AH AN AP AQ AR AS A1 A2 A3 A4 AG AJ AK AL AM A5 A6 AH A1 A2 A3 A4 A4 AN AP AQ AR AS AJ AK AL AM AG PAYSTATION 120 SEATS HIGH LEVEL SERVICES GANTRY - EXPOSED CHROME PIPEWORK ENTRANCE DK.1 PRODUCTION BUILDING DK.2 DK.3 WAREHOUSE FALLOW SPACE 0131 3 No. SUNKEN DOCKS @ +17.300 1 0539 2 0539 4 0539 W1 W2 W3 W4 W5 W6 W7 W8 W10 M1 M2 M3 M4 M5 M6 M7 M8 M9 WA WC WD WE WF MA MB MC MD ME MF MG MH MJ MK ML MM MN MP 18500 18500 18500 18500 18500 1824 0.2m2 VENT TO OPEN AIR 0.2m2 VENT TO OPEN AIR 70.1M (16.1M) EQUIPMENT ROOM 168 m2 SECURITY GATES TO FAIL SAFE OPEN PATH 15000 ROAD PATH 15000 ROAD (900) (900) (900) (900) (900) (900) (1100) (1100) (1100) (1100) (1100) (1100) (1100) (1100) (1100) (1100) (1100) (1100) (1100) (1100) (1200) (1200) (1100) (1100) (1800) (1100) (1200) (1100) (1100) (1600) (1100) (1500) (1840) (900) (900) (900) AIR SHAFT/ VOID 1 0563 2 0563 4 0563 DRLV DRLV DRLV DRLV DRLV DRLV DRLV DRLV (1800) (1050) (900) (1800) (3600) W9 WB WG R21 R22 R23 RA RB RC RD RE RF PLANT RM 01 62 m² DK1-1009 MEETING/TRAINING 01 156 m² DK1-1007 MEETING/TRAINING 02 156 m² DK1-1008 CORRIDOR 01 9 m² DK1-1013 ATRIUM STORE 16 m² DK1-1014 STAIR 01 LOBBY 13 m² DK1-1010 STAIR 01 23 m² DK1-1011 MEETING RM 01 60 m² DK1-1005 MEETING RM 02 23 m² DK1-1004 FEMALE WC 25 m² DK1-1016 MALE WC 26 m² DK1-1018 UA WC 7 m² DK1-1022 CL.STORE 5 m² DK1-1021 CONTINGENCY / FALLOW SPACE 95 m² DK1-1030 SECURITY CENTRE 27 m² DK1-1028 KITCHEN BY SPECIALIST 146 m² DK1-1033 PLANT RM 02 63 m² DK1-1046 LV SWITCHROOM 41 m² DK1-1048 STAIR 02 21 m² DK1-1045 STAIR 02 LOBBY 7 m² DK1-1044 DRYING RM 18 m² DK1-1041 MALE CHANGING RM/SHOWERS 30 m² DK1-1038 FEMALE CHANGING RM/SHOWERS 30 m² DK1-1040 BICYCLE STORE 57 m² DK1-1055 RECEPTION 256 m² DK1-1001 ENTRANCE/CHINESE WINTER GARDEN 153 m² DK1-1003 MULTI HEIGHT SPACE 797 m² DK1-1023 DELIVERY YARD 255 m² DK1-1053 LAB STAFF LOCKERS 62 m² DK1-1029 WC LOBBY 6 m² DK1-1015 ELEC. RISER 11 m² DK1-1012 ELEC. RISER 18 m² DK1-1043 TRANSFORMER 20 m² DK1-1050 SECURITY STORE 20 m² DK1-1054 LIFT 7 (GOODS) 15 m² DK1-1025 CANTEEN 266 m² DK1-1031 FOYER 61 m² DK1-1006 DELIVERIES 23 m² DK1-1042 STAFF WC 4 m² DK1-1066 HV SWITCHROOM 20 m² DK1-1051 GENERATOR 29 m² DK1-1052 GAS STORAGE 10 m² DK1-1049 ENTRANCE/CHINESE WINTER GARDEN 282 m² DK1-1002 FIRST AID 6 m² DK1-1020 SERVERY 84 m² DK1-1032 FITNESS ROOM 47 m² DK1-1034 LOBBY 26 m² DK1-1037 ICT COMMS ROOM 14 m² DK1-1019 CORRIDOR 23 m² DK1-1047 LIFT 8 4 m² DK1-1026 LIFT 9 4 m² DK1-1027 LIFT 6 (GOODS) 10 m² DK1-1024 ACCESS CORRIDOR 195 m² DK1-1059 WASTE/RE-CYCLING 18 m² DK1-1056 STAFF SHOWER 3 m² DK1-1065 CLEANERS ST 5 m² DK1-1063 WC 4 m² DK1-1064 AIS COMMS ROOM 12 m² DK1-1035 ICT COMMS ROOM 12 m² DK1-1036 STAIR 01 21.04 m² 1 WC LOBBY 3.73 m² 2 TECHNICAL SPACE 683 m² 1012 CLEAN UTILITIES 308 m² 1030 PAL IN 5 m² 1118 COLD ROOM 104 m² 1136 CLEAN STAGING 26 m² 1170 PAL IN 5 m² 1178 W ASH 24 m² 1106 JC 4 m² 1132 MAL IN 7 m² 1124 MAL IN 6 m² 1156 PAL OUT 7 m² 1102 MAL IN 7 m² 1154 CLEAN WASH 21 m² 1168 PAL IN 7 m² 1122 CORRIDOR 59 m² 1158 PAL IN 6 m² 1150 WASH 25 m² 1166 PAL OUT 5 m² 1144 CLEAN WASH 21 m² 1268 CLEAN STAGING 26 m² 1270 PAL IN 6 m² 1176 PAL IN 5 m² 1218 INCOMING CORRIDOR 25 m² 1212 COLD ROOM 105 m² 1236 WASH 23 m² 1206 CLEAN STAGING 36 m² 1234 MAL IN 7 m² 1224 WASH 25 m² 1266 MAL OUT 9 m² 1204 MAL IN 7 m² 1254 CORRIDOR 59 m² 1258 PAL IN 6 m² 1250 PAL IN 7 m² 1222 MATERIAL STAGING 220 m² 1042 WASTE OUT LOBBY 11 m² 1022 ELEV 8 m² E3 VESTIBULE 10 m² 1028 MACHINE ROOM 15 m² 1026 EXIT CORRIDOR 22 m² 1108 EXIT CORRIDOR 22 m² 1208 PROCESS WASTE COLLECTION ROOM 100 m² 1036 ELEV 10 m² E1 ELEV 9 m² E2 LOGISTICS CORRIDOR 791 m² 1010 MAL OUT 9 m² 1104 CLEAN WASH 22 m² 1130 CLEAN STAGING 36 m² 1134 PAL OUT 7 m² 1120 INCOMING CORRIDOR 25 m² 1112 ANTE ROOM 12 m² 1138 MAL OUT 6 m² 1148 PAL IN 5 m² 1152 PAL OUT 6 m² 1142 MAL OUT 7 m² 1146 MAL IN 6 m² 1174 MAL OUT 6 m² 1182 PAL OUT 5 m² 1186 MAL IN 7 m² 1172 PAL OUT 6 m² 1184 MAL OUT 7 m² 1180 MAL IN 6 m² 1256 PAL IN 5 m² 1252 PAL OUT 5 m² 1244 MAL OUT 6 m² 1248 PAL OUT 6 m² 1242 MAL OUT 7 m² 1246 ANTE ROOM 12 m² 1238 PAL OUT 7 m² 1220 CLEAN WASH 23 m² 1230 PAL OUT 7 m² 1202 MCC 17 m² 1018 AIS ROOM 21 m² 1020 MCC 24 m² 1016 AIS ROOM 23 m² 1014 WASTE SORTING ROOM 69 m² 1024 SAMPLE STAGING 17 m² 1044 ? ? ? MAL IN 10 m² 1068 MAL OUT 9 m² 1070 JC 5 m² 1072 PAL IN 7 m² 1074 PAL OUT 8 m² 1076 COLD ROOM 145 m² 1088 TEAM ROOM 62 m² 1080 CONSUMABLES STAGE 49 m² 1084 CORRIDOR 27 m² 1046 PAL 15 m² 1050 HAND WASH 14 m² 1048 PAL 13 m² 1056 PAL OUT 5 m² 1216 PAL OUT 5 m² 1116 CELL BANK ROOM 20 m² 1040 JC 4 m² 1232 JC 15 m² 1017 ? ? ? TRANSFORMER ROOM 12 m² 1032 TECH. SPACE 6 m² 1107 TECH. SPACE 5 m² 1133 TECH. SPACE 5 m² 1233 TECH. SPACE 6 m² 1207 TECH. SPACE 8 m² 1267 TECH. SPACE 12 m² 1269 TECH. SPACE 12 m² 1169 TECH. SPACE 8 m² 1167 BASE STORE 36 m² 1178 ACID STORE 38 m² 1180 TRANSFORMER 15 m² 1186 SWITCH ROOM 21 m² 1184 COLD ROOM 22 m² 1174 STORAGE 31 m² 1196 RAW MAT. LAB 42 m² 1164 MAL 10 m² 1160 PAL 5 m² 1158 PAL 6 m² 1154 MAL 7 m² 1150 SAMPLING 1 27 m² 1162 SAMPLING 2 28 m² 1156 MAL 57 m² 1130 WEIGH/DISPENSE (USP) 38 m² 1122 JC 22 m² 1116 PAL 14 m² 1118 MAL 9 m² 1120 MAL 9 m² 1132 PAL 12 m² 1134 SHIPPING PREP. 292 m² 1172 LOBBY 138 m² 1176 OFFICE 17 m² 1190 RECEIVING/DELIVERY 177 m² 1188 COLD STORAGE 2 166 m² 1106 COLD STORAGE 1 176 m² 1104 STAIRS 18 m² S1 WC 3 m² 1194 ELEVATOR 1 10 m² E1 ELEVATOR 2 10 m² E2 AIS ROOM 27 m² 1146 ENGINEERING STORE 163 m² 1110 WEIGH/DISPENSE (DISP) 47 m² 1136 LOCKER ROOM 42 m² 1108 CORRIDOR 185 m² 1114 WAREHOUSE 1386 m² 1102 PAL 6 m² 1152 MAL 7 m² 1148 MAL 10 m² 1166 MAL 9 m² 1112 W EIGH/DISPENSE 1 (USP) 21 m² 1124 W EIGH/DISPENSE 2 (USP) 21 m² 1126 W EIGH/DISPENSE 3 (USP) 23 m² 1128 JC 8 m² 1144 W EIGH/DISPENSE 1 (DISP) 34 m² 1138 W EIGH/DISPENSE 2 (DISP) 33 m² 1140 W EIGH/DISPENSE 3 (DISP) 34 m² 1142 DG STORE 24 m² 1182 STORAGE 9 m² 1170 CORRIDOR 52 m² 1107 CALIBRATION LAB 65 m² 1109 MALE W C 46 m² 04.002 FEMALE WC 51 m² 04.003 LOCKER 58 m² 04.004 LOCKER 51 m² 04.005 LIFT 11 m² 04.019 LIFT 11 m² 04.020 STAIR 05 27 m² ST-05 STAIR 06 27 m² ST-06 STAIR 01 25 m² ST-01 STAIR 02 24 m² ST-02 STAIR 03 24 m² ST-03 STAIR 04 24 m² ST-04 3 0563 (1500) FIRE SHUTTER (24.5M) 34.6M (24.6M) MA.1 WC LOBBY 6 m² BMS Room Garment Storage (1100) 28.2M (20.2m) 40.5M (19.5m) 42.1M (15.7m) 64.6M (20.6m) 58.4M (26.1m) 50.0M (34.7m) 59.7M (12.7m) 40.1M (9.7m) FIRE SHUTTER 58.4M (51.3m) 44.0M (51.4m) 1300 (24.4m) 62.9M (5.2M) 31.0M (29.0M) 57.2M (19.4M) 51.2M (37.7M) 43.9M (40.5M) 4800 (900) 59.1M 20.2M) AH AN AP AR AS A4 A6 A5 AJ AK AL AM A1.1 A1 A2 A3 AG AQ A6 A7 * FIRE SAFETY CERTIFICATE NOTES :- FIRE RESISTING WALL/PARTITION ACHIEVING 30 MINUTES FIRE RESISTANCE RATING (STABILITY, INTEGRITY AND INSULATION) IN ACCORDANCE WITH BS476: PART 8 /20-24. METHOD OF EXPOSURE AS SET OUT IN TABLE 24 OF BS 9999 2017. ANY UNINSULATED GLAZED ELEMENTS CONFINED TO THE LOCATIONS IDENTIFIED IN 31.3.2 AND TABLE 29 OF BS 9999:2017 EXCEPT IN THE CASE OF APARTMENTS WHERE THE LIMITS IN TABLE 1 OF BS5588 PART 1 : 1990 ARE TO APPLY INSTEAD. FIRE RATED WALLS/PARTITIONS TO BE EITHER (i) CARRIED UP ABOVE CEILING LEVEL OR DOWN BELOW RAISED ACCESS FLOORS TO THE SOFFIT/TOP OF THE FLOOR CONSTRUCTION OR THE ROOF SOFFIT LEVEL AS APPROPRIATE OR (ii) CAVITY BARRIERS ARE TO BE INSTALLED IN THE CEILING VOID OR UNDERFLOOR VOID ON THE LINE OF FIRE RATED PARTITIONS OR (III) CEILING IS TO BE CONSTRUCTED, THROUGHOUT THE COMPARTMENT, TO A SPECIFICATION ACHIEVING 30 MINUTES FIRE RESISTANCE RATING (INTEGRITY AND INSULATION) IN ACCORDANCE WITH ITEM 17 OF TABLE A1 OF TECHNICAL GUIDANCE DOCUMENT B. DESIGNATED CLEAR ESCAPE ROUTE FIRE SAFETY CERTIFICATE NOTES :- COMPARTMENT WALL/FLOOR ACHIEVING 240 MINUTES FIRE RESISTANCE RATING (STABILITY, INTEGRITY AND INSULATION) IN ACCORDANCE WITH BS 476: PART 8/20-24 (OR REI240 WHEN TESTED TO RELEVANT EUROPEAN STANDARD). METHOD OF EXPOSURE AS SET OUT IN TABLE 24 OF BS 9999 2017 AND IN THE CASE OF A WALL IS TO EXTEND FULL STOREY HEIGHT. COMPARTMENT WALL/FLOOR ACHIEVING 120 MINUTES FIRE RESISTANCE RATING (STABILITY, INTEGRITY AND INSULATION) IN ACCORDANCE WITH BS 476: PART 8/20-24 (OR REI120 WHEN TESTED TO RELEVANT EUROPEAN STANDARD). METHOD OF EXPOSURE AS SET OUT IN TABLE 24 OF BS 9999 2017 AND IN THE CASE OF A WALL IS TO EXTEND FULL STOREY HEIGHT. COMPARTMENT WALL/FLOOR ACHIEVING 90 MINUTES FIRE RESISTANCE RATING (STABILITY, INTEGRITY AND INSULATION) IN ACCORDANCE WITH BS 476: PART 8/20-24 (OR REI90 WHEN TESTED TO RELEVANT EUROPEAN STANDARD). METHOD OF EXPOSURE AS SET OUT IN TABLE 24 OF BS 9999 2017 AND IN THE CASE OF A WALL IS TO EXTEND FULL STOREY HEIGHT. COMPARTMENT WALL/FLOOR ACHIEVING 60 MINUTES FIRE RESISTANCE RATING (STABILITY, INTEGRITY AND INSULATION) IN ACCORDANCE WITH BS 476: PART 8/20-24 (OR REI60 WHEN TESTED TO RELEVANT EUROPEAN STANDARD). METHOD OF EXPOSURE AS SET OUT IN TABLE 24 OF BS 9999 2017 AND IN THE CASE OF A WALL IS TO EXTEND FULL STOREY HEIGHT. CONSTRUCTION TO ACHIEVE SMOKE RETARDING CONSTRUCTION, ANY GLAZING TO BE TOUGHENED GLASS FIRE SAFETY CERTIFICATE NOTES :- FIRE RESISTING DOORSET TO HAVE NOT LESS THAN 90 MINUTES INTEGRITY RATING IN ACCORDANCE WITH BS476: PART: 8/20-22 (OR E90 RATING WHEN TESTED IN ACCORDANCE WITH THE RELEVANT EUROPEAN STANDARD). THE DOORSET TO BE FITTED WITH COLD SMOKE SEALS ACHIEVING A LEAKAGE RATE NOT EXCEEDING 3M2/M/HOUR (HEAD AND JAMBS) WHEN TESTED AT 25PA UNDER BS 476: SECTION 31.1 OR ACHIEVE AN SA CLASSIFICATION WHEN TESTED TO I.S. EN 1634-3:2004. DOORSET TO BE FITTED WITH AN AUTOMATIC SELF-CLOSING DEVICE WHICH IS CAPABLE OF CLOSING THE DOOR FROM ANY ANGLE AND AGAINST ANY LATCH FITTED TO THE DOOR. FIRE RESISTING DOORSET TO HAVE NOT LESS THAN 60 MINUTES INTEGRITY RATING IN ACCORDANCE WITH BS476: PART: 8/20-22 (OR E60 RATING WHEN TESTED IN ACCORDANCE WITH THE RELEVANT EUROPEAN STANDARD). THE DOORSET TO BE FITTED WITH COLD SMOKE SEALS ACHIEVING A LEAKAGE RATE NOT EXCEEDING 3M2/M/HOUR (HEAD AND JAMBS) WHEN TESTED AT 25PA UNDER BS 476 : SECTION 31.1 OR ACHIEVE AN SA CLASSIFICATION WHEN TESTED TO I.S. EN 1634-3:2004. DOORSET TO BE FITTED WITH AN AUTOMATIC SELF-CLOSING DEVICE WHICH IS CAPABLE OF CLOSING THE DOOR FROM ANY ANGLE AND AGAINST ANY LATCH FITTED TO THE DOOR. FIRE RESISTING DOORSET TO HAVE NOT LESS THAN 30 MINUTES INTEGRITY RATING IN ACCORDANCE WITH BS476: PART: 8/20-22 (OR E30 RATING WHEN TESTED IN ACCORDANCE WITH THE RELEVANT EUROPEAN STANDARD). THE DOORSET TO BE FITTED WITH COLD SMOKE SEALS ACHIEVING A LEAKAGE RATE NOT EXCEEDING 3M2/M/HOUR (HEAD AND JAMBS) WHEN TESTED AT 25PA UNDER BS 476: SECTION 31.1 OR ACHIEVE AN SA CLASSIFICATION WHEN TESTED TO I.S. EN 1634-3:2004. DOORSET TO BE FITTED WITH AN AUTOMATIC SELF-CLOSING DEVICE WHICH IS CAPABLE OF CLOSING THE DOOR FROM ANY ANGLE AND AGAINST ANY LATCH FITTED TO THE DOOR. FIRE RESISTING LIFT LANDING DOOR ACHIEVING NOT LESS 60 MINUTES INTEGRITY RATING IN ACCORDANCE WITH BS476 : PART : 8/20-22. DISABLED REFUGE SPACE (MIN. 1400mm x 900mm) IN ACCORDANCE BS8300: PART 8. EMERGENCY VOICE COMMUNICATION TO BE PROVIDED WITH OUTSTATIONS AT EACH DISABLED REFUGE POINT IN ACCORDANCE WITH BS 5839 PART 9. FIRE SAFETY CERTIFICATE NOTES :- DIMENSIONS REFER TO: A) MINIMUM AGGREGATE OPENABLE CLEAR WIDTH OF DOORS, MEASURED FROM DOORSTOP TO PROJECTING DOOR IRONMONGERY; OR B) WIDTH OF CORRIDOR MEASURED BETWEEN FINISHED SURFACE OF WALLS OR OTHER-FIXED OBSTRUCTIONS (SUCH AS PROTRUDING COLUMNS) AT SHOULDER LEVEL, SUBJECT TO HANDRAILS NOT INTRUDING MORE THAN 100MM OR SKIRTINGS NOT INTRUDING MORE THAN 30MM INTO THE MEASURED WIDTH; C) CLEAR WIDTH OF STAIRWAY MEASURED BETWEEN WALLS OR BALUSTRADES SUBJECT TO HANDRAILS INTRUDING NOT MORE THAN 100MM OR STRINGERS NOT INTRUDING MORE THAN 30MM INTO THE CLEAR WIDTH.FIRE FIGHTING LIFT CONFORMING TO THE RELEVANT RECOMMENDATIONS OF BS 9999:2017 DESIGNATED EXITS / DIRECTION OF ESCAPE. TRAVEL DISTANCE ONE DIRECTION OF ESCAPE. TRAVEL DISTANCE. Y = TRAVEL DISTANCE TO EXIT (X = DEAD END DISTANCE) AUTOMATICALLY OPENING VENT HAVING A FREE AREA NOT LESS THAN 'X'm square. PERMANENT VENTILATION OUTLET HAVING A FREE AREA OF NOT LESS THAN 'X'm square. LANDING VALVE ON DRY RISING MAIN CONFORMING WITH BS5306 : PART 1 : 1988. :- FIRE HYDRANT CONFORMING WITH BS750 : 1984 SPECIFICATION FOR UNDERGROUND FIRE HYDRANTS AND SURFACE BOX FRAMES AND COVERS. FIRE AND SMOKE CURTAIN LINKED TO FIRE DETECTION AND ALARM SYSTEM TO ACHIEVE 60 MINUTES FIRE RESISTANCE INTEGRITY DRY RISER BREECHING INLET TO BE SHOWN AT GROUND FLOOR LEVEL. NOTES (1) THIS DRAWING IS TO BE READ IN CONJUNCTION WITH MICHAEL SLATTERY & ASSOCIATES COMPLIANCE REPORT. (2) IT IS NOTED THAT THIS DRAWING DOES NOT INDICATE THE FIRE PROTECTION OF SERVICE DUCTS. FOR THE OPTIONS IN RELATION TO SAME REFER SECTION 2.3 OF MICHAEL SLATTERY & ASSOCIATES COMPLIANCE REPORT. NOTWITHSTANDING THIS, GENERALLY SERVICES DUCTS WILL BE FIRE STOPPED AT HORIZONTAL FIRE COMPARTMENT ENCLOSURES, UNLESS INDICATED OTHERWISE ON THE DRAWINGS. (XXX) PV(x) AOV(x) DRLV H FLOOR (NEW COMPARTMENT) ACHIEVING 60 MINUTES FIRE RESISTANCE RATING IN ACCORDANE WITH BS 476 PART 8 / 20-24 ALL RAPID ROLLER DOORS ARE FAIL SAFE OPEN GRASSCRETE FIRE TRACK AUTOMATIC RR DOOR (FAILSAFE) PROCESS EQUIPMENT MOBILE EQUIPMENT Y (X) SMOKE STOP DOOR DRAWING 0529 1.5 01 02 2.5 03 ROOF 01 02 03 04 PLANT KEY SECTION RED LINE INDICTAES PLAN CUT LOCATION ACROSS DIFFERING LEVELS BETWEEN DK.1 AND DK.2 1.5 2.5 ROOF DK.2 DK.1 DK1 DK2 DK3 SITE PLAN NORTH DK4 5 6 7 8 9 10 11 12 A B C D E F G SCALE PROJECT TITLE DRAWING No. ALL DIMENSIONS IN (mm) UNLESS SPECIFIED OTHERWISE THE INFORMATION CONTAINED HEREIN MAY NOT BE USED OR REPRODUCED IN ANY MANNER WITHOUT WRITTEN PERMISSION OF INTEGRATED PROJECT SERVICES. CONFIDENTIAL 2nd Floor Block 43B, Parkwest Business Park, Dublin 12, D12 P5V6 IRELAND Ph: +353 (01) 4854246 www.ipsdb.com Integrated Project Services Engineering Design/Build Compliance Consulting Plotted on: AS INDICATED 1 2 3 4 H I J 5 6 7 8 9 10 11 12 1 2 3 4 A B C D E F G H I J 19 Merrion Square, Dublin 2, Ireland Tel: +353 1 6693000 Fax: +353 1 6613300 Email: 13094@stwarchitects.com Web: www.stwarchitects.com Scope House, Perrystown, Dublin 12 Tel: +353 (0)1 563 8342 Email: info@gdalyconsulting.com Web: www.gdalyconsulting.com 26/03/2019 17:38:43 WUXI IRELAND PHASE 1 DK.1 LEVEL 01, DK.2 & DK.3 LEVEL 01 - FSC FLOOR PLAN 18276-ADR-DK0-L1-0529 1 : 250 DK.1, DK.2, DK.3 LEVEL 01 - FSC FLOOR PLAN 1 AIR SHAFT / VOID AIR SHAFT / VOID Processing Area Processing Area Processing Area Processing Area REV DESCRIPTION DATE CHK BY APPR BY A ISSUED FOR FIRE CERTIFICATE APPLICATION 20/12/2018 RD PD B ISSUE FOR FIRE CERTIFICATE APPLICATION 02/01/2019 RD PD C ISSUE FOR FIRE CERT 01/03/2019 RD PD D ISSUE FOR FIRE CERT 22/03/2019 E ISSUE FOR FIRE CERT 26/03/2019 RD PD CI 7301 CI 4921 CI 4882 CI 4882 CI 7301 CI 7272 CI 7112 CI 7112 CI 7084 CI 4830 CI 4918 CI 4955 CI 4881 CI 2796