Grundfos Tubewell DC 2 SP SYSTEMS Comprising a stainless steel SP pump, a Grundfos-designed motor, and a dedicated electronic motor protection unit, Grundfos Tubewell DC panel - are designed to bring you efficient water supply in any size application. Grundfos Tubewell DC 2 Features 2 Features - Standard Protection Devices - Manual Motor Starters (MMS) circuit breaker for individual pump: > Short circuit protection > Thermal overload > Phase failure protection (during operation) *Up to 7.5kW only. MCCB used for 11kW and above & tubewell with MP204 - Dry run protection (suction tank level sensor) Monitoring Function of Grundfos MP204 - Phase voltage and current (True RMS) - Motor temperature via tempcon (Grundfos motor) - Motor temperature via PT100 (additional) - Power input and energy consumption (totalizer) with reset function - Phase sequence - Current unbalance - Operating hours and numbers of starting reset function - Starting and run capacitor value (single phase only) - Insulation resistance - Power factor - Harmonic distortion Protection Function of MP204 - Under/ over voltage - Overload - Dry-run protection (secondary) - High temperature - Missing phase - Phase sequence - Hi/ low power factor limits - Current unbalance - Low insulation limits Other Features of MP204 - Tripping code with 5 alarm logs - Learn function - Current or temperature readout - Trip delays - Power on delay - Auto restart with delay timer (selectable) - Tempcon, PT 100/1000 and PTC function - Service warning timer - Advance setting via R100 (sold separately) Benefits - One touch easy operation - User friendly and easy monitoring mimic diagram with indication light at the controller - Troubleshooting made easy with front indication lights at the controller card - Built in starting delay timer change over - Phase failure protection as standard - High quality components MP204 Grundfos Tubewell DC 2 3 Grundfos Tubewell DC Technical Data Grundfos Tubewell DC Selection of Tubewell Indoor/ Outdoor Control Panel MS 402 4" 0.37 4.0 SA-SPM2 Direct On-Line Starter MS 402 4" 0.55 5.8 SA-SPM2 Direct On-Line Starter MS 402 4" 0.75 7.5 SA-SPM2 Direct On-Line Starter MS 402 4" 1.1 7.3 SA-SPM3 Direct On-Line Starter MS 402 4" 1.5 10.2 SA-SPM3 Direct On-Line Starter MS 4000 4" 2.2 14.0 SA-SPM3 Direct On-Line Starter Full Load Current (Amps) Control Box for 3-wire motor Type of Control Panel Motor Type Size Power (kW) 1 x 230 V 3 x 415V MS 402 4" 0.37 1.4 MS 402 4" 0.55 2.2 MS 402 4" 0.75 2.3 MS 402 4" 1.1 3.4 MS 402 4" 1.5 4.2 MS 402 4" 2.2 5.5 MS 4000 4" 2.2 6.7 MS 4000 4" 3.0 8.5 MS 4000 4" 5.5 13.8 MS 6000 6" 5.5 13.8 MS 6000 6" 7.5 17.8 MS 6000 6" 9.2 21.8 MS 6000 6" 11.0 24.8 MS 6000 6" 13.0 30.0 MS 6000 6" 15.0 34.0 MS 6000 6" 18.5 42.5 MS 6000 6" 22.0 47.5 MS 6000 6" 26.0 57.0 MS 6000 6" 30.0 66.5 Auto Transformer Starter Auto Transformer Starter Auto Transformer Starter Auto Transformer Starter Auto Transformer Starter Auto Transformer Starter Auto Transformer Starter Auto Transformer Starter Auto Transformer Starter Auto Transformer Starter Auto Transformer Starter Auto Transformer Starter Direct On-Line Starter Direct On-Line Starter Direct On-Line Starter Direct On-Line Starter Type of Control Panel Direct On-Line Starter Direct On-Line Starter Direct On-Line Starter Motor Full Load Current (Amps) Type Size Power (kW) Example of Installation: Grundfos SP Pump Control Panel Start level Stop level (Dry run protection) Start level Stop level Common Grundfos Tubewell DC 2 Grundfos Tubewell DC Dimension Details Grundfos Tubewell DC Direct On-Line & Auto Transformer Starter Panel 0.35kW - 7.5kW 400 500 500 200 Auto Transformer Starter Panel 11kW - 22kW 250 500 800 600 Direct On Line 0.37kW - 2.2kW Starter Panel with MP 204 Autotrans 18.5kW - 22kW Starter Panel with MP 204 Autotrans 3kW - 15kW Starter Panel with MP 204 Panel Specifications > Standard rated voltage: 1ph/ 3ph, 380-415VAC, 50HZ. (Other voltage available upon request) > Enclosure type: IP54 > Enclosure material: 1.5mm thickness, MS epoxy coated, suitable for weatherproof as per Grundfos standard > Ambient temperature: +5 to 45 deg.Celsius. > Operating current: Depends on pump model > Motor starting: DOL : 0.37 kW to 2.2kW Autotrans: 3kW and above. *Please refer to Grundfos for other options e.g soft start, VSD etc. GRUNDFOS PUMPS SDN BHD (202527-A) 7, Jalan Peguam U1/25 Glenmarie Industrial Park 40150 Shah Alam, Selangor, Malaysia. Tel : +603-5569 2922 Fax : +603-5569 2866 E-mail: gfosmy1@grundfos.com Cert No.: KLR0402930 Branch Office Northen & East Coast 10, Ground Floor, Jalan Todak 4, Bandar Sunway, 13700 Seberang Jaya, Penang Tel : +604-818 3779 Fax : +604-818 3848 East Malaysia Lot 8, Lorong Industri Warisan 1, Taman Industri Warisan Indah, Mile 7, Old Tuaran Road 88450 Inanam, Kota Kinabalu, Sabah Tel : +6088-380 663/-383 663 Fax : +6088-383 621 GPM/WU/200901V1 *Dimension of starter panel above 22kW upon request