The Controlled Environment Cleaning Specialists CONTANMINATION CONTROL/ PARTICLE COUNT/ INDOOR AIR QUALTY KOLDLOK / AISLELOK / PLENAFORM HIGH AIRFLOW PANELS HOTLOK / PLENAFILL / EZIBLANK HOT & COLD AISLE CONTAINMENT SOLUTIONS AIRFLOW ANALYSIS / ENERGY STUDIES / POWER QUALITY MONITORING 2 ABOUT US AIRFLOW MANAGEMENT SERVICES Data Clean has been serving its clients with Airflow Management Services since 2002. In the beginning, the goal was implementation of the new hot aisle/cold aisle concept. Today, the goal is total isolation of the hot and cold sides of the equipment. Simple in theory, implementation of total isolation can be challenging; particularly in existing facilities. Data Clean has developed the expertise to successfully guide our clients to total isolation in data centers around the world. The Data Clean Airflow Management Service is your choice for low cost, high impact solutions. Measure conditions and capacities Model solution technology Design solution Model solution financials Implement and install Data Clean understands that the path to total isolation is as varied as individual data center facilities. Our services adjust to fit your needs. Proper airflow management reduces energy, frees resources and saves money. Cooling can be half of the total energy consumed in a data center Cold air is wasted if not properly managed Proper isolation is critical to achieve cooling efficiency Efficient Cooling Directs airflow through, not around IT equipment The Path to Total Isolation Prevents bypass airflow Eliminates hot air recirculating directly to IT equipment Reach Your Goals with Data Clean Eliminate Bypass Airflow • Raise Set Points • Lower PUE • Eliminate Hot Spots Support Higher Density Installations • Reduce Cost Equipment Rack Equipment Rack CRAC / CRAH The Path to Total Isolation Data Center Power Consumption IT LOAD OTHER COOLING 3 ABOUT US SETTING THE STANDARD IN CRITICAL ENVIRONMENT CLEANING Why Choose Data Clean? Insured • Trained • Tested Data Clean customers choose Data Clean because we do more and we do it better. Experience Known Worldwide Data Clean operates Full-service branches around the globe and maintains thousands of controlled environments worldwide – visit www.dataclean.com to locate a branch near you. Recommended Some of the most respected and trusted companies in the IT and communications industries use Data Clean to maintain their critical environments. Ask your Data Clean Account Manager for references. Insured & Secure Data Clean is fully insured and our service technicians wear uniforms and photo IDs for your protection. Technicians are subject to random drug and alcohol testing. Your Data is Worth Millions Why Risk It? A dirty environment creates the risk of equipment failure and downtime caused by contamination. Left unchecked, contaminates accumulate and can cause equipment overheating due to clogged filters and heatsinks, or even create direct short circuits.Data Clean understands your environment is unique and we will develop a custom maintenance program to ensure your facility operates as reliably and efficiently as possible. A well maintained facility yields many benefits: EQUIPMENT High Reliability Maximum Uptime FACILITIES Energy Efficient Professional Image PEOPLE Healthy Environment Improved Productivity Data Clean technicians are experts. They have the training, tools and experience required to safely and effectively clean a variety of datacom environments Highly Trained Technicians Data Clean technicians are thoroughly trained to work around the sensitive equipment in today’s state-of-the-art datacom environments. Flexible 24/7 Scheduling & Emergency Services Schedule your cleaning and maintenance services when it’s convenient for you and the needs of your business. 100% Satisfaction Guaranteed The Data Clean 100% Satisfaction Guarantee is our ongoing promise to you that we will do whatever it takes to make sure you are totally satisfied.. Data Centers Server Rooms Computer Rooms Telecom Facilities Video HeadEnds Electrical Rooms Construction Sites Non-Traditional Environments IDF/MDF Rooms 4 ABOUT US CRITICAL ENVIRONMENT CLEANING 1 3 2 5 4 1 2 3 4 5 Consulting and Specialty Services Data Clean offers specialty services to help clients reduce the risk of downtime: Facility Surveys Contaminant Identification & Evaluation Airborne Particle Counts Zinc Whisker Testing & Remediation Gaseous Contamination Testing & Remediation 5 ABOUT US 1 3 5 2 4 6 Ceiling plenum cleaning is especially important when the plenum is used for return air. Airborne particulate can settle on building structure and MEP systems. Building vibration and airflow changes can cause existing settled contaminants to become airborne and burden CRAC/ CRAH filters or contaminate equipment below. Cable trays, lighting, ductwork,and piping are all areas of your Data Center that are outof sight and often neglected. Not only do harmful dustparticles settle on the equipment in the room, but also accumulate on the overhead components. Building vibration and airflow changes can dislodge settled particulate. Floor surface cleaning removes ground-in contaminates which diminish the built-in conductivity of the floor surface.The dirtier the floor, the lower floor’s ability to dissipate potentially dangerous static electricity. Data Clean maintains all types of flooring, including: High Pressure Laminate (HPL) epoxy, vinyl, and carpet. During construction is exactly when an on-line environment requires additional cleaning to ensure reliable operation. Data Clean provides both Clean-Construction Cleaning and Final Clean Services. Underfloor plenum cleaning removes settled particulate to prevent it from becoming airborne and ultimately harming sensitive datacom equipment or activating smoke detectors. Whether it’s cleaning only the outside of equipment racks and cabinets or cleaning inside the actual IT equipment, Data Clean offers 5 different levels of equipment cleaning to meet your every need. Data Clean also cleans the environment and support equipment from the floor to the ceiling and everything in between. Ceiling Underfloor Equipment & Environmental Overhead Floors Construction 6 ABOUT US THE CONTROLLED ENVIRONMENT CLEANING SPECIALISTS Since 1979, we at Data Clean have been providing a high quality maintenance services for a variety of controlled environments, extending beyond cleanrooms to all other critical environments as well. CleanRooms Data Clean uses proven techniques to remove dirt, dust, and other contaminants from your cleanroom, from those visible to the eye, to more importantly, those that are not visible at all. Data Clean’s trained technicians use specialized cleaning solutions - time tested for use in clean rooms. Our HEPA or ULPA filtered vacuums are certified to 0.3 microns and 0.1 microns, respectively, and remove even the smallest of micro-particles from your facility. We are able to clean from floor to ceiling. No area is out of our reach. Before a Data Clean Technician is sent into the field he must successfully complete a comprehensive training program which covers specific cleaning techniques particular to your operational needs keeping in mind delicate electronic equipment. Through strict adherence to standard operating procedures, Data Clean cleaning technicians follow strict protocol, we thereby offering a service standard par excellence. All our workers have expert knowledge of a range of contamination methods and are equipped with the requisite skill set to meet all your critical environment cleaning needs. Whether your needs are construction cleaning or daily maintenance, Data Clean technicians can perform all aspects of clean room cleaning - from construction cleaning to daily maintenance. 7 ABOUT US HOW CLEAN DO YOU WANT YOUR CLEANROOM TO BE? Equipment Cleaning Portable Particle Counters Data Clean offers the following clean room cleaning services performed on a variable frequency. Service frequency ranges from a one-time event to daily maintenance. The scope of each service is adjusted based on the existing level of facility cleanliness and the target level of cleanliness. Cleanrooms: ISO 14644 - 1: Class 1 - Class 9 Fed. Std. 209E: Class 1 - Class 100,000 Whether your cleanroom is a small soft-wall enclosure or high standard of cleanliness must be maintained in order to maintain the process or product yield. Data Clean will collaborate with you with regard to your established cleaning practices and even go one step further, by working with you to enhance your cleaning protocols resulting in your improved productivity. Data Clean Cleaning technicians are experts at cleaning and removing harmful contaminates such as dirt, dust and residues from the exterior surfaces on your support equipments and all areas in the control room environments. Particle counters are required equipment for certifying and testing cleanrooms, data centres and other critical environments. These critical measurements to comply with ISO 14644-1 and various GMP regulations worldwide. 8 ABOUT US SELF-CONTAINED DATA CENTRE AIR PURIFIER Keep electronics safe from corrosive pollutants - while improving indoor air quality Capture harmful gases in your data centre The PureAir DC-1000 is a self-contained, moveable unit that recirculates the air in data centers. As the air passed through PureAir’s gas adsorbent media, harmful corrosive gases are captured and permanently bound. Purified air is sent out the top of the DC-1000 where it is used to cool servers without harming electrical components. Long-ranging, easy protection The DC-1000 has low energy consumption and noise, and installation is a snap in your existing server cabnets, plugging into standard electrical sockets. Each unit provides protection for up to 5000 square feet (approximately 500 M2). Airflow is variable, controllable up to 1000 cfm (1700 CMH), and differential pressure gauges indicate filter changes for easy maintenance. 9 ABOUT US MERV 7 (G4) Dust Prefilter 4 cubic feet (113 liters) of PureAir gas adsorbent media filled in low pressure holding frames MERV 14 (F8) Dust Final Filter Available with 110-230V and 50/60 V options Differential pressure gauges to indicate dust filter changes Low energy consumption - 0.7 kW Low noise Each unit provide protection for up to 5000 square feet (approx 500 M2) Variable control of airflow up to 1000 cfm (1700CMH) Low EMF brushless AC blower motor Features Unit Sizing Room Air Volume 40000 ft³ (1200 M3) 20000 ft³ (600 M3) 10000 ft³ (300 M3) Air Quality G2 G3 GX *Based on ISA S71.4 or ASHRAE TC9.9 recommendations Test Coupons for Lab Analysis PureAir offers Corrosion Classification Coupons, which measure the air quality in your data centre to ANSI/ISA standards. The test coupon is placed in the data centre for 30 days and returned to PureAir to be analyzed by our certified laboratory technicians. If you are unsure if you have an environment that is harmful to your hardware, this should be your first step. Data Centre Specifications Leading the Industry The following customers have implemented PureAir’s proven technology to ensure the highest level of environmental protection for their critical hardware: Barclays Bank Farmers Insurance Google Hewlett Packard HSBC Bank Innodata Data Clean Asia and PureAir Flitration have partnered together to offer testing and remediation of contamination issues throughout the Asia region. PureAir Filtration specializes in custom design solutions for a worldwide range of vapor phase air purification and contaminant control applications. PureAir Filtration designs and builds complete systems to meet the demands of ANSI/ISA S-71 environmental standard for protecting electronics. Are unseen, corrosive gasses killing the sensitive equipment in your data centre? Contact Data Clean for a test coupon and have your air quality tested today! 10 OUR PRODUCTS 1 1 2 3 4 7 9 10 8 6 6 5 1 1 2 3 5 6 6 7 8 9 10 4 THE CONTROLLED ENVIRONMENT SPECIALISTS 1 2 3 Prevent cold air from flowing through the rack and bypassing the equipment to be cooled and also prevent hot exhaust air from recirculating back to the cold face of the rack. Data Clean offers several types of blanking panels to accommodate every installation, configuration and budget. Close off the horizontal space between the floor and the bottom of the cabinet. Just a 1-inch vertical gap creates a 24- square inch opening for bypass airflow. Prevent cold air from flowing through the rack and bypassing the equipment to be cooled and also prevent hot exhaust air from recirculating back to the cold face of the rack. Data Clean offers several types of blanking panels to accommodate every installation, configuration and budget. Horizontal Blanking Panels Under Rack Panels Vertical Blanking Panels RACK SOLUTIONS 11 OUR PRODUCTS 4 7 9 8 10 5 6 Keep hot air from flowing out of cable openings in the top of a rack. Brush grommets with hybrid brush technology allow cables to pass through the top of the rack but keep air locked inside. Rack-face brush grommets allow cables to pass from the front to the rear of the rack while still blocking bypass airflow. Are the simplest solution for sealing cable cutouts to keep cold air under the floor where it belongs.Data Clean offers brush grommets in sizes and shapes for every opening. Unmanaged floor cutouts represent one of the biggest sources of bypass airflow and a significant reduction in cooling efficiency. Is the last big step toward achieving total isolation. Data Clean offers softwall curtain systems, hardwall systems and hybrid systems which include a combination of the two systems. Hot aisle or cold aisle containment can easily accommodate equip- ment rearrangements while improving your airflow management. Rack Brush Grommets Inter-Rack Barriers Active Fan Panels High Airflow Directional Panels Underfloor Plenum Baffles Aisle Containment Floor Brush Grommets AISLE SOLUTIONS Extend the aisle containment solution to narrow vertical spaces between adjacent racks or other infrastructure such as walls and columns. These field adjustable panels attach to the sides of racks and walls with magnetic strips or screws or adhesive tape. Provide with a 70° directional angle airflow to high- density equipment racks. Data Clean offers high airflow panels in several configurations including a 68% open panel that virtually doubles the airflow of a standard perforated panel. The Airboost Active Fan Panels are used to cool high-density racks or provide additional cooling in airflow starved areas. The AirBoost unit should be installed directly below a high- volume panel for maximum airflow and peak performance. The AirBoost Active Fan Panels are available in manual or remote sensor temperature controlled. Help direct conditioned air toward critical needs. Data Clean baffles are flexible, easy to cut, and easy to install. Reducing the volume of area to be cooled saves money. 12 OUR PRODUCTS THREE STEPS TO OPTIMIZED AIRFLOW KoldLok Grommets are designed to virtually eliminate bypass airflow from cable cut-outs, increase capacity, enable higher density and dramatically lower energy consumption. HotLok products reduce high intake air temperatures by preventing hot exhaust air from circulating to the front of the IT cabinets. This improves IT equipment reliability and supports cooling infrastructure optimization. KOLDLOK Raised Floor Airflow Management HOTLOK Rack Airflow Management KoldLok Wave Item No. 20100 Blanking Panel Mini Item No. 10077 Integral One Piece Split Blanking Panel with Temperature Strip Extended 3” Full Rack Blanking Panel Extended 6” Rack Airflow Management Kit Round 4” 6” 3” x 24” 3” x 60” 3” x 24” 3” x 60” 2.5” Roll @ 100’ 4.0” Roll @ 100’ 5.5” Roll @ 100’ 45” Profile @ 105’ 90” Profile @ 105’ Surface Mount Original Large XLarge Temperature Strip Round 4” Rack Mount Grommet Pass through Blanking Panel ® ® ® RAISED FLOOR Seal the Openings 1 RACK Control Intake Airflow 1 1 5 5 2 2 6 6 7 7 4 4 3 3 Item No. 1010 Item No. 3030 1U Item No. 10035 2U Item No. 10038 1U Item No. 10031 2U Item No. 10033 Item No. 10012 Item No. 10097 Item No. 10143-42U Item No. 10144-36U Item No. 10013 Item No. 10098 Item No. 10139 Item No. 10140 Item No. 10141 Item No. 10134 Item No. 10132 Item No. 40001 Item No. 40003 Item No. 2020 Item No. 2030 Item No. 2040 Item No. 10009 Item No. 10125 Item No. 40002 1U Item No. 10112 2U Item No. 10113 3” x 24” 3” x 60” 6” x 24” 6” x 60” (60 mm) 4.0" (100 mm) 5.5" (140 mm) 45 ̊ 90 ̊ (60 mm) 4.0" (100 mm) 45 ̊ 90 ̊ 2 13 OUR PRODUCTS 1 2 3 4 6 7 5 2 6 3 4 5 1 7 4 4 5 1 2 3 5 6 7 4 1 2 6 7 3 4 5 1 2 1 TM ROW Ensure Hot and Cold Aisle Separation 3 Aisle products are engineered to reduce bypass airflow, increase capacity, and improve PUE. AisleLok Modular Containment products are designed to provide the benefits of full containment, but with greater flexibility and better price value. AISLELOK Aisle Airflow Management ® Under Rack Panel Acrycell Sealing Tape 1 2 ½ ” Item No. 10108-001 1” Item No. 10108-002 2” Item No. 10108-003 27.5” Item No. 10126 31.5” Item No. 10127 14 OUR PRODUCTS A-S AIR SEAL Maintaining adequate under floor static pressure is one of the most important aspects for successful cooling of the data center. The Air-Brush floor grommet is intended for new installations to seal floor cut outs before the installation of power or communication cables. “Bypass air” is conditioned air that does not reach the intake of IT equipment. The elimination or reduction of “bypass air” is essential to the successful operation of the cooling dynamics of the data center. Air-Brush is the economical choice in raised floor grommets Air-Seal Raised Floor Grommets Promotes Hot Aisle/Cold Aisle best practices Increases overall room cooling capacity Increases the under floor static pressure Improves airflow where it is needed Advantages Face size: 201mm x 265mm x 30mm Cutout size: 160mm x 222mm Fire retardant ABS Polycarbonate Overlapping bristles for a better seal Specifications 15 OUR PRODUCTS PLENAFORM PLENAFORM Material Specifications: Die cut - Formex GK-40 Flame Retardant Polypropylene Compound RoHS and WEEE Compliant PLENAFORM™ Special Features: Physical Properties: Test Method Formex GK-40 Flammability UL94 V-0 PLENAFORM Baffle Dimensions: 24” h x 48” w x .040 Weight approx. 1.75 lbs. each Installs easily - Ships complete with screw rivets and cable ties Sheets are scored for easy sizing Fits any raised floor pedestal style Continuous hole pattern allows attachment at any location Cuts easily for passage of cables, conduit, cable trays and ductwork 16 OUR PRODUCTS EZIBlank blanking panels provide a cost effective way of improving your PUE by preventing unwanted air recirculation within a 19” enclosure. EZIBlank blanking panels keep hot exhaust air away from cool intake air, extending the life of IT equipment, saving energy and reducing the carbon footprint of the data center. EZIBlank blanking panels are supplied in 6U sheets and can be snapped at 1U intervals allowing them to fit the required amount of unused rack space,so there’s no more hunting around to find a blanking panel to fit the required space. EZIBLANK PANELS EZIBLANK prevents hot air recirculation, which is one measure that helps improve CRAC unit efficiency. 6U panels can be split at 1U intervals EZIBLANK panels are designed and manufactured to the highest international standards. Great for the environment, EZIBLANK panels are reusable, recyclable and flame retardant. Tool-less installation thanks to an innovative ‘pop-in clip’. Benefits Size: 19” EIA x 6U (Snaps off per 1U) Certifications: ANS UL 94 V-0 & UL E183535 Material: ABS Plastic Shipping Weight: 8.2 lbs per case (10 panels) Specifications Installation guide: EZINLSNK Installation, 6 x 1U Panel Place the panel in the required position and align the clips with 19” mounting holes Easy selection of individual panel combinations. Firmly bend along desired postion ...fold backward and “snap“ off as required Insert the adjusted panel to fill the remaining open rack space Push the clips firmly into postion on each side 17 OUR PRODUCTS EZIWALL Dimensions WARNING: “DO NOT LEAN” EziBlank 750 WARNING: “DO NOT LEAN” EziBlank 800 WARNING: “DO NOT LEAN” EziBlank 600 Containment Air Flow Control Dimensions A cost effective way to maintain important air flow dynamics within a Data Centre. These EZIBLANK®WALL replacement racks are assembled in minutes, creating a stable rack sized air flow barrier, that can be positioned anywhere and re-used again and again. Assembled from flat sheet, EZIBLANK®WALL panels build quickly into a strong, stable triangular structure. Each individual rack consists of 1 sheet of 2315mm x 2180mm. Easily construct a full height rack in seconds. Features A stable rack-sized air flow barrier that can be positioned anywhere. Quick to assemble from flat sheet into strong triangular structure. Suits various rack spaces up to 46RU high and 600 / 750 / 800mm wide. Prevents hot air recirculation in a hot or cold containment aisle. 3 Sizes in one. Simply “rotate” to obtain correct rack width. EZIBW48U-01PNL1 EZIBLANK®WALL Containment Air Flow Control Rack Replacement Panels. Suits 600mm, 750mm and 800mm wide Racks. Figure 1 Figure 3 Figure 6 Figure 2 Figure 5 Figure 4 Figure 7 Figure 10 Figure 11 Figure 8 Figure 9 Eziblank® Wall Installation Guide Rev 2 Bring the two vertical ends of the EziWall together making sure the VelcroTM tabs(Fig 1) are fixed together completing the EziWall structure (Fig2). In the instance when the 600mm side is the facing side the 200mm flap should be positioned on the outside {Fig 5 & Fig 6) and pinned on the top and bottom as shown above (Fig 7). This allows for a more aesthetically pleasing smooth curved corner on each vertical side of the 600 face Lay down the Ezi- Wall and proceed to split pin the aligned sides (Fig3). This should be done on the top and bottom of the Eziwall (Fig 4). Place the Eziwalls in the desired configuration. Pin the top end bottom of the vertical facing sides together (Fig 8 & 9). It Is advised to stabilize, by use of the feet, at least every fourth Eziwall in a particular suite. Fig 10 & 11 illustrate practical application of the EziWall. Using the simple instructions above, Ezi- Wall can be used to fill gaps or cavities from 600mm to a full suite of 30_ rack spaces. A stable suite of Eziwalls can be built by simply employing the supplied split pins. Dimensions: Weight: 2315mm x 2180mm 4.5kg per Rack Material: Flame retardant , impact resistant, water resistant, twin walled polypropylene sheet 6mm Available Colours: Black Physical Specifications: Ordering Information: 18 OUR PRODUCTS DC-68-D DIRECTIONAL HIGH OUTPUT AIRFLOW PANEL Maximum Cool Air For Maximium Efficiency The DC-68-D is a 70 degree directional tile that will put the cold air where you want it... directly into your server cabinet. A directional tile reduce air loss and the DC-68-Directional tile and it is a full 68% open area tile so you’ll get maximum amount of air to cool those high density servers. The DC-68D is made of cast aluminum so there is no worry of zinc whiskers or rust...ever! The DC-68-D has a factory applied, extremely durable, grey hammer-tone powder coat finish to prevent corrosion. The DC-68-D meets MOB PF2 PS, CISCA and BS EN 12825 standards for point load, uniform distributed load and rolling load. The DC-68-D is also available with a sliding damper so you can adjust the volume of air required for your particular application and equip- ment load. The DC-68-D damper has a slim profile so underfloor laminar airflow is not affected. DC-68-D Call Data Clean Asia for a no obligation demonstration of this new and innovative directional tile. Dimensions: Weight: Materials: Open Area: Available with sliding damper 600 x 600 x 55mm 8.8kg Cast Aluminum 68% Tile Specifications Testing by KRT Audit Corporation to meet CISCA standard concentrated load test: 660kg (1500Ib.) Effective Cooling For High Density Servers Improve Performace Increase Efficiency This smoke test shows how the 70° tile forces the smoke toward the cabinet 19 OUR PRODUCTS DC-55 HIGH VOLUME FLOOR TILES Dimensions: Weight: Material: Open Area: 600mm x 600mm x 45mm 7.8kg Cast Aluminum 568 Available with opposed blade louvre damper Testing by TUV/PSB Singapore to CISCA standards Concentrated Load Test: Safety Factor: Rolling Load: 6,500N/1,500lb 2.5 X 10,000 Passes @ 3,500N Deflection >0.3mm The Data Clean’s DC 55 Air Grate is a 600mm x 600mm cast aluminum floor grate with a minimum open area of 55% that delivers almost twice the CFM of the average perforated floor tiles. That mean it provides enough airflow to properly cool your high density equipment. The DC55 grate can be the solution to your hot spot problems by allowing air to flow high enough to cool those servers that are positioned close to the top of your server cabinets. The DC 55 has a factory applied, high durability, light grey powder coat finish to prevent corrosion and this heavy-duty perforated panel can withstand a point load of over 4.5KN (1,000lb per square inch) and a uniform distributed load of over 13.5KN (PSB test results available upon request). The DC 55 is also available with a louvered damper so you can adjust the volume of air needed for your particular application and equipment load. The louvered damper is adjustable from the top so you do not have to remove the tile to make those critical adjustments. The DC 55 damper assembly has a very small profile so the underfloor laminar air-flow is not affected. 20 OUR PRODUCTS AIRBOOST FAN ASSISTED FLOOR TILES THE CONTROLLED ENVIRONMENT SPECIALIST Manual Control or Remote Temperature Control to provide the required air-flow to critical servers.