H12-425_V2.0-ENU P ractice Exam HCIP-Data Center Facility Deployment V2.0 https://www.passquestion.com/H12-425_V2.0-ENU.html Download valid H12-425_V2.0-ENU Practice Exam From PassQuestion 1. Which type of compressor is used in new room-level air cooling? A. AC inverter compressor B. Digital scroll compressor C. Fixed frequency compressor D. DC inverter compressor Answer: B Download valid H12-425_V2.0-ENU Practice Exam From PassQuestion 2. Which of the following is a component of Huawei's indirect evaporative cooling system? (Multiple Choice) A. Indirect heat exchange system B. Mechanical supplemental cooling system C. Sprinkler System D. Electronic control system Answer: ABCD Download valid H12-425_V2.0-ENU Practice Exam From PassQuestion 3. Which of the following resources can be managed by the capacity management function of the Huawei NetEco management system? (Multiple choice) A. Cabinet space B. Distribution Capacity C. Cooling capacity D. Room area Answer: ABC Download valid H12-425_V2.0-ENU Practice Exam From PassQuestion 4. What are the alarm management functions supported by the ECC800? (Multiple choice) A. View historical alarms B. Filter alerts C. Alarm data export D. Alarm parameter setting Answer: ABCD Download valid H12-425_V2.0-ENU Practice Exam From PassQuestion 5. What can users do through the ECC800WEB interface? (Multiple choice) A. Real-time monitoring of equipment status B. Query version information C. Export historical data D. Software Upgrade Answer: ABCD Download valid H12-425_V2.0-ENU Practice Exam From PassQuestion 6. What are the functions provided by the Huawei surveillance system NETECO? (Multiple choice) A. Provide 2D, 3D data center view display B. Support modular/cabinet-level view display C. Support system power distribution view display D. Only provide view creation tools to facilitate and quickly configure views Answer: ABCD Download valid H12-425_V2.0-ENU Practice Exam From PassQuestion 7. What are the steps to maintain the electrode humidifier when the NETCOL5000-A removes the air conditioner humidifier? (Multiple choice) A. Disconnect the water supply valve drain valve wiring B. Remove the drain and drain valve assembly C. Remove and clean the water supply valve D. Replace hard and brittle hoses and flush drains thoroughly Answer: ABCD Download valid H12-425_V2.0-ENU Practice Exam From PassQuestion 8. What are the factors that affect the service life of the battery? (Multiple choice) A. Temperature B. Cycle times C. Depth of Discharge D. Rated capacity Answer: ABC Download valid H12-425_V2.0-ENU Practice Exam From PassQuestion 9. What are the possible reasons for the failure of the humidification function of the NETCOL5000-A air conditioner? (Multiple choice) A. The indoor temperature is low B. Humidifier damage C. Humidifier circuit is not closed D. The outdoor unit is not running Answer: BCD Download valid H12-425_V2.0-ENU Practice Exam From PassQuestion 10. After the UPS5000-E is installed, what are the key points for the first power-on inspection? (Multiple choice) A. Whether the mechanical installation and cable installation are tight B. Input and output without short circuit C. AC input phase sequence is correct D. Battery wiring is correct Answer: ABCD