduction, part of the report should not be copied without the written approval of this laboratory. Our report includes all of the tests requested by client and the results thereof based upon the information that you provided to us.The results in this report are not indicative of the quality or characteristics of the lot from which a test sample was taken unless specifically and expressly noted. Dongguan Universal Testing Technology Co., Ltd 3rd Floor, HuiHai Building, No.631 Yinlang South Road, Dalang Town, Dongguan City, Guangdong province, China. Post Code: 523785 Website :http://www.utl-lab.cn Tel : +86 400-0683-789 E-mail : utl@utl-lab.cn Hotline : +86 13602386325 Specific target organ toxicity - single exposure 2-Phenoxyethanol: May cause respiratory irritation. - Respiratory Tract Remarks: Classified according to Regulation (EU) 1272/2008, Annex VI (Table 3.1/3.2) Specific target organ toxicity - repeated exposure No data available Aspiration hazard No data available 11.2 Additional Information Water: RTECS: ZC0110000 To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated. Sodium polyacrylate: RTECS: WD6826000 Gastrointestinal disturbance To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated. 2,2,4-Trimethyl-1,3-pentanediol monoisobutyrate: Repeated dose toxicity - Rat - male - Oral - 51 Days - NOAEL (No observed adverse effect level) - 1,000 mg/kg RTECS: UF6000000 To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated. Silicone oil: Assessment : The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher. RTECS: TQ2690000 To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated. Propertys which must be anticipated by analogy: 2-Phenoxyethanol: Repeated dose toxicity - Rat - male and female - Oral - 13 Weeks - NOAEL (No observed adverse effect level) - 369 mg/kg Repeated dose toxicity - Rabbit - male and female - Dermal - 13 Weeks - NOAEL (No observed adverse effect level) - 500 mg/kg - LOAEL (Lowest observed adverse effect level) - > 500 mg/kg To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated. SDS REPORT Report No.: UTLR25083838-2 Page 14 of 19 Report Date: Aug.19,2025 ———————————————————————————————————————————————————————————— Except for full text reproduction, part of the report should not be copied without the written approval of this laboratory. Our report includes all of the tests requested by client and the results thereof based upon the information that you provided to us.The results in this report are not indicative of the quality or characteristics of the lot from which a test sample was taken unless specifically and expressly noted. Dongguan Universal Testing Technology Co., Ltd 3rd Floor, HuiHai Building, No.631 Yinlang South Road, Dalang Town, Dongguan City, Guangdong province, China. Post Code: 523785 Website :http://www.utl-lab.cn Tel : +86 400-0683-789 E-mail : utl@utl-lab.cn Hotline : +86 13602386325 2-Amino-2-methyl-1-propanol: To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated. Section 12 - Ecological Information 12.1 Toxicity Sodium polyacrylate: Toxicity to fish static test LC50 - Pimephales promelas (fathead minnow) - 33 mg/l - 96 h (OECD Test Guideline 203) Toxicity to daphnia and other aquatic invertebrates static test EC50 - Daphnia magna (Water flea) - 147.8 mg/l - 48 h (OECD Test Guideline 202) Toxicity to algae static test ErC50 - Pseudokirchneriella subcapitata - 15 mg/l - 72 h (OECD Test Guideline 201) 2-Phenoxyethanol: Toxicity to fish static test LC50 - Leuciscus idus (Golden orfe) - > 220 - < 460 mg/l - 96 h (DIN 38412) Toxicity to daphnia and other aquatic invertebrates static test EC50 - Daphnia magna (Water flea) - > 500 mg/l - 48 h (OECD Test Guideline 202) Toxicity to algae static test ErC50 - Desmodesmus subspicatus (green algae) - 625 mg/l - 72 h (Regulation (EC) No. 440/2008, Annex, C.3) Toxicity to bacteria static test EC50 - activated sludge - > 1,000 mg/l - 30 min (OECD Test Guideline 209) Toxicity to fish(Chronic toxicity) flow-through test NOEC - Pimephales promelas (fathead minnow) - 24 mg/l - 34 d (OECD Test Guideline 210) Toxicity to daphnia and other aquatic invertebrates(Chronic toxicity) semi-static test NOEC - Daphnia magna (Water flea) - 9.43 mg/l - 21 d (OECD Test Guideline 211) 2-Amino-2-methyl-1-propanol: Toxicity to fish static test LC50 - Lepomis macrochirus (Bluegill sunfish) - 190 mg/l - 96 h (US-EPA) Toxicity to daphnia and other aquatic invertebrates static test LC50 - Daphnia magna (Water flea) - 193 mg/l - 48 h (US-EPA) Toxicity to algae static test EC50 - Desmodesmus subspicatus (green algae) - 402 mg/l - 72 h (OECD Test Guideline 201) Toxicity to bacteria static test EC50 - activated sludge - 342.9 mg/l - 3 h (OECD Test Guideline 209) 12.2 Persistence and degradability Sodium polyacrylate: Biodegradability aerobic - Exposure time 28 d Result: > 98 % - Readily biodegradable. (OECD Test Guideline 301B) SDS REPORT Report No.: UTLR25083838-2 Page 15 of 19 Report Date: Aug.19,2025 ———————————————————————————————————————————————————————————— Except for full text reproduction, part of the report should not be copied without the written approval of this laboratory. Our report includes all of the tests requested by client and the results thereof based upon the information that you provided to us.The results in this report are not indicative of the quality or characteristics of the lot from which a test sample was taken unless specifically and expressly noted. Dongguan Universal Testing Technology Co., Ltd 3rd Floor, HuiHai Building, No.631 Yinlang South Road, Dalang Town, Dongguan City, Guangdong province, China. Post Code: 523785 Website :http://www.utl-lab.cn Tel : +86 400-0683-789 E-mail : utl@utl-lab.cn Hotline : +86 13602386325 2-Phenoxyethanol: Biodegradability aerobic - Exposure time 3 d Result: 98 % - Readily biodegradable. (OECD Test Guideline 301A) Chemical Oxygen Demand (COD) 2.127 mg/g Remarks: (IUCLID) 2-Amino-2-methyl-1-propanol: Biodegradability aerobic - Exposure time 28 d Result: 89.3 % - Readily biodegradable. (OECD Test Guideline 301F) 12.3 Bioaccumulative potential No data available 12.4 Mobility in soil No data available 12.5 Results of PBT and vPvB assessment This substance/mixture contains no components considered to be either persistent,bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) atlevels of 0.1% or higher. 12.6 Other adverse effects No data available Section 13 - Disposal Considerations Product The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems. Contaminated packaging Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials. SDS REPORT Report No.: UTLR25083838-2 Page 16 of 19 Report Date: Aug.19,2025 ———————————————————————————————————————————————————————————— Except for full text reproduction, part of the report should not be copied without the written approval of this laboratory. Our report includes all of the tests requested by client and the results thereof based upon the information that you provided to us.The results in this report are not indicative of the quality or characteristics of the lot from which a test sample was taken unless specifically and expressly noted. Dongguan Universal Testing Technology Co., Ltd 3rd Floor, HuiHai Building, No.631 Yinlang South Road, Dalang Town, Dongguan City, Guangdong province, China. Post Code: 523785 Website :http://www.utl-lab.cn Tel : +86 400-0683-789 E-mail : utl@utl-lab.cn Hotline : +86 13602386325 Section 14 - Transport Information 14.1 UN number ADR/RID: - IMDG: - IATA-DGR: - 14.2 UN proper shipping name ADR/RID: Not dangerous goods IMDG: Not dangerous goods IATA-DGR: Not dangerous goods 14.3 Transport hazard class(es) ADR/RID: - IMDG: - IATA-DGR: - 14.4 Packaging group ADR/RID: - IMDG: - IATA-DGR: - 14.5 Environmental hazards ADR/RID: no IMDG Marine pollutant: no IATA-DGR: no 14.6 Special precautions for user Transport Attentions: Examine whether the package of the containers are integrate and tighten closed before transport. No divulgence, no collapse, no precipitation or no damage during the course of transportation. Don’t put the goods together with oxidizer, acid and so on. The transport vehicle and ship must be cleaned and sterilized otherwise it is not allowed to assemble articles. During transport, the vehicle should prevent exposure, rain and high temperature. For stopovers, the vehicle should be away from fire and heat sources. Don’t use device and tools which can easily produce spark for loading. When transported by sea, the assemble place should keep away from bedroom and kitchen, and isolated from the engine room, power and fire source. Under the condition of Road Transportation, the driver should drive in accordance with regulated route, don’t stop over in the residential area and congested area. No slipping up in rail road. According to the IMDG Code(inc Amdt 42-24) 2024 Edition, The sample is not regulated for transport of dangerous goods. According to the Air transport ICAO-TI and IATA-DGR 66 th , The sample is not regulated by IATA Dangerous Good Regulations 66 th edition. SDS REPORT Report No.: UTLR25083838-2 Page 17 of 19 Report Date: Aug.19,2025 ———————————————————————————————————————————————————————————— Except for full text reproduction, part of the report should not be copied without the written approval of this laboratory. Our report includes all of the tests requested by client and the results thereof based upon the information that you provided to us.The results in this report are not indicative of the quality or characteristics of the lot from which a test sample was taken unless specifically and expressly noted. Dongguan Universal Testing Technology Co., Ltd 3rd Floor, HuiHai Building, No.631 Yinlang South Road, Dalang Town, Dongguan City, Guangdong province, China. Post Code: 523785 Website :http://www.utl-lab.cn Tel : +86 400-0683-789 E-mail : utl@utl-lab.cn Hotline : +86 13602386325 Section 15 - Regulatory Information Regulatory Information: The resin system components listed in the hazardous waste substances list of country(HW13) 《 Dangerous Goods Regulation 》 《 Recommendations on the Transports of Dangerous Goods Model Regulations 》 《 International Maritime Dangerous Goods 》 (IMDG) 《 Technical Instructions for the Safe Transport of Dangerous Goods 》 《 Classification and code of dangerous goods 》 《 Occupational Safety and Health Act 》 (OSHA) 《 Toxic Substances Control Act 》 (TSCA) 《 Consumer Product Safety Act 》 (CPSA) 《 Federal Environmental Pollution Control Act 》 (FEPCA) 《 The Oil Pollution Act 》 (OPA) 《 Superfund Amendments and Reauthorization Act Title III(302/311/312/313) 》 (SARA) 《 Resource Conservation and Recovery Act 》 (RCRA) 《 Safety Drinking Water Act 》 《 California Pr