Medical Device Vigilance Regulatory affairs and post-market safety essentials Safety oversight continues after market entry → Real-world use can reveal malfunctions, design limitations, usability problems, and risks not fully visible during development. → Vigilance turns those signals into assessment, reporting, corrective action, and product improvement. 2 / 11 Vigilance is the incident-response layer of PMS THE BROADER SYSTEM Post-market surveillance The broader system for collecting and analysing device performance and safety information. THE FOCUSED PROCESS Vigilance The focused process for evaluating incidents and deciding whether reporting or corrective action is required. Both create a continuous feedback loop between field experience, risk evaluation, and lifecycle improvement. 3 / 11 Four activities make the system work Receive and log Complaints and safety information. Assess The event, potential harm, and reportability. Report and correct Qualifying events and corrective action. Monitor and follow up Trends and effectiveness. 4 / 11 Assessment starts with evidence and risk Evidence to assemble Actual or potential harm Device identifiers Malfunction or performance deterioration Intended use and instructions Similar prior events System readiness Document investigations in a proportionate, evidence-based way. Define responsibilities, escalation routes, and documentation requirements before an incident occurs. 5 / 11 Reporting deadlines are jurisdiction-specific Reporting windows vary by jurisdiction and event severity. 0 5 10 15 20 25 30 Timeline EU MDR serious incident EU serious public health t... EU death or unanticipated... US FDA MDR US remedial-action case Requirement 15 2 10 30 5 Use the market- specific rule EU MDR: qualifying serious incidents and field safety corrective actions follow Article 87 timelines. United States: FDA MDR manufacturer reports are generally due within 30 calendar days of awareness; certain remedial-action cases may require reporting within 5 work days. Use market-specific procedures rather than applying one jurisdiction’s rules universally. 6 / 11 Vigilance is a cross- functional operating system Regulatory affairs, quality, clinical, engineering, customer support, distributors, importers, and local market teams all contribute signals or decisions. A complaint received by one department may trigger a regulatory assessment elsewhere. Training helps teams recognise potential safety signals early. Field signals become quality and regulatory decisions. 7 / 11 Trend monitoring turns repeated complaints into signals Not every complaint requires an individual serious-incident report. Repeated non-serious events can indicate an emerging safety concern. Trend analysis supports further investigation, preventive action, and corrective-action effectiveness reviews. Repeated non- serious events Emerging safety concern Further investigation Preventive action Corrective-action effectiveness reviews 8 / 11 Build vigilance into the quality system Written procedures for intake, triage, investigation, escalation, and submission approval. Traceable records , evidence, decision rationales, access controls, and retention practices. Connected documentation linking vigilance findings to risk management and PMS documentation. Audits and process reviews to identify delays, incomplete records, and inconsistent reportability decisions. 9 / 11 Strong vigilance protects patients and strengthens oversight Timely action reduces the likelihood of repeated harm. Reliable records demonstrate continued oversight of device safety and performance. Continuous review keeps regulatory decisions connected to real-world evidence. Oversight remains connected to real-world device use. 10 / 11 Partner with DDReg Pharma for Medical Device Vigilance Medical Device Vigilance Explore Our Services → Global Life Sciences Regulatory Consulting Partner Explore Global Life Sciences Regulatory → Contact-us Get in Touch → 11 / 11