1 two NUMPAGES Huawei H19-134_V1.0-ENU Exam HCSP-Presales-Data Center Facility (Power) V1.0 https://www.passquestion.com/h19-134_v1-0-enu.html 35% OFF on All, Including H19-134_V1.0-ENU Questions and Answers P ass H19-134_V1.0-ENU Exam with PassQuestion H19-134_V1.0-ENU questions and answers in the first attempt. https://www.passquestion.com/ 2 two NUMPAGES 1. What is the channel width of Huawei FusionModule2000? A. 1000mm B. 1100mm C. 1200mm D. 1300mm Answer: C 2. What is the seismic resistance rating of the Huawei Fusionmodule2000 IT cabinet? A. 7 B. 8 C. 9 Answer: C 3. The rated voltage of a single cell in a VRLA battery is not (). A. 12V B. 6V C. 2V D. 1V Answer: C 4. The NetCoL5000-A042H full-cabinet row-level air-cooled inverter precision air conditioner's light-load dehumidification function supports stable dehumidification under the lowest () load, which can solve the problem of frequent start-stop and failure to dehumidify in low-load, high-humidity environments, reducing the risk of condensation in the computer room. A. 0.05 B. 0.1 C. 0.15 D. 0.2 Answer: B 5. What configuration methods does the FusionModule800 UPS support? A. N/2N B. N/N+1/2N C. N/N+1 Answer: B 6. FusionModule1000A V2R3 version 40 - foot IT solution with N+X redundancy, featuring IBATTWERY configuration; how many IT racks can it provide? A. 5 B. 6 C. 7 D. 8 E. 9 Answer: C 3 two NUMPAGES 7. The power supply architecture adopted by the new row-level half-cabinet chilled water system is (). A. Single -circuit power supply B. Dual power supply C. Both A and B are correct. D. Other Answer: C 8. Which of the following humidification methods has the lowest energy consumption? A. Humidification of wet film B. Electrode humidification C. Infrared humidification Answer: A 9. Protection level of PDU8000 precision distribution cabinet (). A. IP20 B. IP21 C. IP30 D. IP40 Answer: A 10. The energy-saving effect of Huawei's iCooling is ()%. A. 15% B. 10% C. 8% D. 5% Answer: A 11. What is the maximum power consumption of the IT cabinets for FusionModule500 and FusionModule800? A. 3KVA B. 9KVA C. 7KVA D. 5KVA Answer: C 12. When configuring temperature control products, if the project site temperature is between -10 and 30 degrees Celsius, which of the following operating conditions should be preferred? A. Wide temperature range (-40-55 degrees Celsius) B. T1 (-20 to 45 degrees Celsius) C. T3 (-20 to 55 degrees Celsius) D. Extremely low temperatures (-40 to 45 degrees Celsius) Answer: B 4 two NUMPAGES 13. In which of the following regions does the AHU solution perform the worst? A. Xinjiang B. Beijing C. Harbin D. Hainan Answer: D 14. What sensor does the FusionModule2000 use to detect if the air conditioner is leaking water? A. Multifunctional sensor B. Infrared sensor C. Temperature sensor D. Water immersion sensor Answer: D 15. Which features are optional in the typical configuration of FusionModule500? A. pad, SMS alarm, video, mobile phone B. Pad, SMS alarm, video, water immersion, smoke detector C. pad, SMS alarm, mobile phone D. SMS alarms, mobile app, water immersion alarms, door sensor alarms Answer: B 16. The UPS system is equipped with 32 12V batteries. The UPS's set float charge voltage is (). A. 432V B. 451V C. 540V D. 564V Answer: A 17. Firefighting measures that can be adopted for Class A computer rooms include (). A. Gas fire suppression system B. Fine water mist fire suppression system C. Automatic sprinkler system D. All of the above Answer: A 18. The output power factor of UPS2000-A-(1K-3K) is (). A. 0.7 B. 0.8 C. 0.9 D. 0.99 Answer: B 19. Which of the following UPS systems does not have a neutral line? A. UPS5000-H 5 two NUMPAGES B. UPS5000-E C. galaxy5000 D. APM150 Answer: A 20. The operating interface of the UPS2000-G 6-20k main unit is (), which can display the system status in real time. A. LED B. LCD C. Touchscreen D. Remote network management Answer: B 21. Considering low UPS system load conditions, the UPS5000-E is designed with an intelligent sleep function. This function can improve the system load rate and maintain efficient system operation. When the UPS5000E is in intelligent sleep mode, how many power modules are redundant? A. 2 B. 1 Answer: B 22. What is the static load (in kg) of the FusionModule200 cabinet? A. 1500 B. 1800 C. 2000 D. 2400 Answer: D 23. Which of the following descriptions of the iMiManager feature in FusionModule2000 v3.0 is incorrect? A. Supports automatic asset allocation B. When listing a server, the optimal server location can be recommended. C. Can display capacity data such as space, power distribution, and cooling. D. All of the above Answer: D 24. When selecting both the expansion dry contact card and the backflow protection card for the UPS5000-E, which of the following options should also be selected? A. ECM extension frame B. IP21 Components C. Dry contact card socket Answer: A 25. What are the supported incoming line methods for the UPS5000-A-400/500K? A. Bottom line B. Upward line 6 two NUMPAGES C. Compatible with both top and bottom entry lines Answer: C 26. The humidifier type used in the NetCol5000-C032H intelligent temperature control product for chilled water is (). A. Electrode B. Infrared C. Wet film D. Ultrasound Answer: C 27. The UPS5000-E can easily realize a 2N power supply system by simply selecting (), and the operation is simple and convenient. A. BSC cable B. Synchronization Controller C. BSC Control Board D. Parallel card Answer: A 28. Which of the following descriptions about the reliability of the NetCol5000-C row-level air conditioner is incorrect? A. It adopts dual power supply, and the two power supplies use an automatic switching mode. B. Large data centers such as those of telecom operators and large corporate headquarters prefer this type of air conditioner. C. More small and medium-sized enterprises are adopting the Netcp15000-A air conditioner with multi-fan air supply: online maintenance is possible. D. Cannot be used in scenarios without raised floors, because condensate drainage cannot be connected to pipes. Answer: D 29. What power input methods does the FusionModule800 support? A. Single-path or dual-path B. Dual-path C. Single path Answer: A 30. What is the lowest outdoor ambient temperature that the FusionModule800 air conditioner can support? A. -20 degrees Celsius B. -40 degrees Celsius C. 0 degrees Celsius Answer: B 7 two NUMPAGES 31. Which of the following descriptions of the eLight feature, the smart module status indicator in FusionModule2000 v3.0, is correct? A. The eLight door frame indicator light is merely for decorative purposes and to enhance the ambiance. B. The eLight door frame indicator light can be linked to alarm status. C. The door frame indicator light eLight provides modular lighting functionality. D. None of the above are correct. Answer: B 32. When the length of a rack () arranged in a row exceeds the length of two channels, additional channels should be added () between the two channels. Channels should be provided at both ends. When the distance between two channels exceeds the length of two channels, additional channels should be added directly between the two channels. A. 6m, 15m B. 6m, 20m C. 8m, 15m D. 8m, 20m Answer: A 33. The UPS5000-E features a wide voltage and frequency input range, making it suitable for harsh power grid environments and extending battery life. What is the full-load input voltage range of the UPS5000-E? under full load? A. 138-485V B. 305-485V C. 105-485V Answer: A 34. What are the maximum number of cabinets within the FusionModule500 and FusionModule800 modules respectively? A. 10, 6 B. 6, 2 C. 9, 5 D. 4, 10 Answer: D 35. Which of the following product models is similar in characteristics to the UPS5000 series modular UPS? A. Hipulse-u B. 8O-NET C. NXr D. APM Answer: D 36. Which of the following features is a standard feature of the NETCOL8000-C air conditioner? 8 two NUMPAGES A. Dual power supply B. Water immersion sensor C. G4 grade filter D. Humidification function Answer: C 37. For a UPS5000-E 100kVA, which of the following input switches is most suitable? A. 125A B. 80A C. 160A D. 200A Answer: D 38. The UPS500-A-400/500K can support a maximum of () parallel operation, and has good scalability. A. 4 B. 2 C. 3 D. 6 Answer: A 39. Assume a battery specification states a discharge power of 400W@1.67V@15min. If the system requirement is 1400W, then the number of battery packs selected is (). A. 3 B. 4 C. 5 Answer: B 40. UPS5000-A/E models above 400KVA are available in standard and enhanced versions. The standard version comes standard with a () disconnect switch. A. Main Input B. Bypass Input C. Repair D. Output Answer: C 41. When the NetEco management system intervenes in third-party devices surrounding the micro-module, what monitoring hardware is typically used for access? A. ECC500 data acquisition unit B. ECC800 data acquisition unit C. Serial port server D. None of the above Answer: B