The Controlled Environment Cleaning Specialists CONTANMINATION CONTROL/ PARTICLE COUNT/ INDOOR AIR QUALTY KOLDLOK / AISLELOK / PLENAFORM HIGH AIRFLOW PANELS HOTLOK / PLENAFILL / EZIBLANK HOT & COLD AISLE CONTAINMENT SOLUTIONS AIRFLOW ANALYSIS / ENERGY STUDIES / POWER QUALITY MONITORING ABOUT US 2 AIRFLOW MANAGEMENT SERVICES Data Clean has been serving its clients with Airflow Management Services since 2002. In the beginning, the goal was implementation of the new hot aisle/cold aisle concept. Today, the goal is total isolation of the hot and cold sides of the equipment. Simple in theory, implementation of total isolation can be challenging; particularly in existing facilities. Data Clean has developed the expertise to successfully guide our clients to total isolation in data centers around the world. The Data Clean Airflow Management Service is your choice for low cost, high impact solutions. Measure conditions and capacities Model solution technology Design solution Model solution financials Implement and install Data Clean understands that the path to total isolation is as varied as individual data center facilities. Our services adjust to fit your needs. The Path to Total Isolation Proper airflow management reduces energy, frees resources and saves money. IT LOAD COOLING Cooling can be half of the total energy consumed in a data center Cold air is wasted if not properly managed OTHER Proper isolation is critical to achieve cooling efficiency Data Center Power Consumption Efficient Cooling Directs airflow through, not around IT equipment The Path to Total Isolation Prevents Equipment Rack Equipment Rack CRAC / CRAH bypass airflow Eliminates hot air recirculating directly to IT equipment Reach Your Goals with Data Clean Eliminate Bypass Airflow • Raise Set Points • Lower PUE • Eliminate Hot Spots Support Higher Density Installations • Reduce Cost ABOUT US 3 SETTING THE STANDARD IN CRITICAL ENVIRONMENT CLEANING Why Choose Data Clean? Data Clean customers choose Data Clean because we do more and we do it better. Insured • Trained • Tested Experience Known Worldwide Recommended Insured & Secure Data Clean operates Full-service Some of the most respected and Data Clean is fully insured and branches around the globe and trusted companies in the IT and our service technicians wear maintains thousands of controlled communications industries use uniforms and photo IDs for your environments worldwide – visit Data Clean to maintain their critical protection. Technicians are www.dataclean.com to locate environments. Ask your Data Clean subject to random drug and a branch near you. Account Manager for references. alcohol testing. Highly Trained Technicians Flexible 24/7 Scheduling 100% Satisfaction Guaranteed & Emergency Services Data Clean technicians are Schedule your cleaning and The Data Clean 100% Satisfaction thoroughly trained to work maintenance services when Guarantee is our ongoing promise around the sensitive equipment it’s convenient for you and to you that we will do whatever it in today’s state-of-the-art the needs of your business. takes to make sure you are datacom environments. totally satisfied.. Your Data is Worth Millions Why Risk It? A dirty environment creates the risk of equipment failure and downtime caused by contamination. Left unchecked, contaminates accumulate and can cause equipment overheating due to clogged filters and heatsinks, or even create direct short circuits.Data Clean understands your environment is unique and we will develop a custom maintenance program to ensure your facility operates as reliably and efficiently as possible. A well maintained facility yields many benefits: EQUIPMENT FACILITIES PEOPLE High Reliability Energy Efficient Healthy Environment Maximum Uptime Professional Image Improved Productivity Data Clean technicians are experts. They have the training, tools and experience required to safely and effectively clean a variety of datacom environments Data Centers Telecom Facilities Construction Sites Server Rooms Video HeadEnds Non-Traditional Environments Computer Rooms Electrical Rooms IDF/MDF Rooms ABOUT US 4 CRITICAL ENVIRONMENT CLEANING 1 1 2 2 55 44 3 3 Consulting and Specialty Services Data Clean offers specialty services to help clients reduce the risk of downtime: Facility Surveys Zinc Whisker Testing & Remediation Contaminant Identification & Evaluation Gaseous Contamination Testing & Remediation Airborne Particle Counts ABOUT US 5 1 2 Ceiling Overhead Cable trays, lighting, ductwork,and piping are all areas of your Data Center that are outof sight and often neglected. Not only do harmful dustparticles settle on the equipment in the room, but also accumulate on the overhead components. Building vibration and airflow changes can Ceiling plenum cleaning is especially important when the plenum is dislodge settled particulate. used for return air. Airborne particulate can settle on building structure and MEP systems. Building vibration and airflow changes can cause existing settled contaminants to become airborne and burden CRAC/ CRAH filters or contaminate equipment below. 3 4 Underfloor Floors Underfloor plenum Floor surface cleaning removes cleaning removes ground-in contaminates which settled particulate diminish the built-in conductivity to prevent it from of the floor surface.The dirtier the becoming airborne floor, the lower floor’s ability to and ultimately dissipate potentially dangerous harming sensitive static electricity. Data Clean datacom equipment maintains all types of flooring, or activating including: High Pressure Laminate smoke detectors. (HPL) epoxy, vinyl, and carpet. 5 6 Equipment & Environmental Construction Whether it’s cleaning only During construction the outside of equipment is exactly when an racks and cabinets or on-line environment cleaning inside the actual requires additional IT equipment, Data Clean cleaning to ensure offers 5 different levels of reliable operation. equipment cleaning to meet Data Clean your every need. Data Clean provides both also cleans the environment Clean-Construction and support equipment from Cleaning and Final the floor to the ceiling and Clean Services. everything in between. ABOUT US 6 THE CONTROLLED ENVIRONMENT CLEANING SPECIALISTS Since 1979, we at Data Clean have been providing a high quality maintenance services for a variety of controlled environments, extending beyond cleanrooms to all other critical environments as well. CleanRooms Data Clean uses proven techniques to remove dirt, dust, and other contaminants from your cleanroom, from those visible to the eye, to more importantly, those that are not visible at all. Data Clean’s trained technicians use specialized cleaning solutions - time tested for use in clean rooms. Our HEPA or ULPA filtered vacuums are certified to 0.3 microns and 0.1 microns, respectively, and remove even the smallest of micro-particles from your facility. We are able to clean from floor to ceiling. No area is out of our reach. Before a Data Clean Technician is sent into the field he must successfully complete a comprehensive training program which covers specific cleaning techniques particular to your operational needs keeping in mind delicate electronic equipment. Through strict adherence to standard operating procedures, Data Clean cleaning technicians follow strict protocol, we thereby offering a service standard par excellence. All our workers have expert knowledge of a range of contamination methods and are equipped with the requisite skill set to meet all your critical environment cleaning needs. Whether your needs are construction cleaning or daily maintenance, Data Clean technicians can perform all aspects of clean room cleaning - from construction cleaning to daily maintenance. ABOUT US 7 HOW CLEAN DO YOU WANT YOUR CLEANROOM TO BE? Data Clean offers the following clean room cleaning services performed on a variable frequency. Service frequency ranges from a one-time event to daily maintenance. The scope of each service is adjusted based on the existing level of facility cleanliness and the target level of cleanliness. Cleanrooms: ISO 14644 - 1: Class 1 - Class 9 Fed. Std. 209E: Class 1 - Class 100,000 Whether your cleanroom is a small soft-wall enclosure or high standard of cleanliness must be maintained in order to maintain the process or product yield. Equipment Cleaning Data Clean will collaborate with you with regard to your established cleaning practices and even go one step further, by working with you to enhance your cleaning protocols resulting in your improved productivity. Data Clean Cleaning technicians are experts at cleaning and removing harmful contaminates such as dirt, dust and residues from the exterior surfaces on your support equipments and all areas in the control room environments. Portable Particle Counters Particle counters are required equipment for certifying and testing cleanrooms, data centres and other critical environments. These critical measurements to comply with ISO 14644-1 and various GMP regulations worldwide. ABOUT US 8 SELF-CONTAINED DATA CENTRE AIR PURIFIER Keep electronics safe from corrosive pollutants - while improving indoor air quality Capture harmful gases in your data centre The PureAir DC-1000 is a self-contained, moveable unit that recirculates the air in data centers. As the air passed through PureAir’s gas adsorbent media, harmful corrosive gases are captured and permanently bound. Purified air is sent out the top of the DC-1000 where it is used to cool servers without harming electrical components. Long-ranging, easy protection The DC-1000 has low energy consumption and noise, and installation is a snap in your existing server cabnets, plugging into standard electrical sockets. Each unit provides protection for up to 5000 square feet (approximately 500 M2). Airflow is variable, controllable up to 1000 cfm (1700 CMH), and differential pressure gauges indicate filter changes for easy maintenance. ABOUT US 9 Data Centre Specifications Features MERV 7 (G4) Dust Prefilter 4 cubic feet (113 liters) of PureAir gas adsorbent media filled in low pressure holding frames MERV 14 (F8) Dust Final Filter Available with 110-230V and 50/60 V options Differential pressure gauges to indicate dust filter changes Low energy consumption - 0.7 kW Low noise Each unit provide protection for up to 5000 square feet (approx 500 M2) Variable control of airflow up to 1000 cfm (1700CMH) Low EMF brushless AC blower motor Unit Sizing Air Quality Room Air Volume G2 40000 ft³ (1200 M3) G3 20000 ft³ (600 M3) GX 10000 ft³ (300 M3) *Based on ISA S71.4 or ASHRAE TC9.9 recommendations Leading the Industry Test Coupons for Lab Analysis The following customers have implemented PureAir’s PureAir offers Corrosion Classification Coupons, which proven technology to ensure the highest level of measure the air quality in your data centre to ANSI/ISA environmental protection for their critical hardware: standards. The test coupon is placed in the data centre for 30 days and returned to PureAir to be analyzed by Barclays Bank Hewlett Packard our certified laboratory technicians. If you are unsure Farmers Insurance HSBC Bank if you have an environment that is harmful to your Google Innodata hardware, this should be your first step. Data Clean Asia and PureAir Flitration have partnered together to offer testing and remediation of contamination issues throughout the Asia region. PureAir Filtration specializes in custom design solutions for a worldwide range of vapor phase air purification and contaminant control applications. PureAir Filtration designs and builds complete systems to meet the demands of ANSI/ISA S-71 environmental standard for protecting electronics. Are unseen, corrosive gasses killing the sensitive equipment in your data centre? Contact Data Clean for a test coupon and have your air quality tested today! OUR PRODUCTS 10 THE CONTROLLED ENVIRONMENT SPECIALISTS 6 4 6 6 1 2 7 1 8 9 3 5 5 10 RACK SOLUTIONS 1 2 3 Horizontal Blanking Panels Vertical Blanking Panels Under Rack Panels Prevent cold air from flowing through the rack and bypassing the equipment to be cooled and also prevent hot exhaust air from Prevent cold air from flowing through Close off the horizontal space between recirculating back to the the rack and bypassing the equipment to be the floor and the bottom of the cabinet. Just a cold face of the rack. cooled and also prevent hot exhaust air from 1-inch vertical gap creates a 24- square inch Data Clean offers several recirculating back to the cold face of the rack. opening for bypass airflow. types of blanking panels Data Clean offers several types of blanking to accommodate every panels to accommodate every installation, installation, configuration configuration and budget. and budget. OUR PRODUCTS 11 AISLE SOLUTIONS 4 5 6 Rack Brush Grommets Floor Brush Grommets Aisle Containment Is the last big step toward achieving total isolation. Data Clean offers softwall curtain systems, hardwall systems and hybrid systems which include a combination of the Keep hot air from flowing out of cable Are the simplest solution for sealing cable two systems. Hot openings in the top of a rack. Brush grommets cutouts to keep cold air under the floor aisle or cold aisle with hybrid brush technology allow cables to where it belongs.Data Clean offers brush containment can easily pass through the top of the rack but keep air grommets in sizes and shapes for every accommodate equip- locked inside. Rack-face brush grommets opening. Unmanaged floor cutouts ment rearrangements allow cables to pass from the front to the rear represent one of the biggest sources of while improving your of the rack while still blocking bypass airflow. bypass airflow and a significant reduction airflow management. in cooling efficiency. 7 8 Inter-Rack Barriers High Airflow Directional Panels Extend the aisle containment solution to Provide with a 70° directional angle narrow vertical spaces between adjacent airflow to high- density equipment racks or other infrastructure such as walls racks. Data Clean offers high airflow and columns. These field adjustable panels panels in several configurations attach to the sides of racks and walls with including a 68% open panel that magnetic strips or screws or adhesive tape. virtually doubles the airflow of a standard perforated panel. 9 10 Active Fan Panels Underfloor Plenum Baffles The Airboost Active Fan Panels are used to Help direct conditioned air toward critical cool high-density racks or provide additional needs. Data Clean baffles are flexible, easy cooling in airflow starved areas. The AirBoost to cut, and easy to install. Reducing the unit should be installed directly below a high- volume of area to be cooled saves money. volume panel for maximum airflow and peak performance. The AirBoost Active Fan Panels are available in manual or remote sensor temperature controlled. OUR PRODUCTS 12 THREE STEPS TO OPTIMIZED AIRFLOW 1 RAISED FLOOR Seal the Openings 2 RACK Control Intake Airflow ® ® KOLDLOK Raised Floor Airflow Management HOTLOK Rack Airflow Management KoldLok Grommets are designed to virtually HotLok products reduce high intake air temperatures by eliminate bypass airflow from cable cut-outs, preventing hot exhaust air from circulating to the front increase capacity, enable higher density and of the IT cabinets. This improves IT equipment reliability dramatically lower energy consumption. and supports cooling infrastructure optimization. KoldLok Wave® 1 Blanking Panel 1 Item No. 20100 1U Item No. 10031 2U Item No. 10033 2 Integral 2 Blanking Panel with Temperature Strip One Piece Item No. 1010 1U Item No. 10035 Split Item No. 3030 2U Item No. 10038 3 Surface Mount 3 Temperature Strip Original Item No. 2020 Item No. 10009 Large Item No. 2030 Item No. 10125 XLarge Item No. 2040 4 Mini 4 Round 4” Rack Mount Grommet Item No. 10077 Item No. 40002 5 Round 5 Pass through Blanking Panel 4” Item No. 40001 1U Item No. 10112 6” Item No. 40003 2U Item No. 10113 6 Extended 3” 3” x 24” 3” x 60” 6 Full Rack Blanking Panel 3” x 24” Item No. 10012 Item No. 10143-42U 3” x 60” Item No. 10097 Item No. 10144-36U 7 Extended 6” 6” x 24” 6” x 60” 7 Rack Airflow Management Kit 45˚ 90˚ (60 mm) 3” x 24” Item No. 10013 2.5” Roll @ 100’ Item No. 10139 3” x 60” Item No. 10098 4.0” Roll @ 100’ Item No. 10140 4.0" (100 mm) 5.5" 5.5” Roll @ 100’ Item No. 10141 (140 mm) 45” Profile @ 105’ Item No. 10134 90” Profile @ 105’ Item No. 10132 45˚ 90˚ (60 mm) 4.0" (100 mm) OUR PRODUCTS 13 3 77 55 33 7 11 4 2 44 66 55 2 5 66 22 1 41 1 4 3 ROW Ensure Hot and Cold Aisle Separation ® AISLELOK Aisle Airflow Management Aisle products are engineered to reduce bypass airflow, increase capacity, and improve PUE. AisleLok Modular Containment products are designed to provide the benefits of full containment, but with greater flexibility and better price value. 1 Under Rack Panel 27.5” Item No. 10126 31.5” Item No. 10127 2 AcrycellTM Sealing Tape ½” Item No. 10108-001 1” Item No. 10108-002 2” Item No. 10108-003 OUR PRODUCTS 14 A-S AIR SEAL Maintaining adequate under floor static pressure is one of the most important aspects for successful cooling of the data center. The Air-Brush floor grommet is intended for new installations to seal floor cut outs before the installation of power or communication cables. “Bypass air” is conditioned air that does not reach the intake of IT equipment. The elimination or reduction of “bypass air” is essential to the successful operation of the cooling dynamics of the data center. Air-Brush is the economical choice in raised floor grommets Advantages Specifications Promotes Hot Aisle/Cold Aisle best practices Face size: 201mm x 265mm x 30mm Cutout size: Increases overall room cooling capacity 160mm x 222mm Increases the under floor static pressure Fire retardant ABS Polycarbonate Improves airflow where it is needed Overlapping bristles for a better seal Air-Seal Raised Floor Grommets OUR PRODUCTS 15 PLENAFORM PLENAFORM Material Specifications: Die cut - Formex GK-40 Flame Retardant Polypropylene Compound RoHS and WEEE Compliant Physical Properties: Test Method Formex GK-40 Flammability UL94 V-0 PLENAFORM Baffle Dimensions: 24” h x 48” w x .040 Weight approx. 1.75 lbs. each PLENAFORM™ Special Features: Installs easily - Ships complete with screw rivets and cable ties Sheets are scored for easy sizing Fits any raised floor pedestal style Continuous hole pattern allows attachment at any location Cuts easily for passage of cables, conduit, cable trays and ductwork OUR PRODUCTS 16 EZIBLANK PANELS EZIBlank blanking panels provide a cost effective way of improving your PUE by preventing unwanted air recirculation within a 19” enclosure. EZIBlank blanking panels keep hot exhaust air away from cool intake air, extending the life of IT equipment, saving energy and reducing the carbon footprint of the data center. EZIBlank blanking panels are supplied in 6U sheets and can be snapped at 1U intervals allowing them to fit the required amount of unused rack space,so there’s no more hunting around to find a blanking panel to fit the required space. Benefits EZIBLANK prevents hot air recirculation, which is one measure that helps improve CRAC unit efficiency. 6U panels can be split at 1U intervals EZIBLANK panels are designed and manufactured to the highest international standards. Great for the environment, EZIBLANK panels are reusable, recyclable and flame retardant. Tool-less installation thanks to an innovative ‘pop-in clip’. Specifications Size: 19” EIA x 6U (Snaps off per 1U) Certifications: ANS UL 94 V-0 & UL E183535 Material: ABS Plastic Shipping Weight: 8.2 lbs per case (10 panels) Installation guide: EZINLSNK Installation, 6 x 1U Panel Place the panel in the required position and Push the clips firmly into postion on each side align the clips with 19” mounting holes Easy selection of individual panel combinations. ...fold backward and “snap“ off as required Insert the adjusted panel to fill the remaining Firmly bend along desired postion open rack space OUR PRODUCTS 17 EZIWALL Containment Air Flow Control A cost effective way to maintain important air flow dynamics within a Data Centre. These EZIBLANK®WALL replacement racks are assembled in minutes, creating a stable rack sized air flow barrier, that can be positioned anywhere and re-used again and again. Assembled from flat sheet, EZIBLANK®WALL panels build quickly into a strong, stable triangular structure. Each individual rack consists of 1 sheet of 2315mm x 2180mm. Easily construct a full height rack in seconds. Features Dimensions A stable rack-sized air flow barrier that can be positioned anywhere. Dimensions Quick to assemble from flat sheet into strong triangular structure. Suits various rack spaces up to 46RU high and 600 / 750 / 800mm wide. Prevents hot air recirculation in a hot or cold containment aisle. 3 Sizes in one. Simply “rotate” to obtain correct rack width. Specifications: EziBlank 750 EziBlank 800 EziBlank 600 Physical WARNING: WARNING: WARNING: Dimensions: Weight: “DO NOT LEAN” “DO NOT LEAN” “DO NOT LEAN” 2315mm x 2180mm 4.5kg per Rack Material: Flame retardant , impact resistant, water resistant, twin walled polypropylene sheet 6mm Available Colours: Black Ordering Information: EZIBW48U-01PNL1 EZIBLANK®WALL Containment Air Flow Control Rack Replacement Panels. Suits 600mm, 750mm and 800mm wide Racks. Eziblank® Wall Installation Guide Rev 2 Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Bring the two vertical ends of the Lay down the Ezi- This should be In the instance when the 600mm side is the facing side the 200mm EziWall together making sure the Wall and proceed to done on the top flap should be positioned on the outside {Fig 5 & Fig 6) and pinned VelcroTM tabs(Fig 1) are fixed together split pin the aligned and bottom of on the top and bottom as shown above (Fig 7). This allows for a more completing the EziWall structure (Fig2). sides (Fig3). the Eziwall (Fig 4). aesthetically pleasing smooth curved corner on each vertical side of the 600 face A stable suite of Eziwalls can be built by simply employing the supplied split pins. Place the Eziwalls in the Fig 10 & 11 illustrate practical desired configuration. Pin application of the EziWall. the top end bottom of the Using the simple instructions vertical facing sides together above, Ezi- Wall can be used (Fig 8 & 9). It Is advised to to fill gaps or cavities from stabilize, by use of the feet, 600mm to a full suite of at least every fourth Eziwall 30_ rack spaces. Figure 8 Figure 9 in a particular suite. Figure 10 Figure 11 OUR PRODUCTS 18 DC-68-D DIRECTIONAL HIGH OUTPUT AIRFLOW PANEL Maximum Cool Air For Maximium Efficiency Call Data Clean Asia for a no obligation demonstration of this new and innovative directional tile. DC-68-D The DC-68-D is a 70 degree directional tile that will put the cold air where you want it… directly into your server cabinet. A directional tile reduce air loss and the DC-68-Directional tile and it is a full 68% open area tile so you’ll get maximum amount of air to cool those high density servers. The DC-68D is made of cast aluminum so there is no worry of zinc whiskers or rust…ever! The DC-68-D has a factory applied, extremely durable, grey hammer-tone powder coat finish to prevent corrosion. The DC-68-D meets MOB PF2 PS, CISCA and BS EN 12825 standards for point load, uniform distributed load and rolling load. The DC-68-D is also available with a sliding damper so you can adjust the volume of air required for your particular application and equip- ment load. The DC-68-D damper has a slim profile so underfloor laminar airflow is not affected. Effective Cooling For High Density Servers Improve Performace Increase Efficiency Tile Specifications Dimensions: 600 x 600 x 55mm Weight: 8.8kg Materials: Cast Aluminum Open Area: 68% Available with sliding damper This smoke test shows how the 70° tile forces the smoke toward the cabinet Testing by KRT Audit Corporation to meet CISCA standard concentrated load test: 660kg (1500Ib.) OUR PRODUCTS 19 DC-55 HIGH VOLUME FLOOR TILES The Data Clean’s DC 55 Air Grate is a 600mm x 600mm cast aluminum floor grate with a minimum open area of 55% that delivers almost twice the CFM of the average perforated floor tiles. That mean it provides enough airflow to properly cool your high density equipment. The DC55 grate can be the solution to your hot spot problems by allowing air to flow high enough to cool those servers that are positioned close to the top of your server cabinets. The DC 55 has a factory applied, high durability, light grey powder coat finish to prevent corrosion and this heavy-duty perforated panel can withstand a point load of over 4.5KN (1,000lb per square inch) and a uniform distributed load of over 13.5KN (PSB test results available upon request). The DC 55 is also available with a louvered damper so you can adjust the volume of air needed for your particular application and equipment load. The louvered damper is adjustable from the top so you do not have to remove the tile to make those critical adjustments. The DC 55 damper assembly has a very small profile so the underfloor laminar air-flow is not affected. Dimensions: 600mm x 600mm x 45mm Concentrated Load Test: 6,500N/1,500lb Weight: 7.8kg Safety Factor: 2.5 X Material: Cast Aluminum Rolling Load: 10,000 Passes @ 3,500N Open Area: 568 Deflection >0.3mm Available with opposed blade louvre damper Testing by TUV/PSB Singapore to CISCA standards OUR PRODUCTS 20 AIRBOOST FAN ASSISTED FLOOR TILES THE CONTROLLED ENVIRONMENT SPECIALIST Manual Control or Remote Temperature Control to provide the required air-flow to critical servers. OUR PRODUCTS 21 The AirBoost fan assisted system offers direct cooling to those hard to cool areas where clusters of high-density servers have created hotspots or where air-flow is low due to underfloor restrictions. The AirBoost is available in a manual controlled unit that allows an infinite adjustment of air-flow depending on the amount needed to cool an area or a temperature controlled unit that supports up to three remote temperature sensors to control fan speed as the temperature increases or decreases. No downtime or movement of racks is required for the installation of an AirBoost unit and one AirBoost can provide cooling for two or three adjacent racks. If larger areas require cooling, multiple AirBoost units can be used at the same time. AirBoost can be considered a “greening” solution as well. Many times data centers are kept cooler than necessary just to cool a few high density areas. This over-cooling is used to keep the hostspots under control but with an AirBoost solution in place, the overall room temperature can be increased as the AirBoost will control the individual problematic hotspots without requiring an over-cooled data center. Temperature Controlled AirBoost 100 90 The Temperature Controlled AirBoost is designed to support connection to a BMS (Building FA N SPEED (%) 80 Management System). The Airboost can report both “unit failure” as well as “pre-set maximum 70 temperature exceeded”. The Nimbus SmartFan® controller by Control Resources Incorporated, 60 Temperature Controlled AirBoost controls the fan speed from temperature signals received from the 1 to 3 remote temperature 50 40 sensors. The speed of the fans will increase or decrease according to temperature changes. 30 The minimum or idle fan speed can be set at 30%, 40% or 50% depending on required 20 constant air-flow. 10 20°C 21°C 22°C 23°C 24°C 25°C 26°C 27°C 28°C 29°C 73.4°F 82.4°F *The graph shows the relationship of fan speed to temperature Fan Specification Wall ring: Die Cast Aluminium Type of protection: IP 44 Blades: Sheet Steel, Coated in Black Insulation Class: B Number of Blades: 7 Bearings: Maintenance-Free Ball Bearings RPM: 2,550 Motor Protection: TOP Wired Internally Ratings: FAN SPECIFICATION 60,000 Hours @ 30oC Protection Class: I Approvals: VDE, UL, CSA, CCC, GOST Product Conforming to Standards: EN 60335-1,CE AIRFLOW AIRFLOW EVALUATION #1 EVALUATION #2 Underfloor Static Pressure Underfloor Static Pressure 0.029 inches / H²O 0.013 inches / H²O Air Flow with AirBoost Air Flow with AirBoost High: High: Medium: 1,696 CFM Medium: 1,508 CFM Low: 1,410 CFM Low: 1,350 CFM 960 CFM 725 CFM Off: Off: 539 CFM 240 CFM Voltage: 230 Volts (110V also available) Cord Length: 360 cm (12 ft) Current: Low speed 0.86 Amps, High speed 1.28 Amps Dimensions: 565mm x 565mm x 95mm Inrush 2.9 Amps to 2.3 Amps in 5 seconds Weight: 14.5kg Plug type: 15 Amp, British Standard Warranty: 1 year Product designed by DCA Pte Ltd and manufactured by EBM-Papst in a certified ISO9001 manufacturing environment White paper/ evaluation available on our website for downloading. OUR PRODUCTS 22 DATA CLEAN ASIA-THE INDUSTRY LEADER IN CONTAINMENT SOLUTIONS! TRAX Full Containment Cost- effective Fire rated Soft Wall full containment solutions. AisleLok Modular and tool-less Installation AisleLok Doors Simplex Full Containment with melt away Plastic Panels OUR PRODUCTS 23 TRAX Door Custom made soft wall single/double sliding doors. Custom Door Custom made rigid sliding/swing doors OUR PRODUCTS 24 TRAX AISLE CONTAINMENT SOLUTIONS AISLE CONTAINMENT in the last couple of years has become the next logical step from hot and cold aisles due to the improvement of cooling efficiency. Aisle Containment Solutions from TRAX Industrial Products Corporation isolate the cold or hot aisle to significantly reduce energy usage and increase both cooling efficiency and server reliability. Depending on the size and environmental specifications of individual data centers, the cooling requirements and energy costs could be reduced by up to 30% Fire suppression has always been the roadblock to aisle containment. Data Clean Asia and TRAX have together developed an approved solution to enable the installation of containment around gas or water based fire suppression systems. To address fire safety concerns, curtains are attached to ceiling with heat-sensitive fusible links. Fuse Links Themal fuse-link is made of two pieces of metal with soft solder in between that allows the curtains to drop when room temperatures reach 57°C. UL listed Electro-mechanical McCabe Links with 165°F temperature rating are suitable for gas based fire suppression system. Electro mechanical links are magnetic links that when a signal from the fire suppression system is sensed, the curtain drop. This UL 33 listed Fire Links are available in both Thermal and Thermal Electric versions. Electromagnetic Drop Link NFPA 2013 requires data centers to be outfitted with electronic drops links so that curtains fall away in the event of fire, allowing sprinklers or the fire suppression agent to circulate freely. AirBlock Electronic Fuselink are designed to operate flawlessly and reliably in the data center environment. Each magnet and housing assembly supports an eight-foot-length of floor-to-celling curtain mounted to the aluminum bar. OUR PRODUCTS 25 SEAL-TECH Attachment System provided with TRAX curtains assures rapid, hassle free installation. After the clear anodised aluminum mounting extrusion is installed, the curtains quickly hang in place, and are secured with a matching cap extrusion. TRAX curtains can be customised to meet the specific requirement of any facility. TRAX materials meet California State Fire Marshall standards. TRAX’s ESD Safe Seden Crystal Anti-Static PVC meets ASTM E-84: NFPA Class A & UBC Class 1 Flame Spread and Smoke Density Standards and is NFPA 701 compli- ant. Going Green with TRAX Aisle Containment Curtains for Data Centers provides a fast, low-cost solution to better cooling, greater productivity, and significant energy savings. SEAL-TECH the most user friendly attachment system OUR PRODUCTS 26 AIRBLOCK AISLE CONTAINMENT CEILING SYSTEM Save money and time with the AirBlock Aisle Containment Ceiling System. Our simple design and quality materials are the ideal solution for maximizing efficiency and controlling temperatures in both hot aisle and cold aisle containment applications. AirBlock also comes with melt-away ceiling tiles, allowing you to meet the requirements of your local fire marshal. Features: This cleanroom-grade, fully gasketed 2-inch T-bar grid Support lights, tiles, fan units and ductwork for uses standard 2’ by 4’ ceiling panels, and is designed hot-aisle containment, or use with cold aisle for maximum strength. containment applications. Grid comes pre-assembled for quick installation, or Available with new U.L.- approved, FM-approved, order as an easy-to-assemble kit. Install to the top of melt-away ceiling tiles that accommodate your the rack using fully adjustable Z-bars or riser panels overhead sprinkler system. Choose from clear or for added height and clearance. eggshell white. Panels drop into place and trim easily for smaller openings. The aluminum alloy extrusion that is the basis of the AirBlock ceiling system incorporates a unique threaded track in case your application calls for installation from suspended cable trays or an existing ceiling. Protecting Critical Environments for Over 30 Years. Threaded track Pre-assembled ceiling grids allow for easy and quick installation in your The specialized extrusion that makes up the modular AirBlock Aisle data center. Containment Ceiling System includes a threaded channel from overhead ceilings or cable trays (if desired). Note that the connecting hardware also accommodates overhead threaded rods. . OUR PRODUCTS 27 THE AIRBLOCK PRO-GLIDE MODULAR SLIDING DOOR Airblock brings you the ultimate in elegance and functionality in this latest door from the AirBlock line of data center products. Look at these features and see why: Features: Easy-glide track system operates smoothly. The self-aligning doors require no adjustment. Sweep seal and perimeter gasketing provides maximum containment. Anodized aluminum framing – in clear and black finish – for strength and weight savings. No protruding header or track assembly, allowing for a sleek, simple design. Exclusive self-closing cartridge converts from manual to self-closing in minutes. Inserts range from polycarbonate to flexible vinyl materials. Doors come together with a self-sealing magnetic gasket for a 100% seal. No air loss. Other Features: Single doors up to three feet wide. Double doors to six feet wide. Self-closer adjusts for speed and soft close. Door is pre-hung and installs in minutes. Take advantage of our quick-ship program. The easy-glide track system and self-closing cartridge, key features of the Series 1 Door, are integrated into the door so that they are tucked away from view when the doors are either closed or open. OUR PRODUCTS 28 ® AISLELOK - A NEW APPROACH TO CONTAINMENT AisleLok® Modular Containment Rack Top Vertical Baffle Hot Aisle Rack Top Angle Baffle Cold Aisle offers the samecore airflow Configuration Configuration management benefits of traditional containment solutions, but with the major advantage of saving time and money upfront. The key benefit AisleLok® Modular Containment offers is rapid deployment with little or no disruption to existing operations, and the ability to reconfigure the installation as the needs of the computer room change. And with no 3rd party required for design or installation, it’s affordable enough to deploy over multiple aisles or rooms. Bi-Directional Doors Cooling Cooling Unit Unit Typical Air Flow Patterns without Aislelok® Modular Containment Typical Air Flow Patterns with Aislelok® Modular Containment After Before (AisleLok ® Modular (No Containment) Containment) Temperature (F) Analysis and Testing 80.6 ˚ 78.4 ˚ 76.3 ˚ Extensive CFD analysis on the AisleLok® Modular 74.2 ˚ Containment design shows that thesolution can reduce server inlet temperatures by as much as 20°F in some conditions. On-site computer 72.0 ˚ room testing of large financial and government institutions yielded similar results. CFD Analysis shows hot air After AisleLok ® Modular recirculation into the cold aisle. Containment is installed, cold air is effectively contained, decreasing server inlet temps. OUR PRODUCTS 29 ® AISLELOK - MODULAR CONTAINMENT PRODUCTS U.S. and International Patents Pending Rack Top Baffle Prevents hot exhaust air from wrapping over the tops of racks and mixing with cold air. Made of clear polycarbonate Attaches to top of rack magnetically Vertical Angular baffle designed for cold aisle application Vertical baffle is designed for hot aisle application Angle UL94V flammability rated materials Bi-Directional Doors Prevents hot exhaust air from wrapping around the sides of racks and mixing with cold air. Made of clear polycarbonate Swing inward or outward when pushed; rest at center Attaches to side of rack magnetically Designed to allow carts to push through Features door stop kick-stand to remain open Can be applied to hot or cold aisle UL94V Flammability rated materials Adjustable Rack Gap Panel Blocks spaces between racks to prevent hot and cold air mixing. Attaches magnetically between two racks or other metal surface. Adjusts to fill in space between racks, from 10” to 60” (250mm to 1500mm). OUR PRODUCT 30 WHY CHOOSE CONTAINMENT? Hot aisle and cold aisle cabinet positioning in the data centre has been standard procedure for decades. But in recent years, data centre managers, seeking the opportunity for more efficiency, have added containment to this formula. Containment means partitioning off the hot or cold aisles, preventing the air from mixing and compromising the temperatures. This has been a vast improvement for maintaining temperatures in the data centre, providing maximum system stability and controlling energy costs. By preventing the mixing of cold air and hot exhaust air, dramatic improvements can be made to a facility’s cooling efficiency. This improve- ment is due to warmer air temperatures being returned to the CRAC units, which effectively improves CRAC operating efficiencies. With cold/hot aisle containment, cost savings can be between 10% and 30% on current building cooling systems. The end of aisle doors are the simplest containment solution for sealing off standard hot or cold aisles in any data center. This quick-fix containment solution can immediately stop CRAC unit short-cycling and improve CRAC cooling efficiency. Total containment solutions where the entire aisle is enclosed, can add even more energy savings resulting in lower data centre cooling costs. Benefits and Savings Eliminate hot spots Support 4x higher heat and power densities (6 kW to 30+ kW) Effectively utilize 100% of supplied air and reduce chilled air waste Improve CRAC efficiency because of higher supply-to-return temperature differences (Delta T’s) Allow increased room temperature and higher set points on cooling equipment and chilled water temperatures, resulting in less electricity consumption using low-cost economizers Provide flexibility for supply air delivery through the ceiling, wall or floor Custom Aisle Containment Solutions Data Clean offers many containment solutions from several different, indus- try recognized, solution providers. However, since every data centre is dif- ferent and has its own set of unique cooling issues, Data Clean can custom design a containment solution that is just right for your data centre applica- tion. Call us for a no cost, in-depth review of your data centre and a discussion of our various containment products. CONTACT US 31 Tokyo Seoul Japan Beijing South Korea China Taipei Taiwan Hong Kong Hanoi Philippines Manila Vietnam Thailand Bangkok Phnom Penh Cambodia Malaysia Kuala Lumpur Indonesia Singapore Indonesia Data Clean Asia [email protected] www.datacleanasia.com Data Clean Asia (HK) Ltd Tel: (852) 2959 1298 Email: [email protected] Data Clean Asia (M) Sdn Bhd Tel: (60) 3 77836511/12 Email: [email protected] Data Clean Asia Indonesia Tel: (6221) 252 6557 Email: [email protected] Data Clean Shanghai Co., Ltd Tel: (21) 5170 7858 Email: [email protected] Data Clean Asia Pte Ltd (Asia Corporate Office) Data Clean Korea Co Tel: (65) 6748 5377 Tel: (82) 02 515 7561 Email: [email protected] Email: [email protected] Website: www.datacleanasia.com The Controlled Environment Cleaning Specialists If it’s Mission Critical, It’s Got to be Data Clean!
Enter the password to open this PDF file:
-
-
-
-
-
-
-
-
-
-
-
-