EN C O N T E N T S S AFETY PR E C A UTIONS NAME OF P A R T S REM O TE C ONT R OL OPER A TION IN S TRU C TIONS IN S TRU C TIONS F OR SE R VICING(R32) IN S T ALL A TION PR E C A UTIONS INDOOR UNIT IN S T ALL A TION OUTDOOR UNIT IN S T ALL A TION T E S T OPER A TION MAINTENANCE T R OUBL E SHO O TING ........................................................................................................................37 ..............................................................................................34 ..................................................................................................23 ............................................................................................................................4 ...............................................................................................................1 .................................................................................................22 ............................................................................................................................38 ....................................................................................15 ...................................................................................................................40 DDISPOSAL GUIDELINE (European) ..........................................................................................41 .....................................................................................................14 .......................................................................................................................6 * The design and specifi c a tions a r e subject t o chan g e without prior notice f or p r oduct imp r o v eme n t. Consult with the sales a g ency or manu f actu r er f or d e t ails. * The shape and position of bu t t ons and indi c a t o r s m a y v ary ac c o r ding t o the model, but their function a r e the same. EN Accessories Indoor Unit Ou t door Unit c o n t r o l l e r Rem o t e A A A b a t t e r y S c r e w U s e r m a n u a l F r e s h a i r f i l t e r E x t e n s i o n J o i n t M e t a l s t r a p s u p p o r t e r P l a s t i c a n c h o r s D r a i n a g e h o s e S e a l a n t I n s u l a t i n g t a p e X 2 X 2 X 6 X 6 X 2 X 4 n u t s ( o p t i o n a l ) R e f r i g e r an t p i p e F r e s h a i r p i p e X 1 X 2 W a l l s l e e v e c o v e r ( o p t i o n a l ) I n s u l a t i o n p i p e D r a i n a g e j o i n t ( s o m e m o d e l s d o n o t h a v e ) Internal circulation ( s o m e m o d e l s d o n o t h a v e ) X 2 EN 1 1. Read this guide b e f o r e in s t alling and using the appliance. 2. During the in s t all a tion of the indoor and ou t door units, access t o the w orking a r ea should be f orbidden t o child r en. Un f o r eseeable accide n ts c ould happen. 3. Ma k e su r e th a t the base of the ou t door unit is firmly fi x ed. 4. Check th a t air c annot e n t er the r e fri g e r a n t s y s t em and check f or r e fri g e r a n t lea k s when moving the air c onditione r 5. Carry out a t e s t c y cle a f t er in s t alling the air c onditioner and r e c o r d the ope r a ting d a t a. 6. P r o t ect the indoor unit with a fuse of sui t able c apacity f or the m a ximum input cur r e n t or with another o v erload p r o t ection device. 7. Ensu r e th a t the mains v ol t a g e c or r esponds t o th a t s t amped on the r a ting pl a t e. K eep the swi t ch or po w er plug clean. Insert the po w er plug c or r ectly and firmly i n t o the soc k e t, the r eby a v oiding the risk of electric shock or fi r e due t o insu f ficie n t c o n t act. 8. Check th a t the soc k e t is sui t able f or the plug , otherwise h a v e the soc k e t chan g ed. 9. The appliance mu s t be fi t t ed with means f or dis c onnection f r om the supply mains h a ving a c o n t act sepa r a tion in all poles th a t p r ovide full dis c onnection under o v er v ol t a g e c a t e g ory III c onditions, and these means mu s t be in c orpo r a t ed in the fi x ed wiring in ac c o r dance with the wiring rules. 10. The air c onditioner mu s t be in s t alled by p r o f essional or qualified pe r sons. 11. Do not in s t all the appliance a t a di s t ance of less than 50 cm f r om inflammable sub s t ances (al c ohol, e t c.) Or f r om p r essuri z ed c o n t aine r s (e g. sp r a y c ans). 12. If the appliance is used in a r eas without the possibility of v e n til a tion, p r e c autions mu s t be t a k en t o p r e v e n t a n y lea k s of r e fri g e r a n t g as f r om r emaining in the e n vi r onme n t and c r e a ting a dan g er of fi r e. 13. The pac k aging m a t erials a r e r ec y clable and should be disposed of in the sepa r a t e w a s t e bins. T a k e the air c onditioner a t the end of its us e ful li f e t o a special w a s t e c ollection ce n t er f or disposal. 14. Only use the air c onditioner as in s truc t ed in this bookl e t. These in s tructions a r e not i n t ended t o c o v er e v ery possible c ondition and situ a tion. As with a n y electri c al household appliance, c ommon sense and c aution a r e the r e f o r e al w a y s r e c ommended f or in s t all a tion, ope r a tion and mai n t enance. 15. The appliance mu s t be in s t alled in ac c o r dance with appli c able n a tional r egul a tions. 16. B e f o r e accessing the t erminals, all the po w er ci r cuits mu s t be dis c onnec t ed f r om the po w er suppl y 17. The appliance shall be in s t alled in ac c o r dance with n a tional wiring r egul a tions. 18. This appliance c an be used by child r en a g ed f r om 8 y ea r s and abo v e and pe r sons with r educed p h y si c al, sensory or me n t al c apabilities or la c k of e xperience and knowled g e if th e y h a v e been gi v en supe r vision or in s truction c oncerning use of the appliance in a s a f e w a y and unde r s t and the ha z a r ds i n v ol v ed. Child r en shall not pl a y with the appliance. Cleaning and user mai n t enance shall not be made by child r en without supe r vision. S AFETY RUL E S AND R E C OMMEN D A TIONS F OR THE IN S T ALLER S AFETY PR E C A UTIONS EN 19. Do not try t o in s t all the c onditioner alone, al w a y s c o n t act speciali z ed t echni c al pe r sonnel. 20. Cleaning and mai n t enance mu s t be c arried out by speciali z ed t echni c al pe r sonnel. In a n y c ase dis c onnect the appliance f r om the mains elec t r i city supply b e f o r e c arrying out a n y cleaning or mai n t enance. 21. Ensu r e th a t the mains v ol t a g e c or r esponds t o th a t s t amped on the r a ting pl a t e. K eep the swi t ch or po w er plug clean. Insert the po w er plug c or r ectly and firmly i n t o the soc k e t, the r eby a v oiding the risk of electric shock or fi r e due t o insu f ficie n t c o n t act. 22. Do not pull out the plug t o swi t ch o f f the appliance when it is in ope r a tion, since this c ould c r e a t e a spark and c ause a fi r e, e t c. 23. This appliance has been made f or air c onditioning dome s tic e n vi r onme n ts and mu s t not be used f or a n y other purpose, such as f or drying clothes, c ooling f ood, e t c. 24. Al w a y s use the appliance with the air fil t er mou n t ed. The use of the c onditioner without air fil t er c ould c ause an e x cessi v e accumul a tion of du s t or w a s t e on the inner parts of the device with possible subseque n t f ailu r es. 25. The user is r esponsible f or h a ving the appli a nce in s t alled by a qualified t echnician, who mu s t check th a t it is earth in ac c o r dance with cur r e n t legisl a tion and insert a thermos magn e tic ci r cuit b r ea k e r 26. The b a t t eries in the r emo t e c o n t r oller mu s t be r ec y cled or disposed of p r operl y F or disposal of sc r ap b a t t eries, please dis c a r d the b a t t eries as sor t ed municipal w a s t e a t the accessible c ollection poi n t. 27. Ne v er r emain di r ectly e xposed t o the flow of c old air f or a long time. The di r ect and p r olon g ed e xposition t o c old air c ould be dan g e r ous f or y our health. P articular c a r e should be t a k en in the r ooms whe r e the r e a r e child r en, old or sick people. 28. If the appliance gi v es o f f smo k e or the r e is a smell of burnin g , immedi a t ely cut o f f the po w er supply and c o n t act the Se r vice Ce n t e r 29. The p r olon g ed use of the device in such c onditions c ould c ause fi r e or elect r ocution. 30. H a v e r epai r s c arried out only by an authori s ed Se r vice Ce n t r a of the manu f actu r e r . In c or r ect r epair c ould e xpose the user t o the risk of electric shock, e t c. 31. Unhook the au t om a tic swi t ch if y ou f o r esee not t o use the device f or a long time. The airflow di r ection mu s t be p r operly adju s t ed. 32. The flaps mu s t be di r ec t ed dow n w a r ds in the he a ting mode and up w a r ds in the c ooling mode. 33. Ensu r e th a t the appliance is dis c onnec t ed f r om the po w er supply when it will r emain inope r a ti v e f or a long period and b e f o r e c arrying out a n y cleaning or mai n t enance. 34. Selecting the mo s t sui t able t empe r a tu r e c an p r e v e n t dama g e t o the appliance. 2 S AFETY RUL E S AND R E C OMMEN D A TIONS F OR THE IN S T ALLER S AFETY PR E C A UTIONS EN 1. Do not bend, tug or c omp r ess the po w er c o r d since this c ould dama g e it. Electri c al shoc k s or fi r e a r e p r obably due t o a dama g ed po w er c o r d. Speciali z ed t echni c al pe r sonnel only mu s t r eplace a dama g ed po w er c o r d. 2. Do not use e x t ensions or g ang modules. 3. Do not t ouch the appliance when ba r e f oot or parts of the body a r e w e t or damp. 4. Do not ob s truct the air inl e t or outl e t of the indoor or the ou t door unit. The ob s truction of these openings c auses a r eduction in the ope r a ti v e e f ficiency of the c onditioner with possible c onseque n t f ailu r es or dama g es. 5. In no w a y al t er the cha r ac t eri s tics of the appliance. 6. Do not in s t all the appliance in e n vi r onme n ts whe r e the air c ould c o n t ain g as, oil or sulphur or near sou r ces of he a t. 7. This appliance is not i n t ended f or use by pe r sons (including child r en ) with r educed p h y si c al, sensory or me n t al c apabilities, or lack of e xperience and knowled g e, unless th e y h a v e been gi v en supe r vision or in s truction c oncerning use of the appliance by a pe r son r esponsible f or their s a f e t y 8. Do not climb o n t o or place a n y he a vy or hot objects on t op of the appliance. 9. Do not le a v e windo w s or doo r s open f or long when the air c onditioner is ope r a ting. 10. Do not di r ect the airflow o n t o pla n ts or animals. 11. Along di r ect e xposition t o the flow of c old air of the c onditioner c ould h a v e ne g a ti v e e f f ects on pla n ts and animals. 12. Do not put the c onditioner in c o n t act with w a t e r . The electri c al insul a tion c ould be dama g ed and thus c ausing elect r ocution. 13. Do not climb o n t o or place a n y objects on the ou t door unit. 14. Ne v er insert a s tick or similar object i n t o the appliance. It c ould c ause injur y 15. Child r en should be supe r vised t o ensu r e th a t th e y do not pl a y with the appliance. If the supply c o r d is dama g ed, it mu s t be r eplaced by the manu f actu r e r , its se r vice a g e n t or similarly qualified pe r sons in o r der t o a v oid a ha z a r d. 3 S AFETY RUL E S AND P R OHIBITIONS S AFETY PR E C A UTIONS EN Indoor Unit Not e : This figure shown may be different from the actual object. Ple ase take the latter as the standard. With the protective cover removed Liquid valve Gas valve (Low pressure valve) (High pressure valve) 4 NAME OF PARTS Mou nting p l a t e Air filter Outdoor Unit F r ont panel Air deflector and flap Air outlet R e frigerant c o n n e c t i n g p i p e Air inlet Drainage pipe Connection wiring Valve protective cover Air outlet Fresh air pipe Protection net EN Indoor Displ a y The shape and position of s wi t ches and indicato r s m a y be diffe r e n t ac c o r ding t o the model, but their function is the same. 4 1 2 3 Lights up when Fresh Air function is on. Operation indicator/Air quality status indicator (if TVOC function is available When the life of the filter element is less than 20%, shut down and when the fresh air is turned off, the panel displays the life value of the filter element 5 NAME OF P A R T S Lights up when Wi-Fi is on. No t e: No LED Function The air c onditioner au t omati c ally adj u s ts the displ a y brig h tness and buz z er sound ac c o r ding t o the ambie n t li g h t i n t ensity . When the air c ondition e r d e t ects th a t the ambie n t li g h t is w eak for a period of time, it will automatically turns off the displ a y temporarily. If t h e r e is a r emo t e c o n t r ol or APP ope r ation, the displ a y will disp l a y a t a low bri g h tness f or a short time, and the buz z er will r espond a t a lo w er v olum e ; When the air conditioner d e t ects th a t the ambie n t li g h t is s t r ong f or a period of time, e xit the abo v e ope r ation. 2 4 1 3 Indicator for Timer, temperature and Error codes. EN REM O TE C ONT R OL 6 R emo t e c o n t r ol DISPL A Y The displ a y and some func�ons of the r emo t e c o n t r ol m a y v ary ac c o r ding t o the model. S ymbols Cooling Mode Dry Mode F an only Mode He a �ng Mode F an speed: Au t o/ low/ low-mid/ mid/ mid-high/ high TURBO func�on Mu t e func�on Up-down au t o swing T empe r a tu r e indi cat or Meaning L e �-rig h t au t o swing SLEEP func�on Timer B a � ery indi c at or Au t o Mode Health func�on I FEEL func�on E C O Mode 8 he a �ng func�on o C Signal indi c at or Ge n tle wind Child-Lock Displ a y ON/OFF No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 A n �-Mildew Self-Clean func�on GEN func�on 26 F r esh air EN REM O TE C ONT R OL 7 The shape and posi�on of bu � ons and indi c at o r s m a y v ary ac c o r ding t o the model, but their func�on is the same. The displ a y and some func�ons of the r emo t e c o n t r ol m a y v ary ac c o r ding t o the model. The unit c onfirms the c or r ect r ecep�on of each bu � on with the beep. No. Bu � on Func�on T o select the mode of ope r a �on ( A U T O , C OO L , D R Y , F AN, H E A T). T o ac� v a t e/deac� v a t e the TURBO func�on. T o dec r ease t empe r a tu r e, or Timer s e �ng hou r s. T o inc r ease t empe r a tu r e, or Timer s e �ng hou r s. T o turn on / o ff the air c ondi�oner . T o select the f an speed of au t o/mu t e/low/low-mid/mid/mid-high/high/turbo. 8 11 6 7 9 MODE TURBO 1 2 3 4 F AN 5 T o ac� v a t e/deac� v a t e the E C O func�on. E C O T o s e t the �me f or �mer on / o ff TIMER T o swi t ch-on / o ff the func�on SLEE P SLEEP 10 T o swi t ch-on / o ff the LED displ a y DISPL A Y T o s t op or s t art hori z o n t al lou v er mo v eme n t or s e t the desi r ed up/down air flow di r ec�on. 12 13 T o swi t ch-on / o ff the I FEEL func�on. I FEEL 14 T o swi t ch-on / o ff the MUTE func�on. MUTE Long p r ess t o ac� v a t e/deac� v a t e the GEN func�on (depending on models). T o s t op or s t art hori z o n t al lou v er mo v eme n t or s e t the desi r ed l e �/rig h t air flow di r ec�on. 15 16 T o ac� v a t e/deac� v a t e the CHILD- L OCK func�on. MODE + TIMER 17 T o ac� v a t e/deac� v a t e the SELF-CL E AN func�on when swi t ch OF F 18 T o ac� v a t e/deac� v a t e the GENTLE WIND func�on (depending on models). T o ac� v a t e/deac� v a t e the H E A L TH func�on (depending on models). H E A L TH Long p r ess t o ac� v a t e/deac� v a t e the 8 he a �ng func�on (depending on models). o C T o ac� v a t e/deac� v a t e the F r esh Air func�on and select the f an speed. FR E SH AIR GENTLE WIND EN REM O TE C ONT R OL 8 R eplaceme n t of B a � eries R emo v e the b a � ery c o v er pl at e f r om the r ear of the r emo t e c o n t r ol, by sliding it in di r ec�on as the ar r o w In s t all the b a � eries ac c o r ding the di r ec�on (+ and -)shown on the R emo t e Co n t r ol. R ein s t all the b a � ery c o v er by sliding it i n t o place. Use 2 pieces L R O3 AAA (1.5V) b a � eries. Do not use r echa r g eable b a � eries. R eplace the old b a � eries with new ones of the same type when the displ a y is no lon g er legible. Do not dispose b a � eries as unsor t ed municipal w a s t e. Collec�on of such w a s t e sepa r a t ely f or special t r e a tme n t is necessar y No t e: 1 Di r ect the r emo t e c o n t r ol t o w a r d the Air c ondi�one r 2 Check th a t the r e a r e no objects b e t w een the r emo t e c o n t r ol and the Signal r ecep t or in the indoor unit. 3 Ne v er le a v e the r emo t e c o n t r ol e xposed t o the r a y s of the sun. 4 K eep the r emo t e c o n t r ol a t a di s t ance of a t lea s t 1m f r om the t elevision or other electri c al appliances. F or some models of the r emo t e c o n t r olle r , y ou c an p r og r am the t empe r a tu r e displ a y b e t w een o o C and F 1 P r ess and hold the TURBO bu � on o v er 5 se c onds t o g e t i nt o the chan g e mode; o o 2 P r ess and hold the TURBO bu � on, u n �l it swi t ch t o C and F; 3 Then r elease the p r essing and w ait f or 5 se c onds, the func�on will be selec t ed. EN 9 REM O TE C ONT R OL C OOLING MODE H E A TING MODE The c ooling func�on allo w s the air c ondi�oner t o c ool the r oom and r educe Air humidity a t the same �me. H E A T The he a �ng func�on allo w s the air c ondi�oner t o he a t the r oom. T o ac� v a t e the c ooling func�on ( C OOL), p r ess the MODE bu � on u n �l the s ymbol appea r s on the displ a y With the bu � on or s e t a t empe r a tu r e lo w er than th a t of the r oom. T o ac� v a t e the he a �ng func�on (H E A T), p r ess the MODE bu � on u n �l the s ymbol appea r s on the displ a y With the bu � on or s e t a t empe r a tu r e higher than th a t of the r oom. In H E A TING ope r a �on, the appliance c an au t om a � c ally ac� v a t e a d e f r o s t c y cle, which is esse n �al t o clean the f r o s t on the c ondenser so as t o r e c o v er its he a t e x chan g e func�on. This p r ocedu r e usually la s ts f or 2-10 minu t es. During d e f r o s �n g , indoor unit f an s t op ope r a �on. A � er d e f r o s �n g , it r esumes t o H E A TING mode au t om a � c all y C OO L ( F or North Ameri c an mar k e t) If necessar y , y ou c an p r ess DISPLAY bu � on 10 �mes within 8 se c onds under he a �ng mode t o s t art the f o r ced d e f r o s �ng. It will d e f r o s t the ou t door ice much f a s t e r D R Y MODE This func�on r educes the humidity of the air t o ma k e the r oom mo r e c o m f or t able. D R Y T o s e t the D R Y mode, P r ess MODE u n �l appea r s in the displ a y . An au t om a �c func�on of p r e-s e �ng is ac� v a t ed. F AN MODE (Not F AN bu � on) F A N F an mode, air v e n �l a �on onl y T o s e t the F AN mode, p r ess MODE u n �l appea r s on the displ a y A U T O MODE Au t om a �c mode. A U T O T o s e t the A U T O mode, p r ess MODE u n �l appea r s on the displ a y In A U T O mode the run mode will be s e t au t om a � c ally ac c o r ding t o the r oom t empe r a tu r e. F AN SPEED func�on ( F AN bu � on) F AN Chan g e the ope r a �ng f an speed. P r ess F AN bu � on t o s e t the running f an speed, it c an be s e t t o A U T O/ MUTE/ L O W/ L O W-MID / MID/ MID-HIGH/ HIGH/ TURBO speed ci r cularl y Child-Lock func�on 1 Long p r ess MODE and TIMER bu � on t o g e ther t o ac� v e this func�on, and do it a g ain t o deac� v a t e this func�on. 2 Under this func�on, no single bu � on will ac� v e. (Flash) EN 1 0 REM O TE C ONT R OL T o au t om a �c swi t ch on the appliance. TIMER func�on ---- TIMER OFF T o au t om a �c swi t ch o ff the appliance. When the unit is swi t ch-o ff , y ou c an s e t the TIMER ON. T o s e t the �me of au t om a �c swi t ch-on as below: When the unit is swi t ch-on, y ou c an s e t the TIMER OF F T o s e t the �me of au t om a �c swi t ch-o ff , as below: 1 Confirm the appliance is ON. 2 P r ess the TIMER bu � on a t fi r s t �me t o s e t the swi t ch-o ff P r ess or t o s e t the needed �me r 3 P r ess TIMER bu � on a t the se c ond �me t o c onfirm. CANCEL it by p r ess TIMER bu � on. No t e: All p r og r amming should be ope r a t ed within 5 se c onds, otherwise the se �ng will be c ancelled. TIMER TIMER TURBO func�on TURBO T o ac� v a t e turbo func�on, p r ess the TURBO bu � on, and will appear on the displ a y P r ess a g ain t o c ancel this func�on. In C OOL/ H E A T mode, when y ou select TURBO f e a tu r e, the appliance will turn t o quick C OOL or quick H E A T mode, and ope r a t e the highe s t f an speed t o blow s t r ong airflo w TIMER func�on ---- TIMER ON S WING func�on 1 P r ess TIMER bu � on fi r s t �me t o s e t the swi t ch-on, and will appear on the r emo t e displ a y and flashes. 2 P r ess or t o bu � on t o s e t desi r ed Timer-on �me. E ach �me y ou p r ess the bu � on, the �me inc r eases/dec r eases by half an hour b e t w een 0 and 10 hou r s and by one b e t w een 10 and 24 hou r s. 3 P r ess TIMER bu � on se c ond �me t o c onfirm. 4 A � er Timer-on s e �n g , s e t the needed mode (Cool/ He a t/ Au t o/ F an/ Dry), by p r ess the MODE bu � on. And s e t the needed f an speed, by p r ess F AN bu � on. And p r ess or t o s e t the needed ope r a �on t empe r a tu r e. CANCEL it by p r ess TIMER bu � on. Ne v er posi�on Flaps manuall y , the deli c a t e mechanism mig h t seriously dama g ed! Ne v er put fin g e r s, s �c k s or other objects i n t o the air inl e t or outl e t v e n ts. Such accide n t al c o n t act with li v e parts mig h t c ause un f o r eseeable dama g e or injur y 1 P r ess the bu � on S WING t o ac� v a t e the lou v e r , 1.1 P r ess t o ac� v a t e the hori z o n t al flaps t o swing f r om up t o down, the will appear on the r emo t e displ a y 1.2 P r ess t o ac� v e the v er� c al d e flec t o r s t o swing f r om l e � t o rig h t, the will appear on the r emo t e displ a y 1.3 Do it a g ain t o s t op the swing mo v eme n t a t the cur r e n t angle. 2 If the v er� c al d e flec t o r s a r e posi�oned manually which placed under the flaps, th e y allow t o mo v e the air flow di r ect t o rig h t w a r d or l e � w a r d. 3.Long p r ess or o v er 3 se c onds t o select mo r e angles of the airflow di r ec�on. EN 1 1 REM O TE C ONT R OL MUTE func�on E C O func�on MUTE 1 P r ess MUTE bu � on t o ac� v e this func�on, and will appea r s on the r emo t e displ a y Do it a g ain t o deac� v a t e this func�on. 2 When the MUTE func�on runs, the r emo t e c o n t r oller will displ a y the au t o f an speed, and the indoor unit will ope r a t e a t lo w e s t f an speed t o be qui e t f eeling. 3 When p r ess F AN/ TURBO/ SLEEP bu � on, the MUTE func�on will be c ancel. MUTE func�on c an not be ac� v a t ed under dry mode. I FEEL func�on (Op�onal) P r ess I FEEL bu � on t o ac� v e the func�on, the will appear on the r emo t e displ a y Do it a g ain t o deac� v a t e this func�on. This func�on enables the r emo t e c o n t r ol t o measu r e the t empe r a tu r e a t its cur r e n t lo c a �on, and send this signal t o the air c ondi�oner t o op�mi z e the t empe r a tu r e a r ound y ou and ensu r e the c o m f ort. I FEEL DISPL A Y func�on (Indoor displ a y) DISPL A Y S wi t ch ON/OFF the LED displ a y on panel. P r ess DISPL A Y bu � on t o swi t ch o ff the LED displ a y on the panel. P r ess a g ain t o swi t ch on the LED displ a y E C O In this mode the appliance au t om a � c ally s e ts the ope r a �on t o s a v e ene r g y P r ess the E C O bu � on, the appea r s on the displ a y , and the appliance will run in E C O mode. P r ess a g ain t o c ancel it. No t e: The E C O func�on is av ailable in both C OOLING and H E A TING modes. SLEEP func�on SLEEP P r e-s e �ng au t om a �c ope r a �ng p r og r am. A � er 10 hou r s running in sleep mode, the air c ondi�oner will chan g e t o the p r evious s e �ng mode. P r ess SLEEP bu � on t o ac� v a t e the SLEEP func�on, and appea r s on the displ a y P r ess a g ain t o c ancel this func�on. GEN func�on (Op�onal) 1 T urn on the indoor unit a t fi r s t, and long p r ess MUTE bu � on 3 se c onds t o ac� v e, and do it a g ain t o deac� v a t e this func�on. 2 Under this func�on, short p r ess MUTE bu � on t o select the Gene r al type L3 - L2 - L1 - O F 3 Select OF and w ait 2 se c onds t o e xit it. R es e t Wi-Fi 1.M e thod 1: P r ess bu � on DISPL A Y 6 �mes in 8 se c onds. 2.M e thod 2: Long p r ess MODE and o v er 3 se c onds. Y ou will hear 2 beeps and CF or AP will show on the indoor displ a y a � er the ope r a �on. EN 1 2 REM O TE C ONT R OL SELF-CL E AN func�on (Op�onal) Ge n tle Wind func�on (Op�onal) 1 This func�on helps c arry a w a y the accumul a t ed dirt, bac t eria, e t c f r om the indoor e v apo r a t o r 2 This func�on will run about 30 minu t es, and it will r e turn t o the p r e-s e �ng mode. Y ou c an p r ess bu � on t o c ancel this func�on during the p r ocess. Y ou will hear 2 beeps when it's finished or c ancelled. It's normal if the r e is some noise during this func�on p r ocess, as pla s �c m a t erials e xpand with he a t and c o n t r act with c old. Health func�on (Op�onal) 8 he a �ng func�on (Op�onal) o C 1 Long p r ess E C O bu � on o v er 3 se c onds t o ac� v e this func�on, and ( ) will appear on o o 8 C 4 6 F the r emo t e displ a y Do it a g ain t o deac� v a t e this func�on. 2 This func�on will au t o s t art the he a �ng mode o when the r oom t empe r a tu r e is lo w er than 8 C o (4 6 F), and it will r e turn t o s t andby if the o o t empe r a tu r e r eaches 9 C (4 8 F). o 3 If the r oom t empe r a tu r e is higher than 1 8 C o (6 4 F), the appliance will c ancel this func�on au t om a � c all y Indoor unit Ou t door unit o o T emp < 8 6 F (3 0 C) o o o o 4 1 F ( 5 C) < T emp < 8 6 F (3 0 C) W e su g g e s t ope r a �ng this func�on a t the f ollowing ambie n t c ondi�ons t o a v oid cer t ain s a f e ty p r o t ec�on f e a tu r es. It's su g g e st ed t o u�li z e this func�on e v ery 3 mo n ths. T o ac� v e this func�on, turn o ff the indoor unit a t fi r s t, then p r ess H E A L TH bu � on then y ou will hear a beep, A C will appear on the indoor LE D , and will appear on the r emo t e displ a y . 2 When the H E A L TH func�on is ini� a t ed, the U V C Lig h ts(depending on models) will be ene r gi z ed and running. 1 T urn on the indoor unit a t fi r s t, p r ess H E A L TH t o ac� v e this func�on, will appear on the displ a y Do it a g ain t o deac� v a t e it. F r esh Air func�on Co n �nue p r ess bu � on u n �l select y our desi r ed F r esh Air f an speed or deac� v a t e this func�on as ci r cul a �on Low-Mid-High-OFF , then loose bu � on. The f ollowing indi c a t or will appear on the displ a y: Au t o f an speed Low f an speed High f an speed Mid f an speed OFF (no indi c a t or) No t e: 1. This func ti on is a v ail a ble when in OF F /Hea ti ng Cooling / F an / Aut o mode. 2.The s y s t em ma y run aut oma �c ally the big dif bec ause of f er ence of t emper a tur e indoor and outside. be tw een FRE SH AIR 1. T urn on the indoor unit, and chang e t o C OOL mode, then pr ess GENTLE WIND but t on or t o ac�v e this func�on, will appear on the displa y Do it ag ain t o deac�v a t e it. 2. This func�on will aut o close the v er�c al flaps, and giv e y ou the c om f ort able g en tle wind f eeling. FRE SH AIR ( F l a s h ) This func�on will pump the fr esh air fr om outside t o inside 3.Long pressing the fresh air key for 5 seconds to reset the timing of the fresh air strainer. EN REM O TE C ONT R OL T V OC function (Optional) The d e t ection of T V OC is mainly aimed a t v arious v ol a tile o r g anic c ompounds, such as f ormalde h y de, ben z ene, pol y c y clic a r om a tic h y d r o c arbons, e t c., close t o perfume, t oil e t w a t e r , al c ohol, air f r eshen- e r s, e t c., will also lead t o an inc r ease in the d e t ec t ed T V OC c once n t r a tion. The T V OC sensor needs t o be initiali z ed e v ery time it is po w e r ed on, please w ait p a tie n tly f or about 10 minu t es. This function enable t o d e t ect some kinds of har m ful g ases in the r oom and displ a y the air quality s t a tus. If the unit is equipped with this function, when the unit is ope r a tion, it will displ a y the f ollowing indi c a t or s t a t es ac c o r ding t o the d e t ec t ed c oncen- t r a tion of di f f e r e n t har m ful g ases. 1 When the setting state of fresh air is blue, the air quality is better; Fresh air setting status displays orange when air qualityQuantity difference (Note: the air quality detection object is TVOC, such as polycyclic aromatic hydrocar-bons, benzene, formaldehyde, trichl-oroethylene,etc.). 2 All panel displ a y lig h ts including T V OC c an be turned o f f by p r essing the DISPL A Y button. 3 T urning on the F r esh Air function c an imp r o v e the indoor air qualit y , but when the ou t door air pollution is serious, it is r e c ommended t o turn o f f the F r esh Air function. 4.If the unit is not equipped with T V OC function, it will displ a y 100% blue when the machine is running and the c olor will not chan g e. Depending on the b r and or w orking principle of t h e t e s ting equipme n t, T V OC t e s ting r esults m a y v ar y 13 Excellent air quality Blue Yellow Good air quality Orange Poor air quality EN A t t em p t t o use the air c onditioner under the t empe r a tu r e b e y ond the specified r an g e m a y c ause the air c onditioner p r o t ection d e vice t o s t art and the air c onditioner m a y f ail t o ope r a t e. The r e f o r e, t r y t o use the air c onditioner in the f ollowing t empe r a tu r e c onditions. OPER A TION IN S TRU C TIONS 14 With the po w er supply c onnec t ed, r e s t art the air c onditioner a f t er shu t down, or s wi t ch it t o other mode during ope r a tion, and the air c onditioner p r o t ection d e vice will s t art. The c omp r essor will r esume ope r a tion a f t er 3 minu t es. Cha r ac t eri s tics of he a ting ope r a tion (appli c able t o He a ting pump) P r ehe a ting: When the he a ting function is enabled, the ind o or unit will t a k e 2~5 minu t es f or p r ehe a tin g , a f t er th a t the air c onditioner will s t art he a ting and blo w s w arm ai r D e f r o s ting: During he a tin g , when the ou t door unit f r o s t ed, the air c onditioner will enable the au t om a tic d e f r o s ting function t o imp r o v e the he a ting e f f ect. During d e f r o s tin g , the indoor and ou t door f ans s t op running. The air c onditioner will r esume he a ting au t om a ti c ally a f t er d e f r o s ting finish. I n v er t er air c onditioner: 0°C ~2 7 (3 2 ~8 0 ) °C °F °F Dry He a ting Cooling R oom t empe r a tu r e 1 7 32 °C (63 °F ~90 °F ) °C ~ Ou t door t empe r a tu r e T empe r a tu r e MODE - 2 0 °C ~ 2 4°C ( - 4 ~ 7 5 ) °F °F 1 5 ~5 0 (5 9 ~12 2 ) °C °C °F °F (Low t empe r a tu r e c ooling: -1 5 ~5 0 ( 5 ~12 2 )) °C °C °F °F EN INSTRUCTIONS FOR SERVICING(R32) 1. Check the information in this manual to find out the dimensions of space needed for proper installation of the device, including the minimum distances allowed compared to adjacent structures. 2 2. Appliance shall be installed, operated and stored in a room with a floor area larger than 4m . 3. The installation of pipe-work shall be kept to a minimum. 4. The pipe-work shall be protected from physical damage, and shall not be installed in an 2 unventilated space if the space is smaller than 4m . 5. The compliance with national gas regulations shall be observed. 6. The mechanical connections shall be accessible for maintenance purposes. 7. Follow the instructions given in this manual for handling, installing, cleaning, maintaining and disposing of the refrigerant. 8. Make sure ventilation openings clear of obstruction. 9. Notice : The servicing shall be performed only as recommended by the manufacturer. 10. Warning : The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation. 11. Warning : The appliance shall be stored in a room without continuously operating open flames (for example an operating gas appliance) and ignition sources (for example an operating electric heater). 12. The appliance shall be stored so as to prevent mechanical damage from occurring. 13. It is appropriate that anyone who is called upon to work on a refrigerant circuit should hold a valid and up-to-date certificate from an assessment authority accredited by the industry and recognizing their competence to handle refrigerants, in accordance with the assessment specification recognized in the industrial sector concerned. Service operations should only be carried out in accordance with the recommendations of the equipment manufacturer. Maintenance and repair operations that require the assistance of other qualified persons must be conducted under the supervision of the person competent for the use of flammable refrigerants. 14. Every working procedure that affects safety means shall only be carried out by competent persons. 15. Warning: * Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. * The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater). * Do not pierce or burn. * Be aware that refrigerants may not contain an odor. 15 Read technical manual Operating instructions Read operator ’ s manual Caution:Risk of fire EN 16 I n f orm a tion on se r vicing: 1 ) Chec k s t o the a r ea Prior t o beginning w ork on s y s t ems c o n t aining flammable r e fri g e r a n ts, s a f e ty chec k s a r e necessary t o ensu r e th a t the risk of ignition is minimi z ed. F or r epair t o the r e fri g e r a ting s y s t em, the f ollowing p r e c autions shall be c omplied with prior t o c onducting w ork on the s y s t em. 2 ) W ork p r ocedu r e W ork shall be under t a k en under a c o n t r olled p r ocedu r e so as t o minimi z e the risk of a flammable g as or v apor being p r ese n t while the w ork is being per f ormed. 3 ) Gene r al w ork a r ea All mai n t enance s t a f f and othe r s w orking in the lo c al a r ea shall be in s truc t ed on the n a tu r e of w ork being c arried out. W ork in c onfined spaces shall be a v oided. The a r ea a r ound the w or k space shall be sectioned o f f . Ensu r e th a t the c onditions within the a r ea h a v e been made s a f e by c o n t r ol of flammable m a t erial 4 ) Checking f or p r esence of r e fri g e r a n t The a r ea shall be chec k ed with an app r opri a t e r e fri g e r a n t d e t ec t or prior t o and during w ork, t o ensu r e the t echnician is a w a r e of po t e n tially flammable a tmosphe r es. Ensu r e th a t the leak d e t ection equipme n t being used is sui t able f or use with flammable r e fri g e r a n ts, i.e. non-sparkin g , adequ a t ely sealed or i n trinsi c ally s a f e. 5 ) P r esence of fi r e e xtinguisher If a n y hot w ork is t o be c onduc t ed on the r e fri g e r a tion equipme n t or a n y associ a t ed parts, app r opri a t e fi r e e xtinguishing equipme n t shall be a v ailable t o hand. H a v e a dry po w der or C O 2 fi r e e xtinguisher adjace n t t o the cha r ging a r ea. 6 ) No ignition sou r ces No pe r son c arrying out w ork in r el a tion t o a r e fri g e r a tion s y s t em which i n v ol v es e xposing a n y pipe w ork shall use a n y sou r ces of ignition in such a manner th a t it m a y lead t o the risk of fi r e or e xplosion. All possible ignition sou r ces, including ci g a r e t t e smokin g , should be k ept su f ficie n tly f ar a w a y f r om the si t e of in s t all a tion, r epairin g , r emoving and disposal, during which r e fri g e r a n t c an possibly be r eleased t o the sur r ounding space. Prior t o w ork t aking place, the a r ea a r ound the equipme n t is t o be su r v e y ed t o ma k e su r e th a t the r e a r e no flammable ha z a r ds or ignition ris k s. No Smoking signs shall be displ a y ed. 7 ) V e n til a t ed a r ea Ensu r e th a t the a r ea is in the open or th a t it is adequ a t ely v e n til a t ed b e f o r e b r eaking i n t o the s y s t em or c onducting a n y hot w ork. A deg r ee of v e n til a tion shall c o n tinue during the period th a t the w ork is c arried out. The v e n til a tion should s a f ely dispe r se a n y r eleased r e fri g e r a n t and p r e f e r ably e xpel it e x t ernally i n t o the a tmosphe r e. 8 ) Chec k s t o the r e fri g e r a tion equipme n t Whe r e electri c al c ompone n ts a r e being chan g ed, th e y shall be fit f or the purpose and t o the c or r ect specifi c a tion. A t all times the manu f actu r er's mai n t enance and se r vice guidelines shall be f ollo w ed. If in doubt c onsult the manu f actu r er's t echni c al departme n t f or assi s t ance. IN S TRU C TIONS F OR SE R VICING(R32) 16 EN The f ollowing chec k s shall be applied t o in s t all a tions using flammable r e fri g e r a n ts: -- The cha r g e si z e is in ac c o r dance with the r oom si z e within which the r e fri g e r a n t c o n t aining parts a r e in s t alled; -- The v e n til a tion machinery and outlets a r e ope r a ting adequ a t ely and a r e not ob s truc t ed; -- If an indi r ect r e fri g e r a ting ci r cuit is being used, the se c ondary ci r cuit shall be chec k ed f or the p r esence of r e fri g e r a n t; -- Marking t o the equipme n t c o n tinues t o be visible and legible. Markings and signs th a t a r e illegible shall be c or r ec t ed; -- R e fri g e r a tion pipe or c ompone n ts a r e in s t alled in a position whe r e th e y a r e unli k ely t o be e xposed t o a n y sub s t ance which m a y c or r ode r e fri g e r a n t c o n t aining c ompone n ts, unless the c ompone n ts a r e c on s truc t ed of m a t erials which a r e inhe r e n tly r esi s t a n t t o being c or r oded or a r e sui t ably p r o t ec t ed a g ain s t being so c or r oded. 9 ) Chec k s t o electri c al devices R epair and mai n t enance t o electri c al c ompone n ts shall include initial s a f e ty chec k s and c ompone n t inspection p r ocedu r es. If a f ault e xi s ts th a t c ould c omp r omise s a f e t y , then no electri c al supply shall be c onnec t ed t o the ci r cuit u n til it is s a ti s f ac t orily dealt with. If the f ault c annot be c or r ec t ed immedi a t ely but it is necessary t o c o n tinue ope r a tion, an adequ a t e t empo r ary solution shall be used. This shal l b e r epor t ed t o the owner of the equipme n t so all parties a r e advised. Initial s a f e ty chec k s shall include: -- Th a t c apaci t o r s a r e discha r g ed: this shall be done in a s a f e manner t o a v oid possibility of sparking; -- Th a t the r e no li v e electri c al c ompone n ts and wiring a r e e xposed while cha r gin g , r e c o v ering or pu r ging the s y s t em; -- Th a t the r e is c o n tinuity of earth bonding. 17. R epai r s t o sealed compone n ts 1 ) During r epai r s t o sealed c ompone n ts, all electri c al supplies shall be dis c onnec t ed f r om the equipme n t being w or k ed upon prior t o a n y r emo v al of sealed c o v e r s, e t c. If it is absolu t ely necessary t o h a v e an electri c al supply t o equipme n t during se r vicin g , then a permane n tly ope r a ting f orm of leak d e t ection shall be lo c a t ed a t the mo s t criti c al poi n t t o w arn of a po t e n tially ha z a r dous situ a tion. 2 ) P articular a t t e n tion shall be paid t o the f ollowing t o ensu r e th a t by w orking on electri c al c ompone n ts, the c asing is not al t e r ed in such a w a y th a t the le v el of p r o t ection is a f